These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
170 related articles for article (PubMed ID: 16476437)
1. Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1mm I.D. columns. de Villiers A; Lauer H; Szucs R; Goodall S; Sandra P J Chromatogr A; 2006 Apr; 1113(1-2):84-91. PubMed ID: 16476437 [TBL] [Abstract][Full Text] [Related]
2. Practical method transfer from high performance liquid chromatography to ultra-high performance liquid chromatography: the importance of frictional heating. Nováková L; Veuthey JL; Guillarme D J Chromatogr A; 2011 Nov; 1218(44):7971-81. PubMed ID: 21944847 [TBL] [Abstract][Full Text] [Related]
3. Practical assessment of frictional heating effects and thermostat design on the performance of conventional (3 microm and 5 microm) columns in reversed-phase high-performance liquid chromatography. Fallas MM; Hadley MR; McCalley DV J Chromatogr A; 2009 May; 1216(18):3961-9. PubMed ID: 19339017 [TBL] [Abstract][Full Text] [Related]
4. Towards a solution for viscous heating in ultra-high pressure liquid chromatography using intermediate cooling. Broeckhoven K; Billen J; Verstraeten M; Choikhet K; Dittmann M; Rozing G; Desmet G J Chromatogr A; 2010 Mar; 1217(13):2022-31. PubMed ID: 20181348 [TBL] [Abstract][Full Text] [Related]
5. Ultra high pressure liquid chromatography. Column permeability and changes of the eluent properties. Gritti F; Guiochon G J Chromatogr A; 2008 Apr; 1187(1-2):165-79. PubMed ID: 18313063 [TBL] [Abstract][Full Text] [Related]
6. Complete temperature profiles in ultra-high-pressure liquid chromatography columns. Gritti F; Guiochon G Anal Chem; 2008 Jul; 80(13):5009-20. PubMed ID: 18529067 [TBL] [Abstract][Full Text] [Related]
7. Consequences of the radial heterogeneity of the column temperature at high mobile phase velocity. Gritti F; Guiochon G J Chromatogr A; 2007 Sep; 1166(1-2):47-60. PubMed ID: 17720174 [TBL] [Abstract][Full Text] [Related]
8. Effects of the thermal heterogeneity of the column on chromatographic results. Gritti F; Guiochon G J Chromatogr A; 2006 Oct; 1131(1-2):151-65. PubMed ID: 16919645 [TBL] [Abstract][Full Text] [Related]
9. Theoretical calculation of the retention enthalpy effect on the viscous heat dissipation band broadening in high performance liquid chromatography columns with a fixed wall temperature. Desmet G J Chromatogr A; 2006 May; 1116(1-2):89-96. PubMed ID: 16597444 [TBL] [Abstract][Full Text] [Related]
10. Modeling of thermal processes in high pressure liquid chromatography: II. Thermal heterogeneity at very high pressures. Kaczmarski K; Gritti F; Kostka J; Guiochon G J Chromatogr A; 2009 Sep; 1216(38):6575-86. PubMed ID: 19665717 [TBL] [Abstract][Full Text] [Related]
11. Measurement of the axial and radial temperature profiles of a chromatographic column. Influence of thermal insulation on column efficiency. Gritti F; Guiochon G J Chromatogr A; 2007 Jan; 1138(1-2):141-57. PubMed ID: 17141792 [TBL] [Abstract][Full Text] [Related]
12. Influence of viscous friction heating on the efficiency of columns operated under very high pressures. Gritti F; Martin M; Guiochon G Anal Chem; 2009 May; 81(9):3365-84. PubMed ID: 19361228 [TBL] [Abstract][Full Text] [Related]
13. Modeling of thermal processes in high pressure liquid chromatography: I. Low pressure onset of thermal heterogeneity. Kaczmarski K; Kostka J; Zapała W; Guiochon G J Chromatogr A; 2009 Sep; 1216(38):6560-74. PubMed ID: 19640545 [TBL] [Abstract][Full Text] [Related]
14. Numerical modeling of elution peak profiles in supercritical fluid chromatography. Part I--elution of an unretained tracer. Kaczmarski K; Poe DP; Guiochon G J Chromatogr A; 2010 Oct; 1217(42):6578-87. PubMed ID: 20813372 [TBL] [Abstract][Full Text] [Related]
15. High throughput liquid chromatography with sub-2 microm particles at high pressure and high temperature. Nguyen DT; Guillarme D; Heinisch S; Barrioulet MP; Rocca JL; Rudaz S; Veuthey JL J Chromatogr A; 2007 Oct; 1167(1):76-84. PubMed ID: 17765255 [TBL] [Abstract][Full Text] [Related]
16. Investigation of the validity of the kinetic plot method to predict the performance of coupled column systems operated at very high pressures under different thermal conditions. Cabooter D; Lestremau F; de Villiers A; Broeckhoven K; Lynen F; Sandra P; Desmet G J Chromatogr A; 2009 May; 1216(18):3895-903. PubMed ID: 19285677 [TBL] [Abstract][Full Text] [Related]
17. Kinetic plot equations for evaluating the real performance of the combined use of high temperature and ultra-high pressure in liquid chromatography. Application to commercial instruments and 2.1 and 1 mm I.D. columns. Heinisch S; Desmet G; Clicq D; Rocca JL J Chromatogr A; 2008 Sep; 1203(2):124-36. PubMed ID: 18675984 [TBL] [Abstract][Full Text] [Related]
18. Performance of new prototype packed columns for very high pressure liquid chromatography. Gritti F; Guiochon G J Chromatogr A; 2010 Feb; 1217(9):1485-95. PubMed ID: 20060978 [TBL] [Abstract][Full Text] [Related]
19. Estimation of the effects of longitudinal temperature gradients caused by frictional heating on the solute retention using fully porous and superficially porous sub-2μm materials. Fekete S; Fekete J; Guillarme D J Chromatogr A; 2014 Sep; 1359():124-30. PubMed ID: 25069746 [TBL] [Abstract][Full Text] [Related]
20. Fundamental chromatographic equations designed for columns packed with very fine particles and operated at very high pressures. Applications to the prediction of elution times and the column efficiencies. Gritti F; Guiochon G J Chromatogr A; 2008 Oct; 1206(2):113-22. PubMed ID: 18775540 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]