439 related articles for article (PubMed ID: 16480898)
1. Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI.
Chen NK; Oshio K; Panych LP
Neuroimage; 2006 Jun; 31(2):609-22. PubMed ID: 16480898
[TBL] [Abstract][Full Text] [Related]
2. EPI image reconstruction with correction of distortion and signal losses.
Liu G; Ogawa S
J Magn Reson Imaging; 2006 Sep; 24(3):683-9. PubMed ID: 16892198
[TBL] [Abstract][Full Text] [Related]
3. A simple simultaneous geometric and intensity correction method for echo-planar imaging by EPI-based phase modulation.
Chiou JY; Ahn CB; Muftuler LT; Nalcioglu O
IEEE Trans Med Imaging; 2003 Feb; 22(2):200-5. PubMed ID: 12715996
[TBL] [Abstract][Full Text] [Related]
4. Single-shot compensation of image distortions and BOLD contrast optimization using multi-echo EPI for real-time fMRI.
Weiskopf N; Klose U; Birbaumer N; Mathiak K
Neuroimage; 2005 Feb; 24(4):1068-79. PubMed ID: 15670684
[TBL] [Abstract][Full Text] [Related]
5. Image distortion correction in fMRI: A quantitative evaluation.
Hutton C; Bork A; Josephs O; Deichmann R; Ashburner J; Turner R
Neuroimage; 2002 May; 16(1):217-40. PubMed ID: 11969330
[TBL] [Abstract][Full Text] [Related]
6. Reduction of susceptibility-induced signal losses in multi-gradient-echo images: application to improved visualization of the subthalamic nucleus.
Volz S; Hattingen E; Preibisch C; Gasser T; Deichmann R
Neuroimage; 2009 May; 45(4):1135-43. PubMed ID: 19349229
[TBL] [Abstract][Full Text] [Related]
7. How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging.
Andersson JL; Skare S; Ashburner J
Neuroimage; 2003 Oct; 20(2):870-88. PubMed ID: 14568458
[TBL] [Abstract][Full Text] [Related]
8. Doubling the resolution of echo-planar brain imaging by acquisition of two k-space lines per gradient reversal using TRAIL.
Priest AN; De Vita E; Ordidge RJ
NMR Biomed; 2008 Feb; 21(2):79-88. PubMed ID: 17506114
[TBL] [Abstract][Full Text] [Related]
9. Susceptibility-matched envelope for the correction of EPI artifacts.
Neufeld A; Assaf Y; Graif M; Hendler T; Navon G
Magn Reson Imaging; 2005 Nov; 23(9):947-51. PubMed ID: 16310110
[TBL] [Abstract][Full Text] [Related]
10. A new EPI-based dynamic field mapping method: application to retrospective geometrical distortion corrections.
Lamberton F; Delcroix N; Grenier D; Mazoyer B; Joliot M
J Magn Reson Imaging; 2007 Sep; 26(3):747-55. PubMed ID: 17729370
[TBL] [Abstract][Full Text] [Related]
11. Investigating the benefits of multi-echo EPI for fMRI at 7 T.
Poser BA; Norris DG
Neuroimage; 2009 May; 45(4):1162-72. PubMed ID: 19349231
[TBL] [Abstract][Full Text] [Related]
12. Improved B(0) field map estimation for high field EPI.
Poot DH; Pintjens W; Verhoye M; Van Der Linden A; Sijbers J
Magn Reson Imaging; 2010 Apr; 28(3):441-50. PubMed ID: 20133097
[TBL] [Abstract][Full Text] [Related]
13. Interleaved snapshot echo planar imaging of mouse brain at 7.0 T.
Guilfoyle DN; Hrabe J
NMR Biomed; 2006 Feb; 19(1):108-15. PubMed ID: 16411168
[TBL] [Abstract][Full Text] [Related]
14. EPI distortion correction from a simultaneously acquired distortion map using TRAIL.
Priest AN; De Vita E; Thomas DL; Ordidge RJ
J Magn Reson Imaging; 2006 Apr; 23(4):597-603. PubMed ID: 16514595
[TBL] [Abstract][Full Text] [Related]
15. Automatic correction of echo-planar imaging (EPI) ghosting artifacts in real-time interactive cardiac MRI using sensitivity encoding.
Kim YC; Nielsen JF; Nayak KS
J Magn Reson Imaging; 2008 Jan; 27(1):239-45. PubMed ID: 18050332
[TBL] [Abstract][Full Text] [Related]
16. Computer simulation studies of the effects of dynamic shimming on susceptibility artifacts in EPI at high field.
Zhao Y; Anderson AW; Gore JC
J Magn Reson; 2005 Mar; 173(1):10-22. PubMed ID: 15705507
[TBL] [Abstract][Full Text] [Related]
17. Radial echo-planar imaging.
Silva AC; Barbier EL; Lowe IJ; Koretsky AP
J Magn Reson; 1998 Nov; 135(1):242-7. PubMed ID: 9799701
[TBL] [Abstract][Full Text] [Related]
18. Simple correction method for k-space trajectory deviations in MRI.
Duyn JH; Yang Y; Frank JA; van der Veen JW
J Magn Reson; 1998 May; 132(1):150-3. PubMed ID: 9615415
[TBL] [Abstract][Full Text] [Related]
19. Diffusion-weighted imaging in patients with acute brain ischemia at 3 T: current possibilities and future perspectives comparing conventional echoplanar diffusion-weighted imaging and fast spin echo diffusion-weighted imaging sequences using BLADE (PROPELLER).
Fries P; Runge VM; Kirchin MA; Stemmer A; Naul LG; Wiliams KD; Reith W; Bücker A; Schneider G
Invest Radiol; 2009 Jun; 44(6):351-9. PubMed ID: 19363447
[TBL] [Abstract][Full Text] [Related]
20. Positive or negative blips? The effect of phase encoding scheme on susceptibility-induced signal losses in EPI.
De Panfilis C; Schwarzbauer C
Neuroimage; 2005 Mar; 25(1):112-21. PubMed ID: 15734348
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]