These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

79 related articles for article (PubMed ID: 16422074)

  • 1. [Design of a quantitative analysis software system for myocardial contrast echocardiography].
    Sun F; Zhang M; Yao G; Song H; Liu L; Zhang Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Dec; 22(6):1095-9. PubMed ID: 16422074
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Development of a new MCE-based quantitative analysis system for myocardial microcirculation].
    Zhang M; Sun F; Yao G
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Jun; 25(3):708-11, 715. PubMed ID: 18693461
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical application of harmonic power Doppler imaging in the assessment of myocardial perfusion by contrast echocardiography.
    Belcik JT; Bierig SM; Chadwell K; Roberts B
    J Am Soc Echocardiogr; 2005 Oct; 18(10):1083-92. PubMed ID: 16198886
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Combination of contrast with stress echocardiography: a practical guide to methods and interpretation.
    Moir S; Marwick TH
    Cardiovasc Ultrasound; 2004 Aug; 2():15. PubMed ID: 15331015
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study.
    Senior R; Moreo A; Gaibazzi N; Agati L; Tiemann K; Shivalkar B; von Bardeleben S; Galiuto L; Lardoux H; Trocino G; Carrió I; Le Guludec D; Sambuceti G; Becher H; Colonna P; Ten Cate F; Bramucci E; Cohen A; Bezante G; Aggeli C; Kasprzak JD
    J Am Coll Cardiol; 2013 Oct; 62(15):1353-61. PubMed ID: 23770168
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of two- versus three-dimensional myocardial contrast echocardiography for assessing subendocardial perfusion abnormality after percutaneous coronary intervention in patients with acute myocardial infarction.
    Iwakura K; Ito H; Okamura A; Kurotobi T; Koyama Y; Date M; Inoue K; Nagai H; Imai M; Arita Y; Toyoshima Y; Ozawa M; Fujii K
    Am J Cardiol; 2007 Nov; 100(10):1502-10. PubMed ID: 17996509
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Extracting endocardial borders from sequential echocardiographic images.
    Choy MM; Jin JS
    IEEE Eng Med Biol Mag; 1998; 17(1):116-21. PubMed ID: 9460627
    [No Abstract]   [Full Text] [Related]  

  • 8. Numerical methods and workstation for the quantitative analysis of real-time myocardial contrast echocardiography.
    Sun FR; Zhang MQ; Jia XB; Wang XJ; Yao GH; Zhang Y
    IEEE Trans Inf Technol Biomed; 2010 Sep; 14(5):1204-10. PubMed ID: 20129869
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Italian Society of Cardiovascular Echography (SIEC) Consensus Conference on the state of the art of contrast echocardiography.
    Ital Heart J; 2004 Apr; 5(4):309-34. PubMed ID: 15185894
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-resolution myocardial perfusion imaging in mice with high-frequency echocardiographic detection of a depot contrast agent.
    Kaufmann BA; Lankford M; Behm CZ; French BA; Klibanov AL; Xu Y; Lindner JR
    J Am Soc Echocardiogr; 2007 Feb; 20(2):136-43. PubMed ID: 17275698
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrected quantification method to determine myocardial blood flow using real-time myocardial contrast echocardiography.
    Otani K; Masuda K; Asanuma T; Ishikura F; Beppu S
    J Am Soc Echocardiogr; 2006 Aug; 19(8):973-81. PubMed ID: 16880091
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantitative analysis of myocardial perfusion in rats by contrast echocardiography.
    Thibault H; Lafitte S; Timperley J; Tariosse L; Becher H; Roudaut R; Dos Santos P
    J Am Soc Echocardiogr; 2005 Dec; 18(12):1321-8. PubMed ID: 16376761
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Analysis of the quantitative improvements in resting echocardiographic image sharpness through the use of contrast enhanced echocardiography.
    Glassy MS; Groves EM
    Int J Cardiovasc Imaging; 2014 Jun; 30(5):867-73. PubMed ID: 24647916
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prediction of transmural extent of infarction with contrast echocardiographically derived index of myocardial blood flow and myocardial blood volume fraction: comparison with contrast-enhanced magnetic resonance imaging.
    Choi EY; Seo HS; Park S; Kim HJ; Ahn JA; Ko YG; Choi BW; Kang SM; Choi D; Ha JW; Rim SJ; Jang Y; Chung N
    J Am Soc Echocardiogr; 2006 Oct; 19(10):1211-9. PubMed ID: 17000359
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Usefulness of parametric imaging-based quantitative myocardial contrast echocardiography in predicting the functional recovery of akinetic segments following primary angioplasty in acute myocardial infarction patients].
    Serra V; Pérez de Isla L; Zamorano J; Almería C; Rodrigo JL; Pérez M; Florit J; Azcona L; Hernández RA; Macaya C
    Rev Esp Cardiol; 2005 Jun; 58(6):649-56. PubMed ID: 15970120
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Investigating the significance of multiple scattering in ultrasound contrast agent particle populations.
    Stride E; Saffari N
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2332-45. PubMed ID: 16463501
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Color encoding of endocardial motion improves the interpretation of contrast-enhanced echocardiographic stress tests by less-experienced readers.
    Mor-Avi V; Jacobs LD; Weiss RJ; Sugeng L; Weinert L; Bouchard T; Spencer KT; Lang RM
    J Am Soc Echocardiogr; 2006 Jan; 19(1):48-54. PubMed ID: 16423669
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The quantification of absolute myocardial perfusion in humans by contrast echocardiography: algorithm and validation.
    Vogel R; Indermühle A; Reinhardt J; Meier P; Siegrist PT; Namdar M; Kaufmann PA; Seiler C
    J Am Coll Cardiol; 2005 Mar; 45(5):754-62. PubMed ID: 15734622
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Myocardial contrast echocardiography for assessment of myocardial perfusion at rest in a patient with left main coronary artery stenosis.
    Hagendorff A; Pfeiffer D; Rother T; Becher H
    Z Kardiol; 2003 Oct; 92(10):876-83. PubMed ID: 14579053
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative parameters of myocardial perfusion with contrast echocardiography in human beings: Influence of triggering mode.
    Aggeli CJ; Shimoni S; Nagueh SF; Zoghbi WA
    J Am Soc Echocardiogr; 2002 Dec; 15(12):1432-9. PubMed ID: 12464908
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.