194 related articles for article (PubMed ID: 16516460)
1. Formaldehyde assay by capacitance versus voltage and impedance measurements using bi-layer bio-recognition membrane.
Ben Ali M; Korpan Y; Gonchar M; El'skaya A; Maaref MA; Jaffrezic-Renault N; Martelet C
Biosens Bioelectron; 2006 Dec; 22(5):575-81. PubMed ID: 16516460
[TBL] [Abstract][Full Text] [Related]
2. Formaldehyde-sensitive sensor based on recombinant formaldehyde dehydrogenase using capacitance versus voltage measurements.
Ben Ali M; Gonchar M; Gayda G; Paryzhak S; Maaref MA; Jaffrezic-Renault N; Korpan Y
Biosens Bioelectron; 2007 Jun; 22(12):2790-5. PubMed ID: 17098416
[TBL] [Abstract][Full Text] [Related]
3. On-line detection of atmospheric formaldehyde by a conductometric biosensor.
Vianello F; Boscolo-Chio R; Signorini S; Rigo A
Biosens Bioelectron; 2007 Jan; 22(6):920-5. PubMed ID: 16678399
[TBL] [Abstract][Full Text] [Related]
4. Miniaturised enzymatic conductometric biosensor with Nafion membrane for the direct determination of formaldehyde in water samples.
Nguyen-Boisse TT; Saulnier J; Jaffrezic-Renault N; Lagarde F
Anal Bioanal Chem; 2014 Feb; 406(4):1039-48. PubMed ID: 23907681
[TBL] [Abstract][Full Text] [Related]
5. Reagentless amperometric formaldehyde-selective biosensors based on the recombinant yeast formaldehyde dehydrogenase.
Demkiv O; Smutok O; Paryzhak S; Gayda G; Sultanov Y; Guschin D; Shkil H; Schuhmann W; Gonchar M
Talanta; 2008 Aug; 76(4):837-46. PubMed ID: 18656667
[TBL] [Abstract][Full Text] [Related]
6. Characterisation of capacitive field-effect sensors with a nanocrystalline-diamond film as transducer material for multi-parameter sensing.
Abouzar MH; Poghossian A; Razavi A; Williams OA; Bijnens N; Wagner P; Schöning MJ
Biosens Bioelectron; 2009 Jan; 24(5):1298-304. PubMed ID: 18801654
[TBL] [Abstract][Full Text] [Related]
7. Amperometric and impedimetric characterization of a glutamate biosensor based on Nafion and a methyl viologen modified glassy carbon electrode.
Maalouf R; Chebib H; Saïkali Y; Vittori O; Sigaud M; Jaffrezic-Renault N
Biosens Bioelectron; 2007 May; 22(11):2682-8. PubMed ID: 17161943
[TBL] [Abstract][Full Text] [Related]
8. A novel method for glucose determination based on electrochemical impedance spectroscopy using glucose oxidase self-assembled biosensor.
Shervedani RK; Mehrjardi AH; Zamiri N
Bioelectrochemistry; 2006 Oct; 69(2):201-8. PubMed ID: 16580891
[TBL] [Abstract][Full Text] [Related]
9. Biochemical gas sensor (bio-sniffer) for ultrahigh-sensitive gaseous formaldehyde monitoring.
Kudo H; Suzuki Y; Gessei T; Takahashi D; Arakawa T; Mitsubayashi K
Biosens Bioelectron; 2010 Oct; 26(2):854-8. PubMed ID: 20810270
[TBL] [Abstract][Full Text] [Related]
10. Penicillin biosensor based on a capacitive field-effect structure functionalized with a dendrimer/carbon nanotube multilayer.
Siqueira JR; Abouzar MH; Poghossian A; Zucolotto V; Oliveira ON; Schöning MJ
Biosens Bioelectron; 2009 Oct; 25(2):497-501. PubMed ID: 19651505
[TBL] [Abstract][Full Text] [Related]
11. A tris(2,2'-bipyridyl)cobalt(III)-bovine serum albumin composite membrane for biosensors.
Zhuo Y; Yuan R; Chai Y; Sun A; Zhang Y; Yang J
Biomaterials; 2006 Nov; 27(31):5420-9. PubMed ID: 16843525
[TBL] [Abstract][Full Text] [Related]
12. Direct detection of formaldehyde in air by a novel NAD+- and glutathione-independent formaldehyde dehydrogenase-based biosensor.
Achmann S; Hermann M; Hilbrig F; Jérôme V; Hämmerle M; Freitag R; Moos R
Talanta; 2008 May; 75(3):786-91. PubMed ID: 18585147
[TBL] [Abstract][Full Text] [Related]
13. A high sensitivity amperometric biosensor using a monomolecular layer of laccase as biorecognition element.
Vianello F; Cambria A; Ragusa S; Cambria MT; Zennaro L; Rigo A
Biosens Bioelectron; 2004 Sep; 20(2):315-21. PubMed ID: 15308236
[TBL] [Abstract][Full Text] [Related]
14. A novel nitrite biosensor based on conductometric electrode modified with cytochrome c nitrite reductase composite membrane.
Zhang Z; Xia S; Leonard D; Jaffrezic-Renault N; Zhang J; Bessueille F; Goepfert Y; Wang X; Chen L; Zhu Z; Zhao J; Almeida MG; Silveira CM
Biosens Bioelectron; 2009 Feb; 24(6):1574-9. PubMed ID: 18804367
[TBL] [Abstract][Full Text] [Related]
15. Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode.
Wu BY; Hou SH; Yin F; Li J; Zhao ZX; Huang JD; Chen Q
Biosens Bioelectron; 2007 Jan; 22(6):838-44. PubMed ID: 16675215
[TBL] [Abstract][Full Text] [Related]
16. Electrochemical characterization of biosensor based on nitrite reductase and methyl viologen co-immobilized glassy carbon electrode.
Quan D; Min DG; Cha GS; Nam H
Bioelectrochemistry; 2006 Oct; 69(2):267-75. PubMed ID: 16713751
[TBL] [Abstract][Full Text] [Related]
17. Investigation and evaluation of a method for determination of ethanol with the SIRE Biosensor P100, using alcohol dehydrogenase as recognition element.
Svensson K; Bülow L; Kriz D; Krook M
Biosens Bioelectron; 2005 Nov; 21(5):705-11. PubMed ID: 16242608
[TBL] [Abstract][Full Text] [Related]
18. A novel reagentless amperometric immunosensor based on gold nanoparticles/TMB/Nafion-modified electrode.
Wu Y; Zheng J; Li Z; Zhao Y; Zhang Y
Biosens Bioelectron; 2009 Jan; 24(5):1389-93. PubMed ID: 18799302
[TBL] [Abstract][Full Text] [Related]
19. Biosensing nitrite using the system nitrite redutase/Nafion/methyl viologen--a voltammetric study.
Almeida MG; Silveira CM; Moura JJ
Biosens Bioelectron; 2007 May; 22(11):2485-92. PubMed ID: 17101271
[TBL] [Abstract][Full Text] [Related]
20. Enantioselective screen-printed amperometric biosensor for the determination of D-amino acids.
Wcisło M; Compagnone D; Trojanowicz M
Bioelectrochemistry; 2007 Sep; 71(1):91-8. PubMed ID: 17071143
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]