These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 16536431)

  • 1. Stable sensors with tunable sensitivities based on class II xerogels.
    Tao Z; Tehan EC; Tang Y; Bright FV
    Anal Chem; 2006 Mar; 78(6):1939-45. PubMed ID: 16536431
    [TBL] [Abstract][Full Text] [Related]  

  • 2. O(2)-responsive chemical sensors based on hybrid xerogels that contain fluorinated precursors.
    Bukowski RM; Davenport MD; Titus AH; Bright FV
    Appl Spectrosc; 2006 Sep; 60(9):951-7. PubMed ID: 17002817
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tailored xerogel-based sensor arrays and artificial neural networks yield improved O2 detection accuracy and precision.
    Tang Y; Tao Z; Bukowski RM; Tehan EC; Karri S; Titus AH; Bright FV
    Analyst; 2006 Oct; 131(10):1129-36. PubMed ID: 17003861
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Structurally integrated organic light emitting device-based sensors for gas phase and dissolved oxygen.
    Shinar R; Zhou Z; Choudhury B; Shinar J
    Anal Chim Acta; 2006 May; 568(1-2):190-9. PubMed ID: 17761260
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Templated xerogels as platforms for biomolecule-less biomolecule sensors.
    Tao Z; Tehan EC; Bukowski RM; Tang Y; Shughart EL; Holthoff WG; Cartwright AN; Titus AH; Bright FV
    Anal Chim Acta; 2006 Mar; 564(1):59-65. PubMed ID: 17723362
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sensitivity-Enhanced CMOS Phase Luminometry System Using Xerogel-Based Sensors.
    Lei Yao ; Khan R; Chodavarapu VP; Tripathi VS; Bright FV
    IEEE Trans Biomed Circuits Syst; 2009 Oct; 3(5):304-11. PubMed ID: 23853269
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-performance quenchometric oxygen sensors based on fluorinated xerogels doped with [Ru(dpp)3]2+.
    Bukowski RM; Ciriminna R; Pagliaro M; Bright FV
    Anal Chem; 2005 Apr; 77(8):2670-2. PubMed ID: 15828809
    [TBL] [Abstract][Full Text] [Related]  

  • 8. CMOS Imaging of Temperature Effects on Pin-Printed Xerogel Sensor Microarrays.
    Lei Yao ; Ka Yi Yung ; Chodavarapu VP; Bright FV
    IEEE Trans Biomed Circuits Syst; 2011 Apr; 5(2):189-96. PubMed ID: 23851206
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Novel hybrid optical sensor materials for in-breath O(2) analysis.
    Higgins C; Wencel D; Burke CS; MacCraith BD; McDonagh C
    Analyst; 2008 Feb; 133(2):241-7. PubMed ID: 18227948
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sol-gel derived nitric oxide-releasing oxygen sensors.
    Marxer SM; Robbins ME; Schoenfisch MH
    Analyst; 2005 Feb; 130(2):206-12. PubMed ID: 15665975
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radioluminescent light source for the development of optical sensor arrays.
    Holthoff WG; Tehan EC; Bukowski RM; Kent N; Maccraith BD; Bright FV
    Anal Chem; 2005 Jan; 77(2):718-23. PubMed ID: 15649078
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sol-gel-derived sensor materials that yield linear calibration plots, high sensitivity, and long-term stability.
    Tang Y; Tehan EC; Tao Z; Bright FV
    Anal Chem; 2003 May; 75(10):2407-13. PubMed ID: 12918984
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Photoluminiscence response of Ru(II) complex immobilized in SiO2-based matrix to dissolved oxygen in beer.
    Anastasova S; Milanova M; Todorovsky D
    J Biochem Biophys Methods; 2008 Apr; 70(6):1292-6. PubMed ID: 17976732
    [TBL] [Abstract][Full Text] [Related]  

  • 14. CMOS Imaging of Pin-Printed Xerogel-Based Luminescent Sensor Microarrays.
    Yao L; Yung KY; Khan R; Chodavarapu VP; Bright FV
    IEEE Sens J; 2010 Dec; 10(12):1824-1832. PubMed ID: 24489484
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Inkjet printed LED based pH chemical sensor for gas sensing.
    O'Toole M; Shepherd R; Wallace GG; Diamond D
    Anal Chim Acta; 2009 Oct; 652(1-2):308-14. PubMed ID: 19786197
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tris(2,2'-bipyridyl)ruthenium(II) electrochemiluminescence sensor based on carbon nanotube/organically modified silicate films.
    Tao Y; Lin ZJ; Chen XM; Chen X; Wang XR
    Anal Chim Acta; 2007 Jul; 594(2):169-74. PubMed ID: 17586111
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fabrication and performance evaluation of highly sensitive hybrid sol-gel-derived oxygen sensor films based on a fluorinated precursor.
    Estella J; Wencel D; Moore JP; Sourdaine M; McDonagh C
    Anal Chim Acta; 2010 May; 666(1-2):83-90. PubMed ID: 20433969
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of spatiotemporal response information from sorption-based sensor arrays to identify and quantify the composition of analyte mixtures.
    Woodka MD; Brunschwig BS; Lewis NS
    Langmuir; 2007 Dec; 23(26):13232-41. PubMed ID: 18001074
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contact CMOS imaging of gaseous oxygen sensor array.
    Daivasagaya DS; Yao L; Yi Yung K; Hajj-Hassan M; Cheung MC; Chodavarapu VP; Bright FV
    Sens Actuators B Chem; 2011 Oct; 157(2):408-16. PubMed ID: 24493909
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Site selectively templated and tagged xerogels for chemical sensors.
    Shughart EL; Ahsan K; Detty MR; Bright FV
    Anal Chem; 2006 May; 78(9):3165-70. PubMed ID: 16643009
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.