BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

238 related articles for article (PubMed ID: 16463491)

  • 1. Design, fabrication and characterization of a capacitive micromachined ultrasonic probe for medical imaging.
    Caliano G; Carotenuto R; Cianci E; Foglietti V; Caronti A; Iula A; Pappalardo M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2259-69. PubMed ID: 16463491
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Capacitive micromachined ultrasonic transducers: fabrication technology.
    Ergun AS; Huang Y; Zhuang X; Oralkan O; Yaralioglu GG; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2242-58. PubMed ID: 16463490
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Capacitive micromachined ultrasonic transducers (CMUTs) with isolation posts.
    Huang Y; Zhuang X; Haeggstrom EO; Ergun AS; Cheng CH; Khuri-Yakub BT
    Ultrasonics; 2008 Mar; 48(1):74-81. PubMed ID: 18207212
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dynamic analysis of capacitive micromachined ultrasonic transducers.
    Bayram B; Yaralioglu GG; Kupnik M; Ergun AS; Oralkan O; Nikoozadeh A; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2270-5. PubMed ID: 16463492
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays.
    Ciçek I; Bozkurt A; Karaman M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2235-41. PubMed ID: 16463489
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimization of the gain-bandwidth product of capacitive micromachined ultrasonic transducers.
    Olcum S; Senlik MN; Atalar A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2211-9. PubMed ID: 16463487
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of micromachined ultrasonic transducers using light diffraction tomography.
    Almqvist M; Törndahl M; Nilsson M; Lilliehorn T
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2298-302. PubMed ID: 16463495
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Forward-viewing CMUT arrays for medical imaging.
    Demirci U; Ergun AS; Oralkan O; Karaman M; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 2004 Jul; 51(7):887-95. PubMed ID: 15301009
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Parametric linear modeling of circular cMUT membranes in vacuum.
    Köymen H; Senlik MN; Atalar A; Olcum S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Jun; 54(6):1229-39. PubMed ID: 17571821
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging?
    Oralkan O; Ergun AS; Johnson JA; Karaman M; Demirci U; Kaviani K; Lee TH; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 2002 Nov; 49(11):1596-610. PubMed ID: 12484483
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Exploitation of capacitive micromachined transducers for nonlinear ultrasound imaging.
    Novell A; Legros M; Felix N; Bouakaz A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Dec; 56(12):2733-43. PubMed ID: 20040410
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A 32 x 32 capacitive micromachined ultrasonic transducer array manufactured in standard CMOS.
    Lemmerhirt DF; Cheng X; White R; Rich CA; Zhang M; Fowlkes JB; Kripfgans OD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Jul; 59(7):1521-36. PubMed ID: 22828847
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Acoustic coupling in capacitive microfabricated ultrasonic transducers: modeling and experiments.
    Caronti A; Savoia A; Caliano G; Pappalardo M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2220-34. PubMed ID: 16463488
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A finite difference model for cMUT devices.
    Certon D; Teston F; Patat F
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2199-210. PubMed ID: 16463486
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A CMUT probe for medical ultrasonography: from microfabrication to system integration.
    Savoia AS; Calianov G; Pappalardo M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Jun; 59(6):1127-38. PubMed ID: 22711408
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Piezoelectric micromachined ultrasonic transducers based on PZT thin films.
    Muralt P; Ledermann N; Baborowski J; Barzegar A; Gentil S; Belgacem B; Petitgrand S; Bosseboeuf A; Setter N
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2276-88. PubMed ID: 16463493
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Acoustic backing in 3-D integration of CMUT with front-end electronics.
    Berg S; Rønnekleiv A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Jul; 59(7):1537-49. PubMed ID: 22828848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Capacitive micromachined ultrasonic transducers using commercial multi-user MUMPs process: capability and limitations.
    Liu J; Oakley C; Shandas R
    Ultrasonics; 2009 Dec; 49(8):765-73. PubMed ID: 19640557
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Finite-element analysis of capacitive micromachined ultrasonic transducers.
    Yaralioglu GG; Ergun AS; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Dec; 52(12):2185-98. PubMed ID: 16463485
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optical micromachined ultrasound transducers (OMUT)--a new approach for high-frequency transducers.
    Tadayon MA; Ashkenazi S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Sep; 60(9):2021-30. PubMed ID: 24658733
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.