BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

628 related articles for article (PubMed ID: 16426667)

  • 1. A new plastic collection tube made of polyethylene terephtalate is suitable for monitoring traditional anticoagulant therapy (oral anticoagulant, unfractionated heparin, and low molecular weight heparin).
    Toulon P; Ajzenberg N; Smahi M; Guillin MC
    Thromb Res; 2007; 119(2):135-43. PubMed ID: 16426667
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multicenter evaluation of a bilayer polymer blood collection tube for coagulation testing: effect on routine hemostasis test results and on plasma levels of coagulation activation markers.
    Toulon P; Aillaud MF; Arnoux D; Boissier E; Borg JY; Gourmel C
    Blood Coagul Fibrinolysis; 2006 Nov; 17(8):625-31. PubMed ID: 17102648
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison between siliconized evacuated glass and plastic blood collection tubes for prothrombin time and activated partial thromboplastin time assay in normal patients, patients on oral anticoagulant therapy and patients with unfractioned heparin therapy.
    D'Angelo G; Villa C
    Int J Lab Hematol; 2011 Apr; 33(2):219-25. PubMed ID: 20979595
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Underestimation of unfractionated heparin therapy assessment due to platelet activation when using partial-draw (pediatric) citrate collection tubes.
    Desconclois C; Eschwège V; Proulle V; Boutekedjiret T; Dreyfus M; Toulon P
    Thromb Res; 2014 Nov; 134(5):1117-22. PubMed ID: 25248688
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of samples obtained from 3.2% sodium citrate glass and two 3.2% sodium citrate plastic blood collection tubes used in coagulation testing.
    Gosselin RC; Janatpour K; Larkin EC; Lee YP; Owings JT
    Am J Clin Pathol; 2004 Dec; 122(6):843-8. PubMed ID: 15539376
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinically relevant differences in prothrombin time and INR values related to blood sample collection in plastic vs glass tubes.
    Fiebig EW; Etzell JE; Ng VL
    Am J Clin Pathol; 2005 Dec; 124(6):902-9. PubMed ID: 16416740
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Plastic versus siliconized glass tubes: evaluation in current laboratory practice.
    Biron-Andréani C; Mallol C; Séguret F; Schved JF
    Thromb Haemost; 2000 May; 83(5):800-1. PubMed ID: 10823290
    [No Abstract]   [Full Text] [Related]  

  • 8. Standardization of coagulation tests.
    Opartkiattikul N
    Southeast Asian J Trop Med Public Health; 1999; 30 Suppl 3():79-85. PubMed ID: 10926265
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of drawing a discard tube on PT and APTT results in healthy adults.
    Bamberg R; Cottle JN; Williams JC
    Clin Lab Sci; 2003; 16(1):16-9. PubMed ID: 12587654
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Anticoagulation monitoring part 2: Unfractionated heparin and low-molecular-weight heparin.
    Spinler SA; Wittkowsky AK; Nutescu EA; Smythe MA
    Ann Pharmacother; 2005; 39(7-8):1275-85. PubMed ID: 15956240
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The use of evacuated tubes for blood collection in oral anticoagulant control.
    van den Besselaar AM; van Halem-Visser LP; Loeliger EA
    Thromb Haemost; 1983 Oct; 50(3):676-7. PubMed ID: 6648890
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of EDTA samples for prothrombin time measurement in patients receiving oral anticoagulants.
    Horsti J
    Haematologica; 2001 Aug; 86(8):851-5. PubMed ID: 11522542
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hemostasis test compatibility with capped and uncapped tubes.
    Finnegan K; Cutsforth G
    Clin Lab Sci; 2011; 24(4):215-20. PubMed ID: 22288219
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Antithrombotic and anticoagulant activity of depolymerized fragment of the glycosaminoglycan extracted from Stichopus japonicus Selenka.
    Suzuki N; Kitazato K; Takamatsu J; Saito H
    Thromb Haemost; 1991 Apr; 65(4):369-73. PubMed ID: 1647552
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Difference in examination of coagulation function in heparin anticoagulant therapy between point of care tests and automatic coagulation analyzer].
    Li J; Cong YL; Tu GH; Yang L; Zhu BB; Jin L
    Zhonghua Yi Xue Za Zhi; 2007 May; 87(18):1269-71. PubMed ID: 17686264
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of pre-analytical variables on the anti-activated factor X chromogenic assay when monitoring unfractionated heparin and low molecular weight heparin anticoagulation.
    McGlasson DL; Kaczor DA; Krasuski RA; Campbell CL; Kostur MR; Adinaro JT
    Blood Coagul Fibrinolysis; 2005 Apr; 16(3):173-6. PubMed ID: 15795534
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A low volume specimen container suitable for monitoring the aPTT of heparinized patients.
    Ray MJ; Carroll PA; Just SJ; Hawson GA
    Blood Coagul Fibrinolysis; 1993 Oct; 4(5):805-7. PubMed ID: 8292732
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Unsuitability of evacuated tubes for monitoring heparin therapy by activated partial thromboplastin time.
    Heyns AD; van den Berg DJ; Kleynhans PH; du Toit PW
    J Clin Pathol; 1981 Jan; 34(1):63-8. PubMed ID: 7462439
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of a new generation of plastic evacuated blood-collection tubes in clinical chemistry, therapeutic drug monitoring, hormone and trace metal analysis.
    Boeynaems JM; De Leener A; Dessars B; Villa-Lobos HR; Aubry JC; Cotton F; Thiry P
    Clin Chem Lab Med; 2004 Jan; 42(1):67-71. PubMed ID: 15061383
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of glass K3EDTA versus plastic K2EDTA blood-drawing tubes for complete blood counts, reticulocyte counts, and white blood cell differentials.
    Van Cott EM; Lewandrowski KB; Patel S; Grzybek DY; Patel HS; Fletcher SR; Kratz A
    Lab Hematol; 2003; 9(1):10-4. PubMed ID: 12661823
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 32.