These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 16429781)

  • 21. High-performance liquid chromatography followed by peroxyoxalate chemiluminescence detection of acetylcholine and choline utilizing immobilized enzymes.
    Honda K; Miyaguchi K; Nishino H; Tanaka H; Yao T; Imai K
    Anal Biochem; 1986 Feb; 153(1):50-3. PubMed ID: 3516007
    [TBL] [Abstract][Full Text] [Related]  

  • 22. ZnO nanoparticles as an oxidase mimic-mediated flow-injection chemiluminescence system for sensitive determination of carvedilol.
    Biparva P; Abedirad SM; Kazemi SY
    Talanta; 2014 Dec; 130():116-21. PubMed ID: 25159387
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A chemiluminometric method for the determination of urea in serum using a three-enzyme bioreactor.
    Tabata M; Murachi T
    J Biolumin Chemilumin; 1988; 2(2):63-7. PubMed ID: 3213592
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Plant tissue-based chemiluminescence flow biosensor for determination of unbound dopamine in rabbit blood with on-line microdialysis sampling.
    Li B; Zhang Z; Jin Y
    Biosens Bioelectron; 2002 Jun; 17(6-7):585-9. PubMed ID: 11959481
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Determination of L-glutamate using flow injection analysis with immobilized L-glutamate oxidase reactor.
    Li Q; Ye B; Zhang S; Yu J
    Chin J Biotechnol; 1994; 10(4):291-7. PubMed ID: 7780026
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Chemiluminescent assays for choline and phospholipase-D using a flow injection system.
    Yaqoob M; Nabi A; Masoom-Yasinzai M
    J Biolumin Chemilumin; 1997; 12(3):135-40. PubMed ID: 9427112
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Flow injection chemiluminescence immunoassay for 17beta-estradiol using an immunoaffinity column.
    Wang S; Lin S; Du L; Zhuang H
    Anal Bioanal Chem; 2006 Mar; 384(5):1186-90. PubMed ID: 16479371
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Flow injection chemiluminescent assays for glycerol and triglycerides using a co-immobilized enzyme reactor.
    Yaqoob M; Nabi A
    Luminescence; 2003; 18(2):67-71. PubMed ID: 12687625
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Determination of hydrogen peroxide by micro-flow injection-chemiluminescence using a coupled flow cell reactor chemiluminometer.
    Nozaki O; Kawamoto H
    Luminescence; 2000; 15(3):137-42. PubMed ID: 10862141
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Flow injection chemiluminescence immunoassay of microcystin-LR by using PEI-modified magnetic beads as capturer and HRP-functionalized silica nanoparticles as signal amplifier.
    Lu J; Wei W; Yin L; Pu Y; Liu S
    Analyst; 2013 Mar; 138(5):1483-9. PubMed ID: 23330150
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Simultaneous determination of glucose and 1-deoxyglucose in serum by anion-exchange chromatography with an immobilized pyranose oxidase reactor.
    Kiba N; Goto Y; Furusawa M
    J Chromatogr; 1993 Oct; 620(1):9-13. PubMed ID: 8106597
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Automatic flow procedure for the determination of ethanol in wine exploiting multicommutation and enzymatic reaction with detection by chemiluminescence.
    Fernandes EN; Reis BF
    J AOAC Int; 2004; 87(4):920-6. PubMed ID: 15295886
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Flow injection-chemiluminescence determination of acyclovir.
    Long X; Chen F
    Luminescence; 2012; 27(6):478-81. PubMed ID: 22223601
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A chemiluminometric method for NADPH and NADH using a two-enzyme bioreactor and its application to the determination of magnesium in serum.
    Tabata M; Totani M; Murachi T
    Biomed Chromatogr; 1990 May; 4(3):123-7. PubMed ID: 2383694
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Quantitation of glycerophosphorylcholine by flow injection analysis using immobilized enzymes.
    Mancini A; Del Rosso F; Roberti R; Caligiana P; Vecchini A; Binaglia L
    Mol Cell Biochem; 1996 Sep; 162(2):83-7. PubMed ID: 8905629
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Flow injection determination of choline in milk hydrolysates by an immobilized enzyme reactor coupled to a selective hydrogen peroxide amperometric sensor.
    Pati S; Quinto M; Palmisano F
    Anal Chim Acta; 2007 Jul; 594(2):234-9. PubMed ID: 17586120
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Flow injection system with chemiluminometric detection for enzymatic determination of ascorbic acid.
    Dãnet AF; Badea M; Aboul-Enein HY
    Luminescence; 2000; 15(5):305-9. PubMed ID: 11038488
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Determination of free cholesterol based on a novel flow-injection chemiluminescence method by immobilizing enzyme.
    Hu Y; Zhang Z
    Luminescence; 2008; 23(5):338-43. PubMed ID: 18500700
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Highly sensitive determination of diclofenac based on resin beads and a novel polyclonal antibody by using flow injection chemiluminescence competitive immunoassay.
    Shi J; Xu M; Tang Q; Zhao K; Deng A; Li J
    Spectrochim Acta A Mol Biomol Spectrosc; 2018 Feb; 191():1-7. PubMed ID: 28965083
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Sensitive determination of 2-methoxyestradiol in pharmaceutical preparations and serum samples using flow injection chemiluminescence.
    Yao H; Zhang M; Zeng W; Zeng X; Zhang Z
    Luminescence; 2014 May; 29(3):261-5. PubMed ID: 23836511
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.