279 related articles for article (PubMed ID: 16537176)
1. An amperometric enzyme electrode for creatine determination prepared by the immobilization of creatinase and sarcosine oxidase in poly(vinylferrocenium).
Erden PE; Pekyardimci S; Kiliç E; Arslan F
Artif Cells Blood Substit Immobil Biotechnol; 2006; 34(2):223-39. PubMed ID: 16537176
[TBL] [Abstract][Full Text] [Related]
2. Determination of creatine in commercial creatine powder with new potentiometric and amperometric biosensors.
Karakuş E; Erden PE; Pekyardimci S; Kiliç E
Artif Cells Blood Substit Immobil Biotechnol; 2006; 34(3):337-47. PubMed ID: 16809134
[TBL] [Abstract][Full Text] [Related]
3. Glucose biosensor based on the immobilization of glucose oxidase on electrochemically synthesized polypyrrole-poly(vinyl sulphonate) composite film by cross-linking with glutaraldehyde.
Colak O; Yaşar A; Cete S; Arslan F
Artif Cells Blood Substit Immobil Biotechnol; 2012 Oct; 40(5):354-61. PubMed ID: 22540929
[TBL] [Abstract][Full Text] [Related]
4. Immobilization of creatininase, creatinase and sarcosine oxidase on iron oxide nanoparticles/chitosan-g-polyaniline modified Pt electrode for detection of creatinine.
Yadav S; Devi R; Bhar P; Singhla S; Pundir CS
Enzyme Microb Technol; 2012 Apr; 50(4-5):247-54. PubMed ID: 22418265
[TBL] [Abstract][Full Text] [Related]
5. An Fe3O4-nanoparticles-based amperometric biosensor for creatine determination.
Kaçar C; Erden PE; Pekyardimci S; Kiliç E
Artif Cells Nanomed Biotechnol; 2013 Feb; 41(1):2-7. PubMed ID: 22889270
[TBL] [Abstract][Full Text] [Related]
6. Polyvinylferrocenium modified Pt electrode for the design of amperometric choline and acetylcholine enzyme electrodes.
Sen S; Gülce A; Gülce H
Biosens Bioelectron; 2004 May; 19(10):1261-8. PubMed ID: 15046758
[TBL] [Abstract][Full Text] [Related]
7. Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and aniline in sulphuric Acid for the determination of cholesterol in serum.
Muhammet SM; Cete S; Arslan F; Yaşar A
Artif Cells Blood Substit Immobil Biotechnol; 2009; 37(6):273-8. PubMed ID: 19922167
[TBL] [Abstract][Full Text] [Related]
8. An amperometric biosensor for L-glutamate determination prepared from L-glutamate oxidase immobilized in polypyrrole-polyvinylsulphonate film.
Şimşek Ş; Aynacı E; Arslan F
Artif Cells Nanomed Biotechnol; 2016; 44(1):356-61. PubMed ID: 25682838
[TBL] [Abstract][Full Text] [Related]
9. Simultaneous detection of creatine and creatinine using a sequential injection analysis/biosensor system.
Stefan-van Staden RI; Bokretsion RG; van Staden JF; Aboul-Enein HY
Prep Biochem Biotechnol; 2006; 36(4):287-96. PubMed ID: 16971300
[TBL] [Abstract][Full Text] [Related]
10. Development of a conductometric phosphate biosensor based on tri-layer maltose phosphorylase composite films.
Zhang Z; Jaffrezic-Renault N; Bessueille F; Leonard D; Xia S; Wang X; Chen L; Zhao J
Anal Chim Acta; 2008 May; 615(1):73-9. PubMed ID: 18440365
[TBL] [Abstract][Full Text] [Related]
11. Preparation of a polypyrrole-polyvinylsulphonate composite film biosensor for determination of phenol based on entrapment of polyphenol oxidase.
Arslan H; Arslan F
Artif Cells Blood Substit Immobil Biotechnol; 2011 Oct; 39(5):341-5. PubMed ID: 21899484
[TBL] [Abstract][Full Text] [Related]
12. Polyvinylferrocenium modified Pt electrode for anaerobic glucose monitoring.
Gülce A; Gülce H
J Biochem Biophys Methods; 2005 Jan; 62(1):81-92. PubMed ID: 15656946
[TBL] [Abstract][Full Text] [Related]
13. Amperometric biosensor for the determination of creatine.
Ramanavicius A
Anal Bioanal Chem; 2007 Mar; 387(5):1899-906. PubMed ID: 17221239
[TBL] [Abstract][Full Text] [Related]
14. Development and optimization of a novel conductometric bi-enzyme biosensor for L-arginine determination.
Saiapina OY; Dzyadevych SV; Jaffrezic-Renault N; Soldatkin OP
Talanta; 2012 Apr; 92():58-64. PubMed ID: 22385808
[TBL] [Abstract][Full Text] [Related]
15. Choline-sensing carbon paste electrode containing polyaniline (pani)-silicon dioxide composite-modified choline oxidase.
Özdemir M; Arslan H
Artif Cells Nanomed Biotechnol; 2014 Feb; 42(1):27-31. PubMed ID: 23432401
[TBL] [Abstract][Full Text] [Related]
16. An improved amperometric creatinine biosensor based on nanoparticles of creatininase, creatinase and sarcosine oxidase.
Kumar P; Jaiwal R; Pundir CS
Anal Biochem; 2017 Nov; 537():41-49. PubMed ID: 28870830
[TBL] [Abstract][Full Text] [Related]
17. A new amperometric enzyme electrode for alcohol determination.
Gülce H; Gülce A; Kavanoz M; Coşkun H; Yildiz A
Biosens Bioelectron; 2002 Jun; 17(6-7):517-21. PubMed ID: 11959473
[TBL] [Abstract][Full Text] [Related]
18. Biocompatible glucose sensor prepared by modifying protein and vinylferrocene monomer composite membrane.
Kurita R; Tabei H; Iwasaki Y; Hayashi K; Sunagawa K; Niwa O
Biosens Bioelectron; 2004 Oct; 20(3):518-23. PubMed ID: 15494234
[TBL] [Abstract][Full Text] [Related]
19. A stable three-enzyme creatinine biosensor. 1. Impact of structure, function and environment on PEGylated and immobilized sarcosine oxidase.
Berberich JA; Yang LW; Madura J; Bahar I; Russell AJ
Acta Biomater; 2005 Mar; 1(2):173-81. PubMed ID: 16701794
[TBL] [Abstract][Full Text] [Related]
20. Development of cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on oxygen electrode for the determination of total cholesterol in food samples.
Basu AK; Chattopadhyay P; Roychoudhuri U; Chakraborty R
Bioelectrochemistry; 2007 May; 70(2):375-9. PubMed ID: 16814618
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]