BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 16443454)

  • 1. Negative mode sheathless capillary electrophoresis electrospray ionization-mass spectrometry for metabolite analysis of prokaryotes.
    Edwards JL; Chisolm CN; Shackman JG; Kennedy RT
    J Chromatogr A; 2006 Feb; 1106(1-2):80-8. PubMed ID: 16443454
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of a sheathless CE-ESI-MS interface.
    Hirayama A; Abe H; Yamaguchi N; Tabata S; Tomita M; Soga T
    Electrophoresis; 2018 Jun; 39(11):1382-1389. PubMed ID: 29493797
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sheathless Capillary Electrophoresis-Mass Spectrometry for the Profiling of Charged Metabolites in Biological Samples.
    Ramautar R
    Methods Mol Biol; 2018; 1738():183-192. PubMed ID: 29654590
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins.
    Haselberg R; Ratnayake CK; de Jong GJ; Somsen GW
    J Chromatogr A; 2010 Nov; 1217(48):7605-11. PubMed ID: 20970804
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sheathless capillary electrophoresis electrospray ionization-mass spectrometry interface based on poly(dimethylsiloxane) membrane emitter and thin conducting liquid film.
    Wang CW; Her GR
    Electrophoresis; 2013 Sep; 34(17):2538-45. PubMed ID: 23775213
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-efficiency peptide analysis on monolithic multimode capillary columns: Pressure-assisted capillary electrochromatography/capillary electrophoresis coupled to UV and electrospray ionization-mass spectrometry.
    Ivanov AR; Horváth C; Karger BL
    Electrophoresis; 2003 Nov; 24(21):3663-73. PubMed ID: 14613191
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Enhancing the coverage of the urinary metabolome by sheathless capillary electrophoresis-mass spectrometry.
    Ramautar R; Busnel JM; Deelder AM; Mayboroda OA
    Anal Chem; 2012 Jan; 84(2):885-92. PubMed ID: 22148170
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sheathless electrospray ionization interfaces for capillary electrophoresis-mass spectrometric detection advantages and limitations.
    Issaq HJ; Janini GM; Chan KC; Veenstra TD
    J Chromatogr A; 2004 Oct; 1053(1-2):37-42. PubMed ID: 15543970
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A gold foil covered fused silica capillary tip as a sheathless interface for coupling capillary electrophoresis-mass spectrometry.
    Zhang H; Lou C; Li J; Kang J
    J Chromatogr A; 2020 Aug; 1624():461215. PubMed ID: 32540065
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sheathless Capillary Electrophoresis-Mass Spectrometry for Metabolic Profiling of Biological Samples.
    Zhang W; Gulersonmez MC; Hankemeier T; Ramautar R
    J Vis Exp; 2016 Oct; (116):. PubMed ID: 27768073
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Capillary electrophoresis in an extended nanospray tip-electrospray as an electrophoretic column.
    Tycova A; Foret F
    J Chromatogr A; 2015 Apr; 1388():274-9. PubMed ID: 25736305
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimization and evaluation of a sheathless capillary electrophoresis-electrospray ionization mass spectrometry platform for peptide analysis: comparison to liquid chromatography-electrospray ionization mass spectrometry.
    Faserl K; Sarg B; Kremser L; Lindner H
    Anal Chem; 2011 Oct; 83(19):7297-305. PubMed ID: 21848273
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design, optimisation, and evaluation of a sheath flow interface for automated capillary electrophoresis-electrospray-mass spectrometry.
    Liu CC; Alary JF; Vollmerhaus P; Kadkhodayan M
    Electrophoresis; 2005 Apr; 26(7-8):1366-75. PubMed ID: 15761922
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Coupling of non-aqueous electrokinetic chromatography using cationic cyclodextrins with electrospray ionization mass spectrometry.
    Mol R; de Jong GJ; Somsen GW
    Rapid Commun Mass Spectrom; 2008; 22(6):790-6. PubMed ID: 18275093
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip.
    Moini M
    Anal Chem; 2007 Jun; 79(11):4241-6. PubMed ID: 17447730
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Design and performance of a universal sheathless capillary electrophoresis to mass spectrometry interface using a split-flow technique.
    Moini M
    Anal Chem; 2001 Jul; 73(14):3497-501. PubMed ID: 11476254
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A colloidal graphite-coated emitter for sheathless capillary electrophoresis/nanoelectrospray ionization mass spectrometry.
    Zhu X; Thiam S; Valle BC; Warner IM
    Anal Chem; 2002 Oct; 74(20):5405-9. PubMed ID: 12403599
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine.
    Deng Y; Henion J; Li J; Thibault P; Wang C; Harrison DJ
    Anal Chem; 2001 Feb; 73(3):639-46. PubMed ID: 11217774
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of sheathless and sheath-flow electrospray interfaces for the capillary electrophoresis-electrospray ionization-mass spectrometry analysis of peptides.
    Sanz-Nebot V; Balaguer E; Benavente F; Barbosa J
    Electrophoresis; 2005 Apr; 26(7-8):1457-65. PubMed ID: 15776484
    [TBL] [Abstract][Full Text] [Related]  

  • 20. On-column sample enrichment for capillary electrophoresis sheathless electrospray ionization mass spectrometry: evaluation for peptide analysis and protein identification.
    Janini GM; Zhou M; Yu LR; Blonder J; Gignac M; Conrads TP; Issaq HJ; Veenstra TD
    Anal Chem; 2003 Nov; 75(21):5984-93. PubMed ID: 14588041
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.