These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

341 related articles for article (PubMed ID: 16429699)

  • 21. An In Vitro Evaluation of the Loosening of Different Interchangeable Abutments in Internal-Connection-Type Implants.
    Park JM; Baek CH; Heo SJ; Kim SK; Koak JY; Kim SK; Belser UC
    Int J Oral Maxillofac Implants; 2017; 32(2):350-355. PubMed ID: 28291853
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The behavior of a zirconia or metal abutment on the implant-abutment interface during cyclic loading.
    Queiroz DA; Hagee N; Lee DJ; Zheng F
    J Prosthet Dent; 2020 Aug; 124(2):211-216. PubMed ID: 31810616
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Vertical Misfit of Single-Implant Abutments Made from Different Materials Under Cyclic Loading.
    Butignon LE; de Almeida Basílio M; Santo JS; Arioli Filho JN
    Int J Oral Maxillofac Implants; 2016; 31(5):1017-22. PubMed ID: 27632255
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of cyclic loading on reverse torque values of angled screw channel systems.
    Mulla SH; Seghi RR; Johnston WM; Yilmaz B
    J Prosthet Dent; 2022 Sep; 128(3):458-466. PubMed ID: 33612334
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Parameters determining micromotion at the implant-abutment interface.
    Karl M; Taylor TD
    Int J Oral Maxillofac Implants; 2014; 29(6):1338-47. PubMed ID: 25397796
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Screw loosening with interchangeable abutments in internally connected implants after cyclic loading.
    Kim SK; Koak JY; Heo SJ; Taylor TD; Ryoo S; Lee SY
    Int J Oral Maxillofac Implants; 2012; 27(1):42-7. PubMed ID: 22299077
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Influence of occlusal forces on stress distribution in preloaded dental implant screws.
    Alkan I; Sertgöz A; Ekici B
    J Prosthet Dent; 2004 Apr; 91(4):319-25. PubMed ID: 15116032
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of fatigue loading on the screw joint stability of zirconium abutment.
    Tsumita M; Kokubo Y; Kano T; Sasaki K
    J Prosthodont Res; 2013 Jul; 57(3):219-23. PubMed ID: 23796911
    [TBL] [Abstract][Full Text] [Related]  

  • 29. In vitro assessment of three types of zirconia implant abutments under static load.
    Kim JS; Raigrodski AJ; Flinn BD; Rubenstein JE; Chung KH; Mancl LA
    J Prosthet Dent; 2013 Apr; 109(4):255-63. PubMed ID: 23566607
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Experimental research on the relationship between fit accuracy and fracture resistance of zirconia abutments.
    Sui X; Wei H; Wang D; Han Y; Deng J; Wang Y; Wang J; Yang J
    J Dent; 2014 Oct; 42(10):1353-9. PubMed ID: 24561040
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Displacement and performance of abutments in narrow-diameter implants with different internal connections.
    Jacobs N; Seghi R; Johnston WM; Yilmaz B
    J Prosthet Dent; 2022 Jan; 127(1):100-106. PubMed ID: 33413986
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The implant-abutment interface of alumina and zirconia abutments.
    Yüzügüllü B; Avci M
    Clin Implant Dent Relat Res; 2008 May; 10(2):113-21. PubMed ID: 18218054
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Wear at the titanium-zirconia implant-abutment interface: a pilot study.
    Klotz MW; Taylor TD; Goldberg AJ
    Int J Oral Maxillofac Implants; 2011; 26(5):970-5. PubMed ID: 22010078
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The Effects of a Vertical Compressive Cyclic Load on Abutment Screws and the Stability of the Prosthesis in Nonengaging and Partially Engaging Abutments in a Screw-Retained Splinted Fixed Dental Prosthesis.
    Kwan JC; Kwan N
    Int J Oral Maxillofac Implants; 2022; 37(3):571-578. PubMed ID: 35727250
    [TBL] [Abstract][Full Text] [Related]  

  • 35. In vitro assessment of PEEK and titanium implant abutments: Screw loosening and microleakage evaluations under dynamic mechanical testing.
    Ortega-Martínez J; Delgado LM; Ortiz-Hernández M; Punset M; Cano-Batalla J; Cayon MR; Cabratosa-Termes J
    J Prosthet Dent; 2022 Mar; 127(3):470-476. PubMed ID: 33309211
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants.
    Hoyer SA; Stanford CM; Buranadham S; Fridrich T; Wagner J; Gratton D
    J Prosthet Dent; 2001 Jun; 85(6):599-607. PubMed ID: 11404760
    [TBL] [Abstract][Full Text] [Related]  

  • 37. In vitro performance of zirconia and titanium implant/abutment systems for anterior application.
    Rosentritt M; Hagemann A; Hahnel S; Behr M; Preis V
    J Dent; 2014 Aug; 42(8):1019-26. PubMed ID: 24699071
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Influence of three types of abutments on preload values before and after cyclic loading with structural analysis by scanning electron microscopy.
    Butignon LE; Basilio Mde A; Pereira Rde P; Arioli Filho JN
    Int J Oral Maxillofac Implants; 2013; 28(3):e161-70. PubMed ID: 23748335
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effects of tightening torque on screw stress and formation of implant-abutment microgaps: A finite element analysis.
    Honório Tonin BS; He Y; Ye N; Chew HP; Fok A
    J Prosthet Dent; 2022 Jun; 127(6):882-889. PubMed ID: 33472752
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging.
    Mühlemann S; Truninger TC; Stawarczyk B; Hämmerle CH; Sailer I
    Clin Oral Implants Res; 2014 Jan; 25(1):74-81. PubMed ID: 23735182
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.