These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 16463823)

  • 1. Estimated cerebral respiratory quotient and arteriovenous differences of CO2 in the ultra early detection of global ischemia in severe head injury.
    Chieregato A; Marchi M; Compagnone C; Albarello V; Fainardi E; Tagliaferri F; Targa L
    Acta Neurochir Suppl; 2005; 95():67-71. PubMed ID: 16463823
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection of early ischemia in severe head injury by means of arteriovenous lactate differences and jugular bulb oxygen saturation. Relationship with CPP, severity indexes and outcome. Preliminary analysis.
    Chieregato A; Marchi M; Zoppellari R; Fabbri E; Cianchi G; Forini E; Targa L
    Acta Neurochir Suppl; 2002; 81():289-93. PubMed ID: 12168328
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Re-defining the ischemic threshold for jugular venous oxygen saturation--a microdialysis study in patients with severe head injury.
    Chan MT; Ng SC; Lam JM; Poon WS; Gin T
    Acta Neurochir Suppl; 2005; 95():63-6. PubMed ID: 16463822
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cerebral arterio-venous pCO2 difference, estimated respiratory quotient, and early posttraumatic outcome: comparison with arterio-venous lactate and oxygen differences.
    Chieregato A; Marchi M; Fainardi E; Targa L
    J Neurosurg Anesthesiol; 2007 Oct; 19(4):222-8. PubMed ID: 17893572
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cerebral arteriovenous PCO2 difference and early global cerebral ischemia in a patient with acute severe head injury.
    Chieregato A; Zoppellari R; Targa L
    J Neurosurg Anesthesiol; 1997 Jul; 9(3):256-62. PubMed ID: 9239589
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monitoring of cerebral oxygen metabolism in the jugular bulb: reliability of unilateral measurements in severe head injury.
    Metz C; Holzschuh M; Bein T; Woertgen C; Rothoerl R; Kallenbach B; Taeger K; Brawanski A
    J Cereb Blood Flow Metab; 1998 Mar; 18(3):332-43. PubMed ID: 9498850
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cerebral hemodynamic changes during sustained hypocapnia in severe head injury: can hyperventilation cause cerebral ischemia?
    Ausina A; Báguena M; Nadal M; Manrique S; Ferrer A; Sahuquillo J; Garnacho A
    Acta Neurochir Suppl; 1998; 71():1-4. PubMed ID: 9779127
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Continuous fiberoptic monitoring of oxygen saturation in cerebral veins in severe craniocerebral trauma--experiences and results].
    Murr R; Schürer L; Polasek J
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1996 Feb; 31(1):29-36. PubMed ID: 8868530
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The accuracy of jugular bulb venous monitoring in detecting cerebral ischemia in awake patients undergoing carotid endarterectomy.
    Moritz S; Kasprzak P; Woertgen C; Taeger K; Metz C
    J Neurosurg Anesthesiol; 2008 Jan; 20(1):8-14. PubMed ID: 18157019
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analysis of abnormal jugular bulb oxygen saturation data in patients with severe head injury.
    de Deyne C; Vandekerckhove T; Decruyenaere J; Colardyn F
    Acta Neurochir (Wien); 1996; 138(12):1409-15. PubMed ID: 9030347
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validity and reliability of the SjO2 catheter in neurologically impaired patients: a critical review of the literature.
    Clay HD
    J Neurosci Nurs; 2000 Aug; 32(4):194-203. PubMed ID: 10994532
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Continuous monitoring of jugular bulb oxygen saturation as a measure of the shunt flow of cerebral arteriovenous malformations.
    Katayama Y; Tsubokawa T; Hirayama T; Himi K
    J Neurosurg; 1994 May; 80(5):826-33. PubMed ID: 8169621
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correlation of jugular venous oxygen saturation to spontaneous fluctuations of cerebral perfusion pressure in patients with severe head injury.
    Murr R; Schürer L
    Neurol Res; 1995 Oct; 17(5):329-33. PubMed ID: 8584122
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Arterio-jugular difference of oxygen content and outcome after head injury.
    Stocchetti N; Canavesi K; Magnoni S; Valeriani V; Conte V; Rossi S; Longhi L; Zanier ER; Colombo A
    Anesth Analg; 2004 Jul; 99(1):230-234. PubMed ID: 15281535
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous monitoring of jugular venous oxygen saturation in head-injured patients.
    Sheinberg M; Kanter MJ; Robertson CS; Contant CF; Narayan RK; Grossman RG
    J Neurosurg; 1992 Feb; 76(2):212-7. PubMed ID: 1472169
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intracerebral steal phenomenon associated with global hyperemia in moyamoya disease during revascularization surgery.
    Oshima H; Katayama Y; Hirayama T
    J Neurosurg; 2000 Jun; 92(6):949-54. PubMed ID: 10839254
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Continuous monitoring of cerebrospinal fluid acid-base balance and oxygen metabolism in patients with severe head injury: pathophysiology and treatments for cerebral acidosis and ischemia.
    Shiogai T; Nara I; Saruta K; Hara M; Saito I
    Acta Neurochir Suppl; 1999; 75():49-55. PubMed ID: 10635377
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment of jugular blood oxygen and lactate indices for detection of cerebral ischemia and prognosis.
    Artru F; Dailler F; Burel E; Bodonian C; Grousson S; Convert J; Renaud B; Perret-Liaudet A
    J Neurosurg Anesthesiol; 2004 Jul; 16(3):226-31. PubMed ID: 15211160
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Prognostic estimation of cerebral arterio-venous difference of oxygen content (c-AVDO2) on severe head injury patients].
    Takeuchi T
    No Shinkei Geka; 1989 Dec; 17(12):1119-24. PubMed ID: 2615894
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Cerebral oximetry by infrared spectroscopy in comparison with continuous measurement of oxygen saturation of the jugular vein bulb in interventions of the internal carotid artery].
    Schindler E; Zickmann B; Müller M; Boldt J; Kroll J; Hempelmann G
    Vasa; 1995; 24(2):168-75. PubMed ID: 7793150
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.