These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
99 related articles for article (PubMed ID: 1644547)
21. Towards the 2D velocity reconstruction in abdominal aorta from Color-Doppler Ultrasound. Antonuccio MN; Morales HG; This A; Capellini K; Avril S; Celi S; Rouet L Med Eng Phys; 2022 Sep; 107():103873. PubMed ID: 36068045 [TBL] [Abstract][Full Text] [Related]
23. Variability of splanchnic blood flow measurements using MR velocity mapping under fasting and post-prandial conditions--comparison with echo-Doppler. Lycklama à Nijeholt GJ; Burggraaf K; Wasser MN; Schultze Kool LJ; Schoemaker RC; Cohen AF; de Roos A J Hepatol; 1997 Feb; 26(2):298-304. PubMed ID: 9059950 [TBL] [Abstract][Full Text] [Related]
24. A vascular stent as an active component for locally enhanced magnetic resonance imaging: initial in vivo imaging results after catheter-guided placement in rabbits. Kivelitz D; Wagner S; Schnorr J; Wetzler R; Busch M; Melzer A; Taupitz M; Hamm B Invest Radiol; 2003 Mar; 38(3):147-52. PubMed ID: 12595794 [TBL] [Abstract][Full Text] [Related]
25. [Measurement of the blood flow velocity in the pulmonary arteries using the magnetic resonance technique]. Gamroth AH; Schad LR; Wacker CM; Gehling U; Knopp MV; Betsch B; Clorius JH; van Kaick G Radiologe; 1992 Apr; 32(4):182-4. PubMed ID: 1598416 [TBL] [Abstract][Full Text] [Related]
26. Measurement of flow in small vessels by magnetic resonance phase mapping techniques: an in vitro and in vivo study. Summers PE; Parsons SR; Taylor MG; Deverall PB; Padayachee TS MAGMA; 1997 Jun; 5(2):173-8. PubMed ID: 9268082 [TBL] [Abstract][Full Text] [Related]
27. Blood flow volume quantification of cerebral ischemia: comparison of three noninvasive imaging techniques of carotid and vertebral arteries. Ho SS; Chan YL; Yeung DK; Metreweli C AJR Am J Roentgenol; 2002 Mar; 178(3):551-6. PubMed ID: 11856672 [TBL] [Abstract][Full Text] [Related]
28. Direct and Doppler angle-independent measurement of blood flow velocity in small-diameter vessels using ultrasound microbubbles. Roy HS; Zuo G; Luo Z; Wu H; Krupka TM; Ran H; Li P; Sun Y; Wang Z; Zheng Y Clin Imaging; 2012; 36(5):577-83. PubMed ID: 22920365 [TBL] [Abstract][Full Text] [Related]
29. Validation of magnetic resonance phase-contrast flow measurements in the main pulmonary artery and aorta using perivascular ultrasound in a large animal model. Ley S; Unterhinninghofen R; Ley-Zaporozhan J; Schenk JP; Kauczor HU; Szabo G Invest Radiol; 2008 Jun; 43(6):421-6. PubMed ID: 18496047 [TBL] [Abstract][Full Text] [Related]
31. Comparison between retrospective gating and ECG triggering in magnetic resonance velocity mapping. Søndergaard L; Ståhlberg F; Thomsen C; Spraggins TA; Gymoese E; Malmgren L; Müller E; Henriksen O Magn Reson Imaging; 1993; 11(4):533-7. PubMed ID: 8316066 [TBL] [Abstract][Full Text] [Related]
32. Measurement of vessel wall strain using cine phase contrast MRI. Wedding KL; Draney MT; Herfkens RJ; Zarins CK; Taylor CA; Pelc NJ J Magn Reson Imaging; 2002 Apr; 15(4):418-28. PubMed ID: 11948831 [TBL] [Abstract][Full Text] [Related]
33. Serial echo-Doppler measurements of human fetal abdominal aortic blood flow. Eldridge MW; Berman W; Greene ER J Ultrasound Med; 1985 Sep; 4(9):453-8. PubMed ID: 3903195 [TBL] [Abstract][Full Text] [Related]
34. Blood flow velocity in the fetal abdominal aorta and in the umbilical artery in uncomplicated pregnancies. Künzel W; Jovanovic V; Grüssner S; Colling T Eur J Obstet Gynecol Reprod Biol; 1992 Oct; 47(1):31-40. PubMed ID: 1426509 [TBL] [Abstract][Full Text] [Related]
35. Non-invasive assessment of pulse wave velocity in mice by means of ultrasound images. Di Lascio N; Stea F; Kusmic C; Sicari R; Faita F Atherosclerosis; 2014 Nov; 237(1):31-7. PubMed ID: 25194332 [TBL] [Abstract][Full Text] [Related]
36. Peak velocity measurements in tortuous arteries with phase contrast magnetic resonance imaging: the effect of multidirectional velocity encoding. Schubert T; Bieri O; Pansini M; Stippich C; Santini F Invest Radiol; 2014 Apr; 49(4):189-94. PubMed ID: 24300842 [TBL] [Abstract][Full Text] [Related]
37. Quantification of blood velocity and flow rates in the uterine vessels using echo planar imaging at 0.5 Tesla. Issa B; Moore RJ; Bowtell RW; Baker PN; Johnson IR; Worthington BS; Gowland PA J Magn Reson Imaging; 2010 Apr; 31(4):921-7. PubMed ID: 20373437 [TBL] [Abstract][Full Text] [Related]
38. The Doppler signal: where does it come from and what does it mean? Nelson TR; Pretorius DH AJR Am J Roentgenol; 1988 Sep; 151(3):439-47. PubMed ID: 2970215 [TBL] [Abstract][Full Text] [Related]
39. Characterization of an abdominal aortic velocity waveform in patients with abdominal aortic aneurysm. Fraser KH; Meagher S; Blake JR; Easson WJ; Hoskins PR Ultrasound Med Biol; 2008 Jan; 34(1):73-80. PubMed ID: 17689855 [TBL] [Abstract][Full Text] [Related]
40. Limitations of a pulsed Doppler velocimeter for blood flow measurement in small vessels. Quail AW; Cottee DB; White SW J Appl Physiol (1985); 1993 Dec; 75(6):2745-54. PubMed ID: 8125899 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]