These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Confusing restart procedure on the Puritan-Bennett Achieva ventilator could delay ventilation. Health Devices; 2004 Sep; 33(9):337. PubMed ID: 15532861 [No Abstract] [Full Text] [Related]
4. [JIS draft proposal for lung ventilators for medical use]. Sato T Masui; 1985 Jun; 34(6):873-85. PubMed ID: 3861879 [No Abstract] [Full Text] [Related]
5. [Non-invasive continuous evaluation of work of breathing during pressure support ventilation]. Iotti G; Braschi A; Brunner JX; Raimondi F; Rodi G; Olivei M; Palo A Minerva Anestesiol; 1991 Oct; 57(10):863. PubMed ID: 1961524 [No Abstract] [Full Text] [Related]
6. Imposed work of breathing during ventilator failure. Austin PN; Campbell RS; Johannigman JA; Branson RD Respir Care; 2002 Jun; 47(6):667-74. PubMed ID: 12036436 [TBL] [Abstract][Full Text] [Related]
12. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation. DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147 [TBL] [Abstract][Full Text] [Related]
13. Variations in tidal volume with portable transport ventilators. McGough EK; Banner MJ; Melker RJ Respir Care; 1992 Mar; 37(3):233-9. PubMed ID: 10145629 [TBL] [Abstract][Full Text] [Related]
14. Hazard report. Unfamiliarity with differences in the way ventilators set pressure-control values may lead to lung injuries. Health Devices; 2010 Jun; 39(6):206-7. PubMed ID: 21309286 [TBL] [Abstract][Full Text] [Related]
15. Breathing circuits for critical care ventilators. Health Devices; 1994 Apr; 23(4):104-30. PubMed ID: 8034513 [No Abstract] [Full Text] [Related]
16. Noninvasive positive pressure ventilation. Equipment and techniques. Drinkwine J; Kacmarek RM Respir Care Clin N Am; 1996 Jun; 2(2):183-94. PubMed ID: 9390878 [TBL] [Abstract][Full Text] [Related]
17. Enhanced capabilities of current ICU ventilators: do they really benefit patients? Branson RD Respir Care; 1991 May; 36(5):362-76. PubMed ID: 10145436 [TBL] [Abstract][Full Text] [Related]
18. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators]. Nishimura M; Imanaka H; Taenaka N; Yoshiya I; Takezawa J Masui; 1989 Aug; 38(8):1017-29. PubMed ID: 2681861 [TBL] [Abstract][Full Text] [Related]
19. Barotrauma from CPAP systems lacking pressure relief. Health Devices; 1996 Sep; 25(9):343-5. PubMed ID: 8878727 [No Abstract] [Full Text] [Related]