371 related articles for article (PubMed ID: 16495612)
1. The PILATUS 1M detector.
Broennimann Ch; Eikenberry EF; Henrich B; Horisberger R; Huelsen G; Pohl E; Schmitt B; Schulze-Briese C; Suzuki M; Tomizaki T; Toyokawa H; Wagner A
J Synchrotron Radiat; 2006 Mar; 13(Pt 2):120-30. PubMed ID: 16495612
[TBL] [Abstract][Full Text] [Related]
2. A 3 x 6 arrayed CCD X-ray detector for continuous rotation method in macromolecular crystallography.
Ito K; Gaponov Y; Sakabe N; Amemiya Y
J Synchrotron Radiat; 2007 Jan; 14(Pt 1):144-50. PubMed ID: 17211082
[TBL] [Abstract][Full Text] [Related]
3. Beamline X29: a novel undulator source for X-ray crystallography.
Shi W; Robinson H; Sullivan M; Abel D; Toomey J; Berman LE; Lynch D; Rosenbaum G; Rakowsky G; Rock L; Nolan B; Shea-McCarthy G; Schneider D; Johnson E; Sweet RM; Chance MR
J Synchrotron Radiat; 2006 Sep; 13(Pt 5):365-72. PubMed ID: 16924132
[TBL] [Abstract][Full Text] [Related]
4. EIGER detector: application in macromolecular crystallography.
Casanas A; Warshamanage R; Finke AD; Panepucci E; Olieric V; Nöll A; Tampé R; Brandstetter S; Förster A; Mueller M; Schulze-Briese C; Bunk O; Wang M
Acta Crystallogr D Struct Biol; 2016 Sep; 72(Pt 9):1036-48. PubMed ID: 27599736
[TBL] [Abstract][Full Text] [Related]
5. Advanced beamline automation for biological crystallography experiments.
Cork C; O'Neill J; Taylor J; Earnest T
Acta Crystallogr D Biol Crystallogr; 2006 Aug; 62(Pt 8):852-8. PubMed ID: 16855300
[TBL] [Abstract][Full Text] [Related]
6. Development of a real-time timing-shutter performance monitor for protein crystallography.
Alkire RW; Molitsky M; Rotella FJ; Duke NE; De Lurgio PM; Lee J; Madden T
J Synchrotron Radiat; 2006 Sep; 13(Pt 5):408-10. PubMed ID: 16924138
[TBL] [Abstract][Full Text] [Related]
7. A large-area CMOS imager as an X-ray detector for synchrotron radiation experiments.
Yagi N; Yamamoto M; Uesugi K; Inoue K
J Synchrotron Radiat; 2004 Jul; 11(Pt 4):347-52. PubMed ID: 15211042
[TBL] [Abstract][Full Text] [Related]
8. Automation of the EMBL Hamburg protein crystallography beamline BW7B.
Pohl E; Ristau U; Gehrmann T; Jahn D; Robrahn B; Malthan D; Dobler H; Hermes C
J Synchrotron Radiat; 2004 Sep; 11(Pt 5):372-7. PubMed ID: 15310952
[TBL] [Abstract][Full Text] [Related]
9. Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector.
Ejdrup T; Lemke HT; Haldrup K; Nielsen TN; Arms DA; Walko DA; Miceli A; Landahl EC; Dufresne EM; Nielsen MM
J Synchrotron Radiat; 2009 May; 16(Pt 3):387-90. PubMed ID: 19395803
[TBL] [Abstract][Full Text] [Related]
10. Performance of single-photon-counting PILATUS detector modules.
Kraft P; Bergamaschi A; Broennimann Ch; Dinapoli R; Eikenberry EF; Henrich B; Johnson I; Mozzanica A; Schlepütz CM; Willmott PR; Schmitt B
J Synchrotron Radiat; 2009 May; 16(Pt 3):368-75. PubMed ID: 19395800
[TBL] [Abstract][Full Text] [Related]
11. The ID23-1 structural biology beamline at the ESRF.
Nurizzo D; Mairs T; Guijarro M; Rey V; Meyer J; Fajardo P; Chavanne J; Biasci JC; McSweeney S; Mitchell E
J Synchrotron Radiat; 2006 May; 13(Pt 3):227-38. PubMed ID: 16645249
[TBL] [Abstract][Full Text] [Related]
12. Fast two-dimensional detection for X-ray photon correlation spectroscopy using the PILATUS detector.
Westermeier F; Autenrieth T; Gutt C; Leupold O; Duri A; Menzel A; Johnson I; Broennimann C; Grübel G
J Synchrotron Radiat; 2009 Sep; 16(Pt 5):687-9. PubMed ID: 19713644
[TBL] [Abstract][Full Text] [Related]
13. A high-throughput structural biology/proteomics beamline at the SRS on a new multipole wiggler.
Cianci M; Antonyuk S; Bliss N; Bailey MW; Buffey SG; Cheung KC; Clarke JA; Derbyshire GE; Ellis MJ; Enderby MJ; Grant AF; Holbourn MP; Laundy D; Nave C; Ryder R; Stephenson P; Helliwell JR; Hasnain SS
J Synchrotron Radiat; 2005 Jul; 12(Pt 4):455-66. PubMed ID: 15968122
[TBL] [Abstract][Full Text] [Related]
14. 14C autoradiography with an energy-sensitive silicon pixel detector.
Esposito M; Mettivier G; Russo P
Phys Med Biol; 2011 Apr; 56(7):1947-65. PubMed ID: 21364264
[TBL] [Abstract][Full Text] [Related]
15. Efficient use of synchrotron radiation for macromolecular diffraction data collection.
Dauter Z
Prog Biophys Mol Biol; 2005 Oct; 89(2):153-72. PubMed ID: 15910916
[TBL] [Abstract][Full Text] [Related]
16. Instrumentation for synchrotron-radiation macromolecular crystallography.
Girard E; Legrand P; Roudenko O; Roussier L; Gourhant P; Gibelin J; Dalle D; Ounsy M; Thompson AW; Svensson O; Cordier MO; Robin S; Quiniou R; Steyer JP
Acta Crystallogr D Biol Crystallogr; 2006 Jan; 62(Pt 1):12-8. PubMed ID: 16369089
[TBL] [Abstract][Full Text] [Related]
17. A pixel detector-based single photon-counting system as fast spectrometer for diagnostic X-ray beams.
Carpentieri C; Bisogni MG; Del Guerra A; Delogu P; Fantacci ME; Fogli J; Marchi A; Marzulli V; Rosso V; Stefanini A; Tofani A
Radiat Prot Dosimetry; 2008; 129(1-3):119-22. PubMed ID: 18487616
[TBL] [Abstract][Full Text] [Related]
18. The materials science X-ray beamline BL8 at the DELTA storage ring.
Lützenkirchen-Hecht D; Wagner R; Haake U; Watenphul A; Frahm R
J Synchrotron Radiat; 2009 Mar; 16(Pt 2):264-72. PubMed ID: 19240339
[TBL] [Abstract][Full Text] [Related]
19. Energy resolution of the CdTe-XPAD detector: calibration and potential for Laue diffraction measurements on protein crystals.
Medjoubi K; Thompson A; Bérar JF; Clemens JC; Delpierre P; Da Silva P; Dinkespiler B; Fourme R; Gourhant P; Guimaraes B; Hustache S; Idir M; Itié JP; Legrand P; Menneglier C; Mercere P; Picca F; Samama JP
J Synchrotron Radiat; 2012 May; 19(Pt 3):323-31. PubMed ID: 22514165
[TBL] [Abstract][Full Text] [Related]
20. A new highly integrated sample environment for protein crystallography.
Jacquamet L; Ohana J; Joly J; Legrand P; Kahn R; Borel F; Pirocchi M; Charrault P; Carpentier P; Ferrer JL
Acta Crystallogr D Biol Crystallogr; 2004 May; 60(Pt 5):888-94. PubMed ID: 15103134
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]