These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 16523774)

  • 21. Two-dimensional cell parameters of twisted nematic liquid crystal with an amplitude-sensitive heterodyne ellipsometer.
    Wei HC; Tsai CC; Yu LP; Lin TE; Yu CJ; Liu MH; Chou C
    Appl Opt; 2009 Mar; 48(9):1628-34. PubMed ID: 19305458
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Compact spatial polariscope for light polarization state analysis.
    Woźniak WA; Kurzynowski P
    Opt Express; 2008 Jul; 16(14):10471-9. PubMed ID: 18607460
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Stokes Parameter Detection and Precision Analysis Based on Rotating Quarter-Wave Plate].
    Zhi DD; Li JJ; Gao DY; Yuan YL; Zhai WC; Pang WW; Zheng XB
    Guang Pu Xue Yu Guang Pu Fen Xi; 2016 Aug; 36(8):2655-9. PubMed ID: 30074724
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Achromatic athermalized retarder fabrication.
    Mahler AB; McClain S; Chipman R
    Appl Opt; 2011 Feb; 50(5):755-65. PubMed ID: 21343998
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Small-angle measurement with highly sensitive total-internal-reflection heterodyne interferometer.
    Lin JY; Liao YC
    Appl Opt; 2014 Mar; 53(9):1903-8. PubMed ID: 24663469
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Laser heterodyne interferometer with rotational error compensation for precision displacement measurement.
    Zhang E; Chen B; Zheng H; Yan L; Teng X
    Opt Express; 2018 Jan; 26(1):90-98. PubMed ID: 29328296
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Characterization on five effective parameters of anisotropic optical material using Stokes parameters-Demonstration by a fiber-type polarimeter.
    Lo YL; Pham TT; Chen PC
    Opt Express; 2010 Apr; 18(9):9133-50. PubMed ID: 20588761
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Optical heterodyne polarimeter for measuring the chiral parameter and the circular refraction indices of optical activity.
    King HJ; Chou C; Lu ST
    Opt Lett; 1993 Nov; 18(22):1970-2. PubMed ID: 19829464
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Application of phase-to-amplitude conversion technique to linear birefringence measurements.
    Teng HK; Chou C; Chang CN; Wu HT
    Appl Opt; 2003 Apr; 42(10):1798-804. PubMed ID: 12683758
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Dynamic polarization states and birefringence distributions measurements in spatial elliptical polariscope using Fourier analysis method.
    Kurzynowski P; Drobczynski S; Woźniak WA
    Opt Express; 2009 Jun; 17(12):10144-54. PubMed ID: 19506668
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Optimization of system parameters for a complete multispectral polarimeter.
    Hollstein A; Ruhtz T; Fischer J; Preusker R
    Appl Opt; 2009 Aug; 48(24):4767-73. PubMed ID: 19696867
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Full-field retardation measurement of a liquid crystal cell with a phase shift polariscope.
    Pin W; Asundi A
    Appl Opt; 2008 Aug; 47(24):4391-5. PubMed ID: 18716644
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Angstrom-range optical path-length measurement with a high-speed scanning heterodyne optical interferometer.
    Riza NA; Arain MA
    Appl Opt; 2003 May; 42(13):2341-5. PubMed ID: 12737467
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Dual-frequency heterodyne ellipsometer for characterizing generalized elliptically birefringent media.
    Yu CJ; Lin CE; Li YC; Chou LD; Wu JS; Lee CC; Chou C
    Opt Express; 2009 Oct; 17(21):19213-24. PubMed ID: 20372658
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Optical feedback laser with a quartz crystal plate in the external cavity.
    Liu G; Zhang S; Zhu J; Li Y
    Appl Opt; 2003 Nov; 42(33):6636-9. PubMed ID: 14658465
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Measurement method of Stokes parameters using a quarter-wave plate with phase difference errors.
    Kihara T
    Appl Opt; 2011 Jun; 50(17):2582-7. PubMed ID: 21673759
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Decoupling refractive index and geometric thickness from interferometric measurements of a quartz sample using a fourth-order polynomial.
    Ince R; Hüseyinoglu E
    Appl Opt; 2007 Jun; 46(17):3498-503. PubMed ID: 17514309
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Calibration method using a single retarder to simultaneously measure polarization and fully characterize a polarimeter over a broad range of wavelengths.
    Romerein MJ; Philippson JN; Brooks RL; Shiell RC
    Appl Opt; 2011 Oct; 50(28):5382-9. PubMed ID: 22016204
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Validation of separated source frequency delivery for a fiber-coupled heterodyne displacement interferometer.
    Meskers AJ; Spronck JW; Munnig Schmidt RH
    Opt Lett; 2014 Aug; 39(15):4603-6. PubMed ID: 25078239
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Heterodyne interferometer with two parallel-polarized input beams for high-resolution roll angle measurement.
    Qi J; Wang Z; Huang J; Wang Q; Gao J
    Opt Express; 2019 May; 27(10):13820-13830. PubMed ID: 31163841
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.