BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 16532955)

  • 1. Development and evaluation of an exact fan-beam reconstruction algorithm using an equal weighting scheme via locally compensated filtered backprojection (LCFBP).
    Chen GH; Tokalkanahalli R; Zhuang T; Nett BE; Hsieh J
    Med Phys; 2006 Feb; 33(2):475-81. PubMed ID: 16532955
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector.
    Leng S; Zhuang T; Nett BE; Chen GH
    Phys Med Biol; 2005 Apr; 50(8):1805-20. PubMed ID: 15815097
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A shift-invariant filtered backprojection (FBP) cone-beam reconstruction algorithm for the source trajectory of two concentric circles using an equal weighting scheme.
    Zhuang T; Nett BE; Leng S; Chen GH
    Phys Med Biol; 2006 Jun; 51(12):3189-210. PubMed ID: 16757871
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data.
    Zhuang T; Leng S; Nett BE; Chen GH
    Phys Med Biol; 2004 Dec; 49(24):5489-503. PubMed ID: 15724538
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fan-beam filtered-backprojection reconstruction without backprojection weight.
    Dennerlein F; Noo F; Hornegger J; Lauritsch G
    Phys Med Biol; 2007 Jun; 52(11):3227-40. PubMed ID: 17505099
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Backprojection-filtration reconstruction without invoking a spatially varying weighting factor.
    Xia D; Cho S; Pan X
    Med Phys; 2010 Mar; 37(3):1201-9. PubMed ID: 20384257
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Spatial resolution improvement and dose reduction potential for inner ear CT imaging using a z-axis deconvolution technique.
    McCollough CH; Leng S; Sunnegardh J; Vrieze TJ; Yu L; Lane J; Raupach R; Stierstorfer K; Flohr T
    Med Phys; 2013 Jun; 40(6):061904. PubMed ID: 23718595
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A filtered backprojection algorithm for cone beam reconstruction using rotational filtering under helical source trajectory.
    Tang X; Hsieh J
    Med Phys; 2004 Nov; 31(11):2949-60. PubMed ID: 15587646
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.
    Tang X; Hsieh J; Nilsen RA; Dutta S; Samsonov D; Hagiwara A
    Phys Med Biol; 2006 Feb; 51(4):855-74. PubMed ID: 16467583
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Region-of-interest reconstruction of motion-contaminated data using a weighted backprojection filtration algorithm.
    King M; Pan X; Yu L; Giger M
    Med Phys; 2006 May; 33(5):1222-38. PubMed ID: 16752557
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hilbert transform based FBP algorithm for fan-beam CT full and partial scans.
    You J; Zeng GL
    IEEE Trans Med Imaging; 2007 Feb; 26(2):190-9. PubMed ID: 17304733
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A local region of interest image reconstruction via filtered backprojection for fan-beam differential phase-contrast computed tomography.
    Qi Z; Chen GH
    Phys Med Biol; 2007 Sep; 52(18):N417-23. PubMed ID: 17804875
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An alternative solution to the nonuniform noise propagation problem in fan-beam FBP image reconstruction.
    Wang J; Lu H; Li T; Liang Z
    Med Phys; 2005 Nov; 32(11):3389-94. PubMed ID: 16372414
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Axial Cone-Beam Reconstruction by Weighted BPF/DBPF and Orthogonal Butterfly Filtering.
    Tang S; Tang X
    IEEE Trans Biomed Eng; 2016 Sep; 63(9):1895-1903. PubMed ID: 26660512
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Image reconstruction in peripheral and central regions-of-interest and data redundancy.
    Pan X; Zou Y; Xia D
    Med Phys; 2005 Mar; 32(3):673-84. PubMed ID: 15839339
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT.
    Zou Y; Pan X
    Phys Med Biol; 2004 Jun; 49(12):2717-31. PubMed ID: 15272684
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A rebinned backprojection-filtration algorithm for image reconstruction in helical cone-beam CT.
    Yu L; Xia D; Zou Y; Sidky EY; Bian J; Pan X
    Phys Med Biol; 2007 Sep; 52(18):5497-508. PubMed ID: 17804878
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of z-axis resolution and image noise for nonconstant velocity spiral CT data reconstructed using a weighted 3D filtered backprojection (WFBP) reconstruction algorithm.
    Christner JA; Stierstorfer K; Primak AN; Eusemann CD; Flohr TG; McCollough CH
    Med Phys; 2010 Feb; 37(2):897-906. PubMed ID: 20229899
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel extension of the parallel-beam projection-slice theorem to divergent fan-beam and cone-beam projections.
    Chen GH; Leng S; Mistretta CA
    Med Phys; 2005 Mar; 32(3):654-65. PubMed ID: 15839337
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new framework of image reconstruction from fan beam projections.
    Chen GH
    Med Phys; 2003 Jun; 30(6):1151-61. PubMed ID: 12852540
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.