345 related articles for article (PubMed ID: 16516902)
21. Challenges encountered in extending the sensitivity of US Environmental Protection Agency Method 314.0 for perchlorate in drinking water.
Wagner HP; Suarez FX; Pepich BV; Hautman DP; Munch DJ
J Chromatogr A; 2004 Jun; 1039(1-2):97-104. PubMed ID: 15250409
[TBL] [Abstract][Full Text] [Related]
22. Development of drinking water standards for perchlorate in the United States.
Kucharzyk KH; Crawford RL; Cosens B; Hess TF
J Environ Manage; 2009; 91(2):303-10. PubMed ID: 19850401
[TBL] [Abstract][Full Text] [Related]
23. Determination of trace level perchlorate in drinking water and ground water by ion chromatography.
Jackson PE; Laikhtman M; Rohrer JS
J Chromatogr A; 1999 Jul; 850(1-2):131-5. PubMed ID: 10457473
[TBL] [Abstract][Full Text] [Related]
24. [Simultaneous determination of bromate and perchlorate in vegetable by ion chromatography tandem mass spectrometry].
Yang J; Yang Y; Zhang J; Shao B; Wu Y
Wei Sheng Yan Jiu; 2012 Mar; 41(2):273-8. PubMed ID: 22611940
[TBL] [Abstract][Full Text] [Related]
25. Trace determination of perchlorate using electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity detection.
Kiplagat IK; Doan TK; Kubáň P; Boček P
Electrophoresis; 2011 Nov; 32(21):3008-15. PubMed ID: 22002888
[TBL] [Abstract][Full Text] [Related]
26. Suppressed anion chromatography using mixed zwitter-ionic and carbonate eluents.
Chen Y; Jing L; Li X; Zhu Y
J Chromatogr A; 2006 Jun; 1118(1):3-11. PubMed ID: 16458910
[TBL] [Abstract][Full Text] [Related]
27. Neonatal thyroid-stimulating hormone level and perchlorate in drinking water.
Li FX; Byrd DM; Deyhle GM; Sesser DE; Skeels MR; Katkowsky SR; Lamm SH
Teratology; 2000 Dec; 62(6):429-31. PubMed ID: 11091365
[TBL] [Abstract][Full Text] [Related]
28. A bioassay for the detection of perchlorate in the ppb range.
Heinnickel M; Smith SC; Koo J; O'Connor SM; Coates JD
Environ Sci Technol; 2011 Apr; 45(7):2958-64. PubMed ID: 21384912
[TBL] [Abstract][Full Text] [Related]
29. Perchlorate in tap water, groundwater, surface waters, and bottled water from China and its association with other inorganic anions and with disinfection byproducts.
Wu Q; Zhang T; Sun H; Kannan K
Arch Environ Contam Toxicol; 2010 Apr; 58(3):543-50. PubMed ID: 20162260
[TBL] [Abstract][Full Text] [Related]
30. Development of retention mechanism for the separation of carboxylic acids and inorganic anions in cryptand-based ion chromatography.
Lukács D; Horváth K; Hajós P
J Chromatogr A; 2020 Jun; 1621():461066. PubMed ID: 32299623
[TBL] [Abstract][Full Text] [Related]
31. Determination of glycerophosphate and other anions in dentifrices by ion chromatography.
Chen Y; Ye M; Cui H; Wu F; Zhu Y; Fritz JS
J Chromatogr A; 2006 Jun; 1118(1):155-9. PubMed ID: 16516904
[TBL] [Abstract][Full Text] [Related]
32. Equilibrium dialysis and ultrafiltration investigations of perchlorate removal from aqueous solution using poly(diallyldimethylammonium) chloride.
Roach JD; Tush D
Water Res; 2008 Feb; 42(4-5):1204-10. PubMed ID: 17915279
[TBL] [Abstract][Full Text] [Related]
33. A method for assaying perchlorate concentration in microbial cultures using the fluorescent dye resazurin.
Kucharzyk KH; Crawford RL; Paszczynski AJ; Hess TF
J Microbiol Methods; 2010 Apr; 81(1):26-32. PubMed ID: 20109501
[TBL] [Abstract][Full Text] [Related]
34. Determination of trace concentrations of bromate in municipal and bottled drinking waters using a hydroxide-selective column with ion chromatography.
De Borba BM; Rohrer JS; Pohl CA; Saini C
J Chromatogr A; 2005 Aug; 1085(1):23-32. PubMed ID: 16106843
[TBL] [Abstract][Full Text] [Related]
35. Performance of poly(vinyl alcohol) gel columns on the ion chromatographic determination of perchlorate in fertilizers.
De B; Urbansky ET
J Environ Monit; 2002 Feb; 4(1):149-55. PubMed ID: 11871696
[TBL] [Abstract][Full Text] [Related]
36. High performance ion chromatography of haloacetic acids on macrocyclic cryptand anion exchanger.
Bruzzoniti MC; De Carlo RM; Horvath K; Perrachon D; Prelle A; Tófalvi R; Sarzanini C; Hajós P
J Chromatogr A; 2008 Apr; 1187(1-2):188-96. PubMed ID: 18304560
[TBL] [Abstract][Full Text] [Related]
37. Raman spectroscopic detection for perchlorate at low concentrations.
Gu B; Tio J; Wang W; Ku YK; Dai S
Appl Spectrosc; 2004 Jun; 58(6):741-4. PubMed ID: 15198828
[TBL] [Abstract][Full Text] [Related]
38. Characterization of a microparticulate strong anion-exchanger in the HPLC of acidic drugs.
Morgan PE; Hanna-Brown M; Flanagan RJ
Biomed Chromatogr; 2006 Aug; 20(8):765-73. PubMed ID: 16292744
[TBL] [Abstract][Full Text] [Related]
39. Fast determination of anions on a short coated column.
Li J; Zhu Y; Guo Y
J Chromatogr A; 2006 Jun; 1118(1):46-50. PubMed ID: 16476438
[TBL] [Abstract][Full Text] [Related]
40. Identification of homemade inorganic explosives by ion chromatographic analysis of post-blast residues.
Johns C; Shellie RA; Potter OG; O'Reilly JW; Hutchinson JP; Guijt RM; Breadmore MC; Hilder EF; Dicinoski GW; Haddad PR
J Chromatogr A; 2008 Feb; 1182(2):205-14. PubMed ID: 18221942
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]