139 related articles for article (PubMed ID: 16463825)
1. Brain tissue oxygen (PtiO2): a clinical comparison of two monitoring devices.
Jaeger M; Soehle M; Meixensberger J
Acta Neurochir Suppl; 2005; 95():79-81. PubMed ID: 16463825
[TBL] [Abstract][Full Text] [Related]
2. In vitro comparison of two generations of Licox and Neurotrend catheters.
Haitsma I; Rosenthal G; Morabito D; Rollins M; Maas AI; Manley GT
Acta Neurochir Suppl; 2008; 102():197-202. PubMed ID: 19388316
[TBL] [Abstract][Full Text] [Related]
3. Cerebral oxygenation in contusioned vs. nonlesioned brain tissue: monitoring of PtiO2 with Licox and Paratrend.
Sarrafzadeh AS; Kiening KL; Bardt TF; Schneider GH; Unterberg AW; Lanksch WR
Acta Neurochir Suppl; 1998; 71():186-9. PubMed ID: 9779180
[TBL] [Abstract][Full Text] [Related]
4. Brain oxygen monitoring: in-vitro accuracy, long-term drift and response-time of Licox- and Neurotrend sensors.
Hoelper BM; Alessandri B; Heimann A; Behr R; Kempski O
Acta Neurochir (Wien); 2005 Jul; 147(7):767-74; discussion 774. PubMed ID: 15889319
[TBL] [Abstract][Full Text] [Related]
5. Clinical evaluation of a new multiparameter neuromonitoring device: measurement of brain tissue oxygen, brain temperature, and intracranial pressure.
Huschak G; Hoell T; Hohaus C; Kern C; Minkus Y; Meisel HJ
J Neurosurg Anesthesiol; 2009 Apr; 21(2):155-60. PubMed ID: 19295395
[TBL] [Abstract][Full Text] [Related]
6. Correlation of continuously monitored regional cerebral blood flow and brain tissue oxygen.
Jaeger M; Soehle M; Schuhmann MU; Winkler D; Meixensberger J
Acta Neurochir (Wien); 2005 Jan; 147(1):51-6; discussion 56. PubMed ID: 15565486
[TBL] [Abstract][Full Text] [Related]
7. Reliability of the NeuroTrend sensor system under hyperbaric conditions.
Henze D; Bomplitz M; Radke J; Clausen T
J Neurosci Methods; 2004 Jan; 132(1):45-56. PubMed ID: 14687674
[TBL] [Abstract][Full Text] [Related]
8. Brain tissue oxygen monitoring: a study of in vitro accuracy and stability of Neurovent-PTO and Licox sensors.
Purins K; Enblad P; Sandhagen B; Lewén A
Acta Neurochir (Wien); 2010 Apr; 152(4):681-8. PubMed ID: 19826757
[TBL] [Abstract][Full Text] [Related]
9. Monitoring brain tissue oxygen tension in brain-injured patients reveals hypoxic episodes in normal-appearing and in peri-focal tissue.
Longhi L; Pagan F; Valeriani V; Magnoni S; Zanier ER; Conte V; Branca V; Stocchetti N
Intensive Care Med; 2007 Dec; 33(12):2136-42. PubMed ID: 17846748
[TBL] [Abstract][Full Text] [Related]
10. Clinical experience with 118 brain tissue oxygen partial pressure catheter probes.
Dings J; Meixensberger J; Jäger A; Roosen K
Neurosurgery; 1998 Nov; 43(5):1082-95. PubMed ID: 9802852
[TBL] [Abstract][Full Text] [Related]
11. [Applications of the determination of brain tissue oxygen pressure (PtiO2)].
Gelabert-González M; Villa JM
Rev Neurol; 2003 Apr 16-30; 36(8):744-9. PubMed ID: 12717654
[TBL] [Abstract][Full Text] [Related]
12. Influence of hyperventilation on brain tissue-PO2, PCO2, and pH in patients with intracranial hypertension.
Schneider GH; Sarrafzadeh AS; Kiening KL; Bardt TF; Unterberg AW; Lanksch WR
Acta Neurochir Suppl; 1998; 71():62-5. PubMed ID: 9779146
[TBL] [Abstract][Full Text] [Related]
13. The new Licox combined brain tissue oxygen and brain temperature monitor: assessment of in vitro accuracy and clinical experience in severe traumatic brain injury.
Stewart C; Haitsma I; Zador Z; Hemphill JC; Morabito D; Manley G; Rosenthal G
Neurosurgery; 2008 Dec; 63(6):1159-64; discussion 1164-5. PubMed ID: 19057329
[TBL] [Abstract][Full Text] [Related]
14. Effects of hyperoxia on brain tissue oxygen tension in cerebral focal lesions.
Longhi L; Valeriani V; Rossi S; De Marchi M; Egidi M; Stocchetti N
Acta Neurochir Suppl; 2002; 81():315-7. PubMed ID: 12168335
[TBL] [Abstract][Full Text] [Related]
15. Online assessment of brain tissue oxygen autoregulation in traumatic brain injury and subarachnoid hemorrhage.
Soehle M; Jaeger M; Meixensberger J
Neurol Res; 2003 Jun; 25(4):411-7. PubMed ID: 12870270
[TBL] [Abstract][Full Text] [Related]
16. Room Air Readings of Brain Tissue Oxygenation Probes.
Wolf S; Schürer L; Engel DC
Acta Neurochir Suppl; 2018; 126():197-199. PubMed ID: 29492560
[TBL] [Abstract][Full Text] [Related]
17. Comparing brain tissue oxygen measurements and derived autoregulation parameters from different probes (Licox vs. Raumedic).
Dengl M; Jaeger M; Renner C; Meixensberger J
Acta Neurochir Suppl; 2012; 114():165-8. PubMed ID: 22327685
[TBL] [Abstract][Full Text] [Related]
18. Brain tissue pO2 in relation to cerebral perfusion pressure, TCD findings and TCD-CO2-reactivity after severe head injury.
Dings J; Meixensberger J; Amschler J; Hamelbeck B; Roosen K
Acta Neurochir (Wien); 1996; 138(4):425-34. PubMed ID: 8738393
[TBL] [Abstract][Full Text] [Related]
19. Brain tissue oxygen pressure monitoring in awake patients during functional neurosurgery: the assessment of normal values.
Pennings FA; Schuurman PR; van den Munckhof P; Bouma GJ
J Neurotrauma; 2008 Oct; 25(10):1173-7. PubMed ID: 18847378
[TBL] [Abstract][Full Text] [Related]
20. Reviewing the reliability, effectiveness and applications of Licox in traumatic brain injury.
Keddie S; Rohman L
Nurs Crit Care; 2012; 17(4):204-12. PubMed ID: 22698163
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]