These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 16518245)

  • 21. A systematic review of 2-strand versus multistrand core suture techniques and functional outcome after digital flexor tendon repair.
    Hardwicke JT; Tan JJ; Foster MA; Titley OG
    J Hand Surg Am; 2014 Apr; 39(4):686-695.e2. PubMed ID: 24576754
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effects of multiple-strand suture methods on the strength and excursion of repaired intrasynovial flexor tendons: a biomechanical study in dogs.
    Winters SC; Gelberman RH; Woo SL; Chan SS; Grewal R; Seiler JG
    J Hand Surg Am; 1998 Jan; 23(1):97-104. PubMed ID: 9523962
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Intercalary flexor tendon grafts. A morphological study of intrasynovial and extrasynovial donor tendons.
    Gelberman RH; Seiler JG; Rosenberg AE; Heyman P; Amiel D
    Scand J Plast Reconstr Surg Hand Surg; 1992; 26(3):257-64. PubMed ID: 1470872
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of a new 4-strand flexor tendon repair in a cadaveric porcine model.
    Manchio JV; Shashikant MP; Shrivastava A; Weinzweig J; Vernadakis AJ
    J Hand Surg Am; 2009 Jan; 34(1):102-7. PubMed ID: 19058923
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Adhesion formation after flexor tendon repair: a histologic and biomechanical comparison of 2- and 4-strand repairs in a chicken model.
    Strick MJ; Filan SL; Hile M; McKenzie C; Walsh WR; Tonkin MA
    J Hand Surg Am; 2004 Jan; 29(1):15-21. PubMed ID: 14751097
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of the Optimal Asymmetry on the Strength of Six-Strand Tendon Repair: An Ex Vivo Biomechanical Study.
    Kozono N; Okada T; Takeuchi N; Shimoto T; Higaki H; Nakashima Y
    J Hand Surg Am; 2017 Apr; 42(4):250-256. PubMed ID: 28242243
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Suture techniques and material in surgery of flexor tendons].
    Pillukat T; Fuhrmann R; Windolf J; van Schoonhoven J
    Chirurg; 2017 Mar; 88(3):259-270. PubMed ID: 28224209
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of Flexor Tendon Repair Between 6-Strand Lim-Tsai With 4-Strand Cruciate and Becker Technique.
    Wong YR; Lee CS; Loke AM; Liu X; Suzana MJ I; Tay SC
    J Hand Surg Am; 2015 Sep; 40(9):1806-11. PubMed ID: 26142080
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair.
    Lawrence TM; Davis TR
    J Hand Surg Am; 2005 Jul; 30(4):836-41. PubMed ID: 16039381
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical testing of epitenon suture strength in Achilles tendon repairs.
    Shepard ME; Lindsey DP; Chou LB
    Foot Ankle Int; 2007 Oct; 28(10):1074-7. PubMed ID: 17923058
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The effect of a collagen-elastin matrix on adhesion formation after flexor tendon repair in a rabbit model.
    Wichelhaus DA; Beyersdoerfer ST; Gierer P; Vollmar B; Mittlmeier T
    Arch Orthop Trauma Surg; 2016 Jul; 136(7):1021-9. PubMed ID: 27161378
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biomechanical and clinical evaluation of the epitenon-first technique of flexor tendon repair.
    Papandrea R; Seitz WH; Shapiro P; Borden B
    J Hand Surg Am; 1995 Mar; 20(2):261-6. PubMed ID: 7775765
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The impact of fiberwire, fiberloop, and locking suture configuration on flexor tendon repairs.
    Haimovici L; Papafragkou S; Lee W; Dagum A; Hurst LC
    Ann Plast Surg; 2012 Oct; 69(4):468-70. PubMed ID: 22964669
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Acute flexor tendon surgery].
    Stephan C; Saalabian A; van Schoonhoven J; Prommersberger KJ
    Oper Orthop Traumatol; 2008 Mar; 20(1):44-54. PubMed ID: 18338118
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A Biomechanical Comparison Between Asymmetric Pennington Technique and Conventional Core Suture Techniques: 6-Strand Flexor Tendon Repair.
    Kozono N; Okada T; Takeuchi N; Shimoto T; Higaki H; Nakashima Y
    J Hand Surg Am; 2018 Jan; 43(1):79.e1-79.e8. PubMed ID: 28807348
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Tensile properties of suture methods for repair of partially lacerated human flexor tendon in vitro.
    Zobitz ME; Zhao C; Erhard L; Amadio PC; An KN
    J Hand Surg Am; 2001 Sep; 26(5):821-7. PubMed ID: 11561233
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Core suture purchase affects strength of tendon repairs.
    Tang JB; Zhang Y; Cao Y; Xie RG
    J Hand Surg Am; 2005 Nov; 30(6):1262-6. PubMed ID: 16344186
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Use of the Taguchi method for biomechanical comparison of flexor-tendon-repair techniques to allow immediate active flexion. A new method of analysis and optimization of technique to improve the quality of the repair.
    Singer G; Ebramzadeh E; Jones NF; Meals R
    J Bone Joint Surg Am; 1998 Oct; 80(10):1498-506. PubMed ID: 9801218
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Recent progress in flexor tendon healing.
    Silva MJ; Boyer MI; Gelberman RH
    J Orthop Sci; 2002; 7(4):508-14. PubMed ID: 12181670
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The revascularization of healing flexor tendons in the digital sheath. A vascular injection study in dogs.
    Gelberman RH; Khabie V; Cahill CJ
    J Bone Joint Surg Am; 1991 Jul; 73(6):868-81. PubMed ID: 1712787
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.