  • 21. Venous ultrasound catheter-tip technique for evaluation of arterial hemodynamics.
    Nealeigh RC; Miller CW; McLeod FD
    J Appl Physiol; 1976 Dec; 41(6):946-52. PubMed ID: 1002651
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Towards the 2D velocity reconstruction in abdominal aorta from Color-Doppler Ultrasound.
    Antonuccio MN; Morales HG; This A; Capellini K; Avril S; Celi S; Rouet L
    Med Eng Phys; 2022 Sep; 107():103873. PubMed ID: 36068045
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Popliteal artery hemodynamics: MR imaging-US correlation.
    Dousset V; Wehrli FW; Louie A; Listerud J
    Radiology; 1991 May; 179(2):437-41. PubMed ID: 2014288
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Variability of splanchnic blood flow measurements using MR velocity mapping under fasting and post-prandial conditions--comparison with echo-Doppler.
    Lycklama à Nijeholt GJ; Burggraaf K; Wasser MN; Schultze Kool LJ; Schoemaker RC; Cohen AF; de Roos A
    J Hepatol; 1997 Feb; 26(2):298-304. PubMed ID: 9059950
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A vascular stent as an active component for locally enhanced magnetic resonance imaging: initial in vivo imaging results after catheter-guided placement in rabbits.
    Kivelitz D; Wagner S; Schnorr J; Wetzler R; Busch M; Melzer A; Taupitz M; Hamm B
    Invest Radiol; 2003 Mar; 38(3):147-52. PubMed ID: 12595794
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Measurement of the blood flow velocity in the pulmonary arteries using the magnetic resonance technique].
    Gamroth AH; Schad LR; Wacker CM; Gehling U; Knopp MV; Betsch B; Clorius JH; van Kaick G
    Radiologe; 1992 Apr; 32(4):182-4. PubMed ID: 1598416
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Measurement of flow in small vessels by magnetic resonance phase mapping techniques: an in vitro and in vivo study.
    Summers PE; Parsons SR; Taylor MG; Deverall PB; Padayachee TS
    MAGMA; 1997 Jun; 5(2):173-8. PubMed ID: 9268082
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Blood flow volume quantification of cerebral ischemia: comparison of three noninvasive imaging techniques of carotid and vertebral arteries.
    Ho SS; Chan YL; Yeung DK; Metreweli C
    AJR Am J Roentgenol; 2002 Mar; 178(3):551-6. PubMed ID: 11856672
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Direct and Doppler angle-independent measurement of blood flow velocity in small-diameter vessels using ultrasound microbubbles.
    Roy HS; Zuo G; Luo Z; Wu H; Krupka TM; Ran H; Li P; Sun Y; Wang Z; Zheng Y
    Clin Imaging; 2012; 36(5):577-83. PubMed ID: 22920365
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Validation of magnetic resonance phase-contrast flow measurements in the main pulmonary artery and aorta using perivascular ultrasound in a large animal model.
    Ley S; Unterhinninghofen R; Ley-Zaporozhan J; Schenk JP; Kauczor HU; Szabo G
    Invest Radiol; 2008 Jun; 43(6):421-6. PubMed ID: 18496047
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Quantitative transcutaneous arterial velocity measurements with Doppler flowmeters.
    Shoor PM; Fronek A; Bernstein EF
    Arch Surg; 1979 Aug; 114(8):922-8. PubMed ID: 157116
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison between retrospective gating and ECG triggering in magnetic resonance velocity mapping.
    Søndergaard L; Ståhlberg F; Thomsen C; Spraggins TA; Gymoese E; Malmgren L; Müller E; Henriksen O
    Magn Reson Imaging; 1993; 11(4):533-7. PubMed ID: 8316066
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Measurement of vessel wall strain using cine phase contrast MRI.
    Wedding KL; Draney MT; Herfkens RJ; Zarins CK; Taylor CA; Pelc NJ
    J Magn Reson Imaging; 2002 Apr; 15(4):418-28. PubMed ID: 11948831
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Serial echo-Doppler measurements of human fetal abdominal aortic blood flow.
    Eldridge MW; Berman W; Greene ER
    J Ultrasound Med; 1985 Sep; 4(9):453-8. PubMed ID: 3903195
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Blood flow velocity in the fetal abdominal aorta and in the umbilical artery in uncomplicated pregnancies.
    Künzel W; Jovanovic V; Grüssner S; Colling T
    Eur J Obstet Gynecol Reprod Biol; 1992 Oct; 47(1):31-40. PubMed ID: 1426509
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Non-invasive assessment of pulse wave velocity in mice by means of ultrasound images.
    Di Lascio N; Stea F; Kusmic C; Sicari R; Faita F
    Atherosclerosis; 2014 Nov; 237(1):31-7. PubMed ID: 25194332
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Peak velocity measurements in tortuous arteries with phase contrast magnetic resonance imaging: the effect of multidirectional velocity encoding.
    Schubert T; Bieri O; Pansini M; Stippich C; Santini F
    Invest Radiol; 2014 Apr; 49(4):189-94. PubMed ID: 24300842
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Quantification of blood velocity and flow rates in the uterine vessels using echo planar imaging at 0.5 Tesla.
    Issa B; Moore RJ; Bowtell RW; Baker PN; Johnson IR; Worthington BS; Gowland PA
    J Magn Reson Imaging; 2010 Apr; 31(4):921-7. PubMed ID: 20373437
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The Doppler signal: where does it come from and what does it mean?
    Nelson TR; Pretorius DH
    AJR Am J Roentgenol; 1988 Sep; 151(3):439-47. PubMed ID: 2970215
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Characterization of an abdominal aortic velocity waveform in patients with abdominal aortic aneurysm.
    Fraser KH; Meagher S; Blake JR; Easson WJ; Hoskins PR
    Ultrasound Med Biol; 2008 Jan; 34(1):73-80. PubMed ID: 17689855
    [TBL] [Abstract][Full Text] [Related]  