4. Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy. John R; Kamdar F; Liao K; Colvin-Adams M; Boyle A; Joyce L Ann Thorac Surg; 2008 Oct; 86(4):1227-34; discussion 1234-5. PubMed ID: 18805167 [TBL] [Abstract][Full Text] [Related]
5. Left ventricular assist device placement in a patient with end-stage heart failure and human immunodeficiency virus. Fieno DS; Czer LS; Schwarz ER; Simsir S Interact Cardiovasc Thorac Surg; 2009 Nov; 9(5):919-20. PubMed ID: 19706718 [TBL] [Abstract][Full Text] [Related]
6. Outcomes of left ventricular assist device implantation as destination therapy in the post-REMATCH era: implications for patient selection. Lietz K; Long JW; Kfoury AG; Slaughter MS; Silver MA; Milano CA; Rogers JG; Naka Y; Mancini D; Miller LW Circulation; 2007 Jul; 116(5):497-505. PubMed ID: 17638928 [TBL] [Abstract][Full Text] [Related]
7. First clinical implant of the VentrAssist left ventricular assist system as destination therapy for end-stage heart failure. Esmore DS; Kaye D; Salamonsen R; Buckland M; Rowland M; Negri J; Rowley Y; Woodard J; Begg JR; Ayre P; Rosenfeldt FL J Heart Lung Transplant; 2005 Aug; 24(8):1150-4. PubMed ID: 16102463 [TBL] [Abstract][Full Text] [Related]
8. Placement of a continuous-flow ventricular assist device in the failing ventricle of an adult patient with complex cyanotic congenital heart disease. Morris CD; Gregoric ID; Cooley DA; Cohn WE; Loyalka P; Frazier OH Heart Surg Forum; 2008; 11(3):E143-4. PubMed ID: 18583283 [TBL] [Abstract][Full Text] [Related]
9. Assessment of recurrent heart failure associated with left ventricular assist device dysfunction. Jaski BE; Miller DA; Hoagland PM; Gordon JB; Chillcott SR; Stahovich MJ; Adamson RM; Baradarian S; Dembitsky WP J Heart Lung Transplant; 2005 Dec; 24(12):2060-7. PubMed ID: 16364850 [TBL] [Abstract][Full Text] [Related]
10. Prognostic value of left ventricular apical tissue removed for HeartMate II left ventricular assist device placement. Soderlund KA; Chivukula RR; Russell SD; Conte JV; Mudd JO; Halushka MK Cardiovasc Pathol; 2009; 18(4):217-22. PubMed ID: 18706833 [TBL] [Abstract][Full Text] [Related]
11. Improving outcomes with long-term "destination" therapy using left ventricular assist devices. Long JW; Healy AH; Rasmusson BY; Cowley CG; Nelson KE; Kfoury AG; Clayson SE; Reid BB; Moore SA; Blank DU; Renlund DG J Thorac Cardiovasc Surg; 2008 Jun; 135(6):1353-60; discussion 1360-1. PubMed ID: 18544385 [TBL] [Abstract][Full Text] [Related]
12. Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices. Patel ND; Weiss ES; Schaffer J; Ullrich SL; Rivard DC; Shah AS; Russell SD; Conte JV Ann Thorac Surg; 2008 Sep; 86(3):832-40; discussion 832-40. PubMed ID: 18721570 [TBL] [Abstract][Full Text] [Related]
13. Age and outcome after continuous-flow left ventricular assist device implantation as bridge to transplantation. Sandner SE; Zimpfer D; Zrunek P; Rajek A; Schima H; Dunkler D; Zuckermann AO; Wieselthaler GM J Heart Lung Transplant; 2009 Apr; 28(4):367-72. PubMed ID: 19332264 [TBL] [Abstract][Full Text] [Related]
14. Destination therapy: does progress depend on left ventricular assist device development? von Bayern MP; Cadeiras M; Deng MC Heart Fail Clin; 2007 Jul; 3(3):349-67. PubMed ID: 17723941 [TBL] [Abstract][Full Text] [Related]
15. Implantable left ventricular assist devices: new hope for patients with end-stage heart failure. Milano CA; Lodge AJ; Blue LJ; Smith PK; Felker GM; Hernandez AF; Rosenberg PB; Rogers JG N C Med J; 2006; 67(2):110-5. PubMed ID: 16752713 [TBL] [Abstract][Full Text] [Related]
16. Minimally invasive, off-pump explant of a continuous-flow left ventricular assist device. Cheung A; Bashir J; Kaan A; Kealy J; Moss R; Shayan H J Heart Lung Transplant; 2010 Jul; 29(7):808-10. PubMed ID: 20363154 [TBL] [Abstract][Full Text] [Related]
17. Biventricular assist device implantation as bridge to heart transplantation concomitant with open repair of infrarenal aortic aneurysm. Kindo M; Carranza D; Eisenmann B; Mazzucotelli JP Interact Cardiovasc Thorac Surg; 2008 Aug; 7(4):738-9. PubMed ID: 18469012 [TBL] [Abstract][Full Text] [Related]
18. "Unpredictable" late rupture of an abdominal aortic aneurysm after bifurcated Ancure endograft repair. Rosen NA; Cayne NS; Macari M; Jacobowitz GR Vasc Endovascular Surg; 2008; 42(1):69-73. PubMed ID: 18238872 [TBL] [Abstract][Full Text] [Related]
19. Analysis of platelet function during left ventricular support with the Incor and Excor system. Etz C; Welp H; Rothenburger M; Tjan TD; Wenzelburger F; Schmidt C; Scheld HH; Schmid C Heart Surg Forum; 2004; 7(5):E423-7. PubMed ID: 15799917 [TBL] [Abstract][Full Text] [Related]