These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

198 related articles for article (PubMed ID: 16473791)

  • 1. Mitral valve replacement with a bioprosthesis: prevention of suture entanglement.
    Talwar S; Mohapatra R; Kumar AS
    Heart Lung Circ; 2006 Feb; 15(1):48-9. PubMed ID: 16473791
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Total preservation of subvalvular apparatus during mitral valve replacement.
    Mediratta N; Sosnowski AW
    Ann Thorac Surg; 1998 Jun; 65(6):1840-1. PubMed ID: 9647131
    [No Abstract]   [Full Text] [Related]  

  • 3. Entanglement of sutures with struts of mitral bioprosthesis: how to prevent it.
    Spampinato N; Iorio D
    Ann Thorac Surg; 1981 May; 31(5):478-9. PubMed ID: 7013720
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transapical transcatheter mitral valve-in-valve implantation in a human.
    Cheung A; Webb JG; Wong DR; Ye J; Masson JB; Carere RG; Lichtenstein SV
    Ann Thorac Surg; 2009 Mar; 87(3):e18-20. PubMed ID: 19231366
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Minimally invasive off-pump valve-in-a-valve implantation: the atrial transcatheter approach for re-operative mitral valve replacement.
    Kempfert J; Blumenstein JM; Borger MA; Linke A; Lehmann S; Pritzwald-Stegmann P; Chu MW; Schuler G; Falk V; Mohr FW; Walther T
    Eur Heart J; 2008 Oct; 29(19):2382-7. PubMed ID: 18567669
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mitral valve disease: if the mitral valve is not reparable/failed repair, is bioprosthesis suitable for replacement?
    Jamieson WR; Gudas VM; Burr LH; Janusz MT; Fradet GJ; Ling H; Germann E; Lichtenstein SV
    Eur J Cardiothorac Surg; 2009 Jan; 35(1):104-10. PubMed ID: 19056294
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Which valve and which size should we use in the valve-on-valve technique for re-do mitral valve surgery?
    Shibata T; Inoue K; Ikuta T; Bito Y; Yoshioka Y; Mizoguchi H
    Interact Cardiovasc Thorac Surg; 2009 Feb; 8(2):206-10. PubMed ID: 19010939
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Failed valve-in-valve transcatheter mitral valve implantation.
    Bruschi G; Botta L; Fratto P; Martinelli L
    Eur J Cardiothorac Surg; 2014 Apr; 45(4):e127. PubMed ID: 24477741
    [No Abstract]   [Full Text] [Related]  

  • 9. Mitral valve apparatus preservation and early bioprosthetic thrombosis: a word of caution.
    Evora PR; Basseto S; Alves Junior L; Rodrigues AJ
    Arq Bras Cardiol; 2011 May; 96(5):e98-9. PubMed ID: 21603797
    [No Abstract]   [Full Text] [Related]  

  • 10. World's first implant of a 23-mm Carpentier-Edwards Perimount Magna mitral bioprosthesis.
    Thalmann M; Gorlitzer M; Grabenwöger M; Moidl R
    J Heart Valve Dis; 2009 May; 18(3):352-3. PubMed ID: 19562846
    [No Abstract]   [Full Text] [Related]  

  • 11. Aortic valve replacement and mitral valve repair as treatment of complications after percutaneous core valve implantation.
    Comoglio C; Boffini M; El Qarra S; Sansone F; D'Amico M; Marra S; Rinaldi M
    J Thorac Cardiovasc Surg; 2009 Oct; 138(4):1025-7. PubMed ID: 19660329
    [No Abstract]   [Full Text] [Related]  

  • 12. Mitral valve replacement and thromboembolic risk.
    Benussi S; Verzini A; Alfieri O
    J Heart Valve Dis; 2004 May; 13 Suppl 1():S81-3. PubMed ID: 15225011
    [No Abstract]   [Full Text] [Related]  

  • 13. Implantation of a modified Freestyle valve with a single inflow suture line: technical patterns and advantages.
    Grandmougin D; Fayad G
    Ann Thorac Surg; 2006 Sep; 82(3):1128-30. PubMed ID: 16928565
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Aortic root replacement with a stentless bioprosthesis in osteogenesis imperfecta.
    Wakiyama H; Okada Y; Kitamura A; Imai Y
    J Heart Valve Dis; 2008 Mar; 17(2):197-9. PubMed ID: 18512491
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The "annular sandwich": a simple method of reinforcing a friable mitral valve annulus.
    Robicsek F
    Ann Thorac Surg; 1999 Jan; 67(1):292. PubMed ID: 10086585
    [No Abstract]   [Full Text] [Related]  

  • 16. Importance of preservation of chordal apparatus in mitral valve replacement.
    Solomon NA; Pranav SK; Naik D; Sukumaran S
    Expert Rev Cardiovasc Ther; 2006 Mar; 4(2):253-61. PubMed ID: 16509820
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Repair of paravalvular leak after a third mitral valve replacement].
    Aizawa K; Tateishi A; Sakano Y; Kaminishi Y; Ohki S; Saito T; Konishi H; Kawada M; Misawa Y
    Kyobu Geka; 2007 Sep; 60(10):903-5. PubMed ID: 17877009
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Surgical technique of aortic valve replacement for small aortic annulus in elderly patients].
    Hata T; Fujiwara K; Furukawa H; Tsushima Y; Yoshitaka H; Kuinose M; Minami H; Ishida A; Tamura K; Totsugawa T; Kanemitsu H; Ozawa M
    Kyobu Geka; 2006 Apr; 59(4):283-7. PubMed ID: 16613145
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multiple valve surgery with beating heart technique.
    Ricci M; Macedo FI; Suarez MR; Brown M; Alba J; Salerno TA
    Ann Thorac Surg; 2009 Feb; 87(2):527-31. PubMed ID: 19161773
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Does posterior transposition of anterior leaflet for complete chordal preservation during mitral valve replacement improve postoperative left ventricular performance?
    Kiris I; Gulmen S; Kuralay E; Ibrisim E
    Eur J Cardiothorac Surg; 2007 Nov; 32(5):820-1; author reply 821-2. PubMed ID: 17825577
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 10.