BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

236 related articles for article (PubMed ID: 16479558)

  • 1. Comparison between external and internal standard calibration in the validation of an analytical method for 1-hydroxypyrene in human urine by high-performance liquid chromatography/tandem mass spectrometry.
    Pigini D; Cialdella AM; Faranda P; Tranfo G
    Rapid Commun Mass Spectrom; 2006; 20(6):1013-8. PubMed ID: 16479558
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Direct measurement of the glucuronide conjugate of 1-hydroxypyrene in human urine by using liquid chromatography with tandem mass spectrometry.
    Kakimoto K; Toriba A; Ohno T; Ueno M; Kameda T; Tang N; Hayakawa K
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 May; 867(2):259-63. PubMed ID: 18463007
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A simple analytical method of determining 1-hydroxypyrene glucuronide in human urine by isotope dilution with ultra performance liquid chromatography-tandem mass spectrometry.
    Li M; Wang Q; Zhu J; Li N; Zou X
    Anal Bioanal Chem; 2017 Feb; 409(6):1513-1518. PubMed ID: 27888306
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The determination of occupational exposure to polycyclic aromatic hydrocarbons by the analysis of 1-hydroxypyrene in urine using a simple automated online column switching device and high-performance liquid chromatography.
    Hu J; Hurst JA; O'Donnell GE
    J Anal Toxicol; 2012 Jun; 36(5):334-9. PubMed ID: 22582268
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [An improved high performance liquid chromatography method for determination of 1-hydroxypyrene in urine].
    Li X; Leng S; Guo J; Guan L
    Wei Sheng Yan Jiu; 2003 Nov; 32(6):616-7. PubMed ID: 14963919
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous determination of urinary hydroxylated metabolites of naphthalene, fluorene, phenanthrene, fluoranthene and pyrene as multiple biomarkers of exposure to polycyclic aromatic hydrocarbons.
    Chetiyanukornkul T; Toriba A; Kameda T; Tang N; Hayakawa K
    Anal Bioanal Chem; 2006 Oct; 386(3):712-8. PubMed ID: 16924381
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The use of chemical derivatization to enhance liquid chromatography/tandem mass spectrometric determination of 1-hydroxypyrene, a biomarker for polycyclic aromatic hydrocarbons in human urine.
    Li Y; Li AC; Shi H; Zhou S; Shou WZ; Jiang X; Naidong W; Lauterbach JH
    Rapid Commun Mass Spectrom; 2005; 19(22):3331-8. PubMed ID: 16235235
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Detection of 1-hydroxypyrene in urine by direct fluorometric analysis on a solid sorbing phase. Validation and application of the method to biological monitoring of PAH-exposed persons.
    Lamotte M; Belfutmi R; Fornier De Violet P; Garrigues P; Lafontaine M; Dumas C
    Anal Bioanal Chem; 2003 Jul; 376(6):816-21. PubMed ID: 12827334
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Identification of 1-hydroxypyrene glucuronide as a major pyrene metabolite in human urine by synchronous fluorescence spectroscopy and gas chromatography-mass spectrometry.
    Strickland PT; Kang D; Bowman ED; Fitzwilliam A; Downing TE; Rothman N; Groopman JD; Weston A
    Carcinogenesis; 1994 Mar; 15(3):483-7. PubMed ID: 8118933
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the determination of phenolic polycyclic aromatic hydrocarbons (OH-PAH) in urine of non-smokers and smokers.
    Ramsauer B; Sterz K; Hagedorn HW; Engl J; Scherer G; McEwan M; Errington G; Shepperd J; Cheung F
    Anal Bioanal Chem; 2011 Jan; 399(2):877-89. PubMed ID: 21046075
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of 1-hydroxypyrene in human urine by high-performance liquid chromatography with fluorescence detection using a deuterated internal standard.
    Chetiyanukornkul T; Toriba A; Kizu R; Makino T; Nakazawa H; Hayakaw K
    J Chromatogr A; 2002 Jun; 961(1):107-12. PubMed ID: 12186380
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 1-Hydroxypyrene as a biomarker of PAH exposure in the marine polychaete Nereis diversicolor.
    Tairova ZM; Giessing AM; Hansen R; Andersen O
    Mar Environ Res; 2009 Feb; 67(1):38-46. PubMed ID: 19058843
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fast and simultaneous determination of urinary 8-hydroxy-2'-deoxyguanosine and ten monohydroxylated polycyclic aromatic hydrocarbons by liquid chromatography/tandem mass spectrometry.
    Fan R; Wang D; Ramage R; She J
    Chem Res Toxicol; 2012 Feb; 25(2):491-9. PubMed ID: 22250670
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of three analytical methods for 1-hydroxypyrene glucuronide in urine after non-occupational exposure to polycyclic aromatic hydrocarbons.
    Lee CK; Cho SH; Kang JW; Lee SJ; Ju YS; Sung J; Strickland PT; Kang D
    Toxicol Lett; 1999 Sep; 108(2-3):209-15. PubMed ID: 10511264
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of 1-hydroxypyrene, 1- and 2-hydroxynaphthalene, 3-hydroxybenzo[a]pyrene and 6-hydroxynitropyrene by HPLC-MS/MS in human urine as exposure biomarkers for environmental and occupational surveys.
    Raponi F; Bauleo L; Ancona C; Forastiere F; Paci E; Pigini D; Tranfo G
    Biomarkers; 2017 Sep; 22(6):575-583. PubMed ID: 27775446
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fast simultaneous determination of urinary 1-hydroxypyrene and 3-hydroxybenzo[a]pyrene by liquid chromatography-tandem mass spectrometry.
    Fan R; Dong Y; Zhang W; Wang Y; Yu Z; Sheng G; Fu J
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 May; 836(1-2):92-7. PubMed ID: 16617038
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A rapid and simple method for the analysis of 1-hydroxypyrene glucuronide: a potential biomarker for polycyclic aromatic hydrocarbon exposure.
    Singh R; Tucek M; Maxa K; Tenglerová J; Weyand EH
    Carcinogenesis; 1995 Dec; 16(12):2909-15. PubMed ID: 8603463
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 1,2-Dimethylimidazole-4-sulfonyl chloride, a novel derivatization reagent for the analysis of phenolic compounds by liquid chromatography electrospray tandem mass spectrometry: application to 1-hydroxypyrene in human urine.
    Xu L; Spink DC
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Aug; 855(2):159-65. PubMed ID: 17524972
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of 1-hydroxypyrene in human urine by high-performance liquid chromatography.
    Hansen AM; Poulsen OM; Christensen JM; Hansen SH
    J Anal Toxicol; 1993; 17(1):38-41. PubMed ID: 8429626
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Indacaterol determination in human urine: validation of a liquid-liquid extraction and liquid chromatography-tandem mass spectrometry analytical method.
    Ammari WG; Al-Qadhi Z; Khalil M; Tayyem R; Qammaz S; Oriquat G; Basheti IA; Chrystyn H
    J Aerosol Med Pulm Drug Deliv; 2015 Jun; 28(3):202-10. PubMed ID: 25229261
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.