These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Japanese standard reference material for JDS Lot 2 haemoglobin A1c. I: Comparison of Japan Diabetes Society-assigned values to those obtained by the Japanese and USA domestic standardization programmes and by the International Federation of Clinical Chemistry reference laboratories. Tominaga M; Makino H; Yoshino G; Kuwa K; Takei I; Aono Y; Hoshino T; Umemoto M; Shimatsu A; Sanke T; Kuwashima M; Taminato T; Ono J Ann Clin Biochem; 2005 Jan; 42(Pt 1):41-6. PubMed ID: 15802031 [TBL] [Abstract][Full Text] [Related]
4. Implementation of haemoglobin A1c results traceable to the IFCC reference system: the way forward. Panteghini M; John WG; Clin Chem Lab Med; 2007; 45(8):942-4. PubMed ID: 17867982 [No Abstract] [Full Text] [Related]
5. Standardization of the hemoglobin A1c reporting: transferring global consensus to the local community--special report. Lovrencić MV; Metelko Z Biochem Med (Zagreb); 2011; 21(1):53-4. PubMed ID: 22141207 [No Abstract] [Full Text] [Related]
6. Diabetes mellitus: the long way of standardization of HbA(1c) to the level of highest metrological order. Kaiser P; Reinauer H Ger Med Sci; 2011; 9():Doc28. PubMed ID: 22135621 [TBL] [Abstract][Full Text] [Related]
7. Haemoglobin A1c: analysis and standardisation. John WG Clin Chem Lab Med; 2003 Sep; 41(9):1199-212. PubMed ID: 14598870 [TBL] [Abstract][Full Text] [Related]
8. Japanese standard reference material JDS Lot 2 for haemoglobin A1c. II: Present state of standardization of haemoglobin A1c in Japan using the new reference material in routine clinical assays. Tominaga M; Makino H; Yoshino G; Kuwa K; Takei I; Aono Y; Hoshino T; Umemoto M; Shimatsu A; Sanke T; Kuwashima M; Taminato T; Ono J Ann Clin Biochem; 2005 Jan; 42(Pt 1):47-50. PubMed ID: 15802032 [TBL] [Abstract][Full Text] [Related]
9. Standardisation of reporting haemoglobin A1c: adoption of the New Zealand Society for the Study of Diabetes (NZSSD) position statement. Florkowski C; Crooke M N Z Med J; 2010 Mar; 123(1310):43-9. PubMed ID: 20360778 [No Abstract] [Full Text] [Related]
10. HbA1c: a comparison of NGSP with IFCC transformed values. Dhatt GS; Agarwal MM; Bishawi B Clin Chim Acta; 2005 Aug; 358(1-2):81-6. PubMed ID: 16018879 [TBL] [Abstract][Full Text] [Related]
11. [HbA1c--new standardization introduced in Sweden. The new unit is mmol/mol]. Landin-Olsson M; Jeppsson JO; Nordin G Lakartidningen; 2010 Dec; 107(51-52):3282-5. PubMed ID: 21294350 [No Abstract] [Full Text] [Related]
12. Consensus statement on the worldwide standardization of the hemoglobin A1C measurement: the American Diabetes Association, European Association for the Study of Diabetes, International Federation of Clinical Chemistry and Laboratory Medicine, and the International Diabetes Federation. Consensus Committee Diabetes Care; 2007 Sep; 30(9):2399-400. PubMed ID: 17726190 [No Abstract] [Full Text] [Related]
13. Consensus statement on the Worldwide Standardization of the Hemoglobin A1C Measurement: the American Diabetes Association, European Association for the Study of Diabetes, International Federation of Clinical Chemistry and Laboratory Medicine, and the International Diabetes Federation: response to the Consensus Committee. Treviño G Diabetes Care; 2007 Dec; 30(12):e141. PubMed ID: 18042750 [No Abstract] [Full Text] [Related]
16. Levels of glycated haemoglobin A--HbA1c in nondiabetic carriers of haemoglobin O-Arab. Agorasti A; Trivellas T; Papadopoulos V; Konstantinidou D Int J Lab Hematol; 2009 Aug; 31(4):471-4. PubMed ID: 18384394 [No Abstract] [Full Text] [Related]
17. Development of hemoglobin A1c certified reference material by liquid chromatography isotope dilution mass spectrometry. Bi J; Wu L; Yang B; Yang Y; Wang J Anal Bioanal Chem; 2012 Apr; 403(2):549-54. PubMed ID: 22349405 [TBL] [Abstract][Full Text] [Related]