These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 16449210)

  • 21. Incidence of Undetectable, Measurable, and Increased Cardiac Troponin I Concentrations Above the 99th Percentile Using a High-Sensitivity vs a Contemporary Assay in Patients Presenting to the Emergency Department.
    Love SA; Sandoval Y; Smith SW; Nicholson J; Cao J; Ler R; Schulz K; Apple FS
    Clin Chem; 2016 Aug; 62(8):1115-9. PubMed ID: 27324737
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Analytical evaluation of the new Beckman Coulter Access high sensitivity cardiac troponin I immunoassay.
    Lippi G; Ferrari A; Gandini G; Gelati M; Lo Cascio C; Salvagno GL
    Clin Chem Lab Med; 2017 Nov; 56(1):157-161. PubMed ID: 28704179
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Analytic and clinical utility of a next-generation, highly sensitive cardiac troponin I assay for early detection of myocardial injury.
    Kavsak PA; MacRae AR; Yerna MJ; Jaffe AS
    Clin Chem; 2009 Mar; 55(3):573-7. PubMed ID: 19168557
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Determination of 19 cardiac troponin I and T assay 99th percentile values from a common presumably healthy population.
    Apple FS; Ler R; Murakami MM
    Clin Chem; 2012 Nov; 58(11):1574-81. PubMed ID: 22983113
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Performance of the Advia Centaur second-generation troponin assay TnI-Ultra compared with the first-generation cTnI assay.
    van de Kerkhof D; Peters B; Scharnhorst V
    Ann Clin Biochem; 2008 May; 45(Pt 3):316-7. PubMed ID: 18482922
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparing analytical outliers and the percent of emergency department patients with results above the 99th percentile upper reference limit for 2 conventional and one high sensitivity troponin assay.
    Karon BS; Wockenfus AM; Hartung KJ; Scott RJ; Carter SD; Jaffe AS
    Clin Biochem; 2018 Mar; 53():104-109. PubMed ID: 29305092
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Pilot study on harmonization of cardiac troponin I immunoassays using patients and quality control plasma samples. On behalf of the Italian Section of the European Ligand Assay Society (ELAS) and of the Study Group on Cardiovascular Biomarkers of the Società Italiana di Biochimica Clinica (SIBioC).
    Clerico A; Ripoli A; Masotti S; Prontera C; Storti S; Fortunato A; Buzzi P; Casagranda I; Franzini M; Ndreu R; Zucchelli GC; Zaninotto M; Plebani M
    Clin Chim Acta; 2016 May; 456():42-48. PubMed ID: 26923393
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Analytical evaluation of a new point of care system for measuring cardiac Troponin I.
    Kemper DW; Semjonow V; de Theije F; Keizer D; van Lippen L; Mair J; Wille B; Christ M; Geier F; Hausfater P; Pariente D; Scharnhorst V; Curvers J; Nieuwenhuis J
    Clin Biochem; 2017 Mar; 50(4-5):174-180. PubMed ID: 27847339
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluation of innotrac aio! Second-generation cardiac troponin I assay: the main characteristics for routine clinical use.
    Hedberg P; Valkama J; Suvanto E; Pikkujämsä S; Ylitalo K; Alasaarela E; Puukka M
    J Autom Methods Manag Chem; 2006; 2006():39325. PubMed ID: 17671616
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Analytical comparison of three different versions of a high-sensitivity cardiac troponin I assay over 10years.
    Kavsak PA; Worster A; Hill SA; MacRae AR; Jaffe AS
    Clin Chim Acta; 2017 Dec; 475():51-55. PubMed ID: 29017768
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of analytical performance of the Pathfast cardiac troponin I.
    Di Serio F; Caputo M; Zaninotto M; Ottomano C; Plebani M
    Clin Chem Lab Med; 2009; 47(7):829-33. PubMed ID: 19453290
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Elevation of cardiac troponins measured after recreational resistance training.
    Savukoski T; Mehtälä L; Lindahl B; Venge P; Pettersson K
    Clin Biochem; 2015 Aug; 48(12):803-6. PubMed ID: 26116764
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The comparative analytical performance of four troponin I assays at low concentration.
    Koerbin G; Tate JR; Potter JM; Hickman PE
    Ann Clin Biochem; 2005 Jan; 42(Pt 1):19-23. PubMed ID: 15802028
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Impact on Patient Management and Outcome of Switching between 2 Contemporary Sensitive Cardiac Troponin Assays.
    Wilen CB; Szymanski JJ; Hung S; Rajan A; Lavigne PM; Char DM; Geltman EM; Scott MG
    Clin Chem; 2015 Jun; 61(6):870-6. PubMed ID: 25886769
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Analytical characterization of the Siemens Dimension EXL high-sensitivity cardiac troponin I assay.
    Kavsak PA; MacCuish J; Boreyko J; Roy C; Lamers S; Clark L
    Clin Biochem; 2019 Jul; 69():52-56. PubMed ID: 31063741
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Cardiac troponin assay classification by both clinical and analytical performance characteristics: a study on outcome prediction.
    Venge P; Lindahl B
    Clin Chem; 2013 Jun; 59(6):976-81. PubMed ID: 23481696
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Determination of high-sensitivity cardiac troponin I 99th percentile upper reference limits in a healthy Korean population.
    Ji M; Moon HW; Hur M; Yun YM
    Clin Biochem; 2016 Jul; 49(10-11):756-61. PubMed ID: 27067595
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Sensitive troponin assays and N-terminal pro-B-type natriuretic peptide in acute coronary syndrome: prediction of significant coronary lesions and long-term prognosis.
    Gravning J; Smedsrud MK; Omland T; Eek C; Skulstad H; Aaberge L; Bendz B; Kjekshus J; Mørkrid L; Edvardsen T
    Am Heart J; 2013 May; 165(5):716-24. PubMed ID: 23622908
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of cardiac troponin I immunoassays variably affected by circulating autoantibodies.
    Eriksson S; Ilva T; Becker C; Lund J; Porela P; Pulkki K; Voipio-Pulkki LM; Pettersson K
    Clin Chem; 2005 May; 51(5):848-55. PubMed ID: 15718488
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Performance of a revised cardiac troponin method that minimizes interferences from heterophilic antibodies.
    Kim WJ; Laterza OF; Hock KG; Pierson-Perry JF; Kaminski DM; Mesguich M; Braconnier F; Zimmermann R; Zaninotto M; Plebani M; Hanna A; Cembrowski GS; Scott MG
    Clin Chem; 2002 Jul; 48(7):1028-34. PubMed ID: 12089171
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.