65 related articles for article (PubMed ID: 1643228)
1. Template matching techniques for electrophysiologic signals: a practical, real-time system for detection of ventricular tachycardia.
Greenhut SE; Steinhaus BM
Biomed Sci Instrum; 1992; 28():37-42. PubMed ID: 1643228
[TBL] [Abstract][Full Text] [Related]
2. Separation of ventricular tachycardia from sinus rhythm using a practical, real-time template matching computer system.
Greenhut SE; Deering TF; Steinhaus BM; Ingram JL; Camp SR; DiCarlo LA
Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):2146-53. PubMed ID: 1279616
[TBL] [Abstract][Full Text] [Related]
3. A comparison of four new time-domain techniques for discriminating monomorphic ventricular tachycardia from sinus rhythm using ventricular waveform morphology.
Throne RD; Jenkins JM; DiCarlo LA
IEEE Trans Biomed Eng; 1991 Jun; 38(6):561-70. PubMed ID: 1879845
[TBL] [Abstract][Full Text] [Related]
4. Detection of cardiac tachyarrhythmias in implantable devices.
Gillberg J
J Electrocardiol; 2007; 40(6 Suppl):S123-8. PubMed ID: 17993309
[TBL] [Abstract][Full Text] [Related]
5. Improving contemporary algorithms for implantable cardioverter-defibrillator function.
Shome S; Li D; Thompson J; McCabe A
J Electrocardiol; 2010; 43(6):503-8. PubMed ID: 20719333
[TBL] [Abstract][Full Text] [Related]
6. Implantable cardioverter defibrillator algorithms: status review in terms of computational cost.
Cebrián A; Millet J; Castells F
Biomed Tech (Berl); 2007 Feb; 52(1):25-30. PubMed ID: 17313330
[TBL] [Abstract][Full Text] [Related]
7. Efficient algorithms for detecting changes in intraventricular electrogram morphology.
Throne RD
Biomed Sci Instrum; 1994; 30():15-20. PubMed ID: 7948628
[TBL] [Abstract][Full Text] [Related]
8. Continuous template collection and updating for electrogram morphology discrimination in implantable cardioverter defibrillators.
Compton SJ; Merrill JJ; Dorian P; Cao J; Zhou D; Gillberg JM;
Pacing Clin Electrophysiol; 2006 Mar; 29(3):244-54. PubMed ID: 16606391
[TBL] [Abstract][Full Text] [Related]
9. Sensitivity and specificity of an automated external defibrillator algorithm designed for pediatric patients.
Atkins DL; Scott WA; Blaufox AD; Law IH; Dick M; Geheb F; Sobh J; Brewer JE
Resuscitation; 2008 Feb; 76(2):168-74. PubMed ID: 17765384
[TBL] [Abstract][Full Text] [Related]
10. Dual-chamber versus single-chamber detection enhancements for implantable defibrillator rhythm diagnosis: the detect supraventricular tachycardia study.
Friedman PA; McClelland RL; Bamlet WR; Acosta H; Kessler D; Munger TM; Kavesh NG; Wood M; Daoud E; Massumi A; Schuger C; Shorofsky S; Wilkoff B; Glikson M
Circulation; 2006 Jun; 113(25):2871-9. PubMed ID: 16769912
[TBL] [Abstract][Full Text] [Related]
11. Arrhythmia detection in single- and dual-chamber implantable cardioverter defibrillators: the more leads, the better?
Francia P; Balla C; Uccellini A; Cappato R
J Cardiovasc Electrophysiol; 2009 Sep; 20(9):1077-82. PubMed ID: 19500231
[TBL] [Abstract][Full Text] [Related]
12. Improving SVT discrimination in single-chamber ICDs: a new electrogram morphology-based algorithm.
Klein GJ; Gillberg JM; Tang A; Inbar S; Sharma A; Unterberg-Buchwald C; Dorian P; Moore H; Duru F; Rooney E; Becker D; Schaaf K; Benditt D;
J Cardiovasc Electrophysiol; 2006 Dec; 17(12):1310-9. PubMed ID: 17096661
[TBL] [Abstract][Full Text] [Related]
13. [Anti-tachycardia stimulation in supraventricular and ventricular tachycardia with and without cardioverter/defibrillator].
Klein H
Herz; 1991 Jun; 16(3):182-98. PubMed ID: 1889793
[TBL] [Abstract][Full Text] [Related]
14. Performance of a new single-chamber ICD algorithm: discrimination of supraventricular and ventricular tachycardia based on vector timing and correlation.
Corbisiero R; Lee MA; Nabert DR; Coman JA; Breiter DJ; Schwartz M; McKittrick E; Zhang Y
Europace; 2006 Dec; 8(12):1057-61. PubMed ID: 17105781
[TBL] [Abstract][Full Text] [Related]
15. Arrhythmia discrimination in implantable cardioverter defibrillators using support vector machines applied to a new representation of electrograms.
Milpied P; Dubois R; Roussel P; Henry C; Dreyfus G
IEEE Trans Biomed Eng; 2011 Jun; 58(6):1797-803. PubMed ID: 21342839
[TBL] [Abstract][Full Text] [Related]
16. Wavelet-based tachycardia discrimination in ICDs: Impact of posture and electrogram configuration.
Wolber T; Binggeli C; Holzmeister J; Brunckhorst C; Strobel U; Boes C; Moser R; Becker D; Duru F
Pacing Clin Electrophysiol; 2006 Nov; 29(11):1255-60. PubMed ID: 17100680
[TBL] [Abstract][Full Text] [Related]
17. Morphology discrimination in implantable cardioverter-defibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates.
Theuns DA; Rivero-Ayerza M; Goedhart DM; Miltenburg M; Jordaens LJ
Europace; 2008 Sep; 10(9):1060-6. PubMed ID: 18662939
[TBL] [Abstract][Full Text] [Related]
18. Morphological detection algorithms for the automatic implantable cardioverter/defibrillator (AICD).
Kaup HJ; Hexamer M; Werner J
Biomed Tech (Berl); 2004 Nov; 49(11):306-10. PubMed ID: 15624867
[TBL] [Abstract][Full Text] [Related]
19. Detection of atrial activity from high-voltage leads of implantable ventricular defibrillators using a cancellation technique.
Shkurovich S; Sahakian AV; Swiryn S
IEEE Trans Biomed Eng; 1998 Feb; 45(2):229-34. PubMed ID: 9473845
[TBL] [Abstract][Full Text] [Related]
20. Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device.
Francisco GM; Sharma S; Dougherty AH; Kantharia BK
Cardiol J; 2009; 16(5):473-6. PubMed ID: 19753529
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]