  • 21. Electrochemical detection of cardiac troponin I using a microchip with the surface-functionalized poly(dimethylsiloxane) channel.
    Ko S; Kim B; Jo SS; Oh SY; Park JK
    Biosens Bioelectron; 2007 Aug; 23(1):51-9. PubMed ID: 17462876
    [TBL] [Abstract][Full Text] [Related]  

  • 22. "Macromolecules to PDMS transfer" as a general route for PDMS biochips.
    Heyries KA; Mandon CA; Ceriotti L; Ponti J; Colpo P; Blum LJ; Marquette CA
    Biosens Bioelectron; 2009 Jan; 24(5):1146-52. PubMed ID: 18676139
    [TBL] [Abstract][Full Text] [Related]  

  • 23. High performance protein microarrays based on glycidyl methacrylate-modified polyethylene terephthalate plastic substrate.
    Liu Y; Li CM; Hu W; Lu Z
    Talanta; 2009 Jan; 77(3):1165-71. PubMed ID: 19064107
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Microfluidic systems integrated with two-dimensional surface plasmon resonance phase imaging systems for microarray immunoassay.
    Lee KH; Su YD; Chen SJ; Tseng FG; Lee GB
    Biosens Bioelectron; 2007 Nov; 23(4):466-72. PubMed ID: 17618110
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Cross-talk problem on a fluorescence multi-channel microfluidic chip system.
    Irawan R; Tjin SC; Yager P; Zhang D
    Biomed Microdevices; 2005 Sep; 7(3):205-11. PubMed ID: 16133808
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Rapid and simple immunosensing system for simultaneous detection of tumor markers based on negative-dielectrophoretic manipulation of microparticles.
    Lee HJ; Lee SH; Yasukawa T; Ramón-Azcón J; Mizutani F; Ino K; Shiku H; Matsue T
    Talanta; 2010 Apr; 81(1-2):657-63. PubMed ID: 20188978
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Protein pattern transfer for biosensor applications.
    Volcke C; Gandhiraman RP; Basabe-Desmonts L; Iacono M; Gubala V; Cecchet F; Cafolla AA; Williams DE
    Biosens Bioelectron; 2010 Feb; 25(6):1295-300. PubMed ID: 19900799
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Microfluidic immunosensor systems.
    Bange A; Halsall HB; Heineman WR
    Biosens Bioelectron; 2005 Jun; 20(12):2488-503. PubMed ID: 15854821
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A 3D porous polymer monolith-based platform integrated in poly(dimethylsiloxane) microchips for immunoassay.
    Kang QS; Shen XF; Hu NN; Hu MJ; Liao H; Wang HZ; He ZK; Huang WH
    Analyst; 2013 May; 138(9):2613-9. PubMed ID: 23478568
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Fabrication and characteristics of MOSFET protein chip for detection of ribosomal protein.
    Park KY; Kim MS; Choi SY
    Biosens Bioelectron; 2005 Apr; 20(10):2111-5. PubMed ID: 15741082
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Silicon chip-based patch-clamp electrodes integrated with PDMS microfluidics.
    Pantoja R; Nagarah JM; Starace DM; Melosh NA; Blunck R; Bezanilla F; Heath JR
    Biosens Bioelectron; 2004 Oct; 20(3):509-17. PubMed ID: 15494233
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Bead-based immunoassays using a micro-chip flow cytometer.
    Holmes D; She JK; Roach PL; Morgan H
    Lab Chip; 2007 Aug; 7(8):1048-56. PubMed ID: 17653348
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A hybrid poly(dimethylsiloxane) microsystem for on-chip whole blood filtration optimized for steroid screening.
    Thorslund S; Klett O; Nikolajeff F; Markides K; Bergquist J
    Biomed Microdevices; 2006 Mar; 8(1):73-9. PubMed ID: 16491334
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Microfluidic device for immunoassays based on surface plasmon resonance imaging.
    Luo Y; Yu F; Zare RN
    Lab Chip; 2008 May; 8(5):694-700. PubMed ID: 18432338
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Integrated thin-film polymer/fullerene photodetectors for on-chip microfluidic chemiluminescence detection.
    Wang X; Hofmann O; Das R; Barrett EM; deMello AJ; deMello JC; Bradley DD
    Lab Chip; 2007 Jan; 7(1):58-63. PubMed ID: 17180205
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Peptide microarrays for serum antibody diagnostics.
    Andresen H; Bier FF
    Methods Mol Biol; 2009; 509():123-34. PubMed ID: 19212718
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Functionalized 3D-hydrogel plugs covalently patterned inside hydrophilic poly(dimethylsiloxane) microchannels for flow-through immunoassays.
    Sung WC; Chen HH; Makamba H; Chen SH
    Anal Chem; 2009 Oct; 81(19):7967-73. PubMed ID: 19722534
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Surface modification of glycidyl-containing poly(methyl methacrylate) microchips using surface-initiated atom-transfer radical polymerization.
    Sun X; Liu J; Lee ML
    Anal Chem; 2008 Feb; 80(3):856-63. PubMed ID: 18179249
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Modeling and optimization of high-sensitivity, low-volume microfluidic-based surface immunoassays.
    Zimmermann M; Delamarche E; Wolf M; Hunziker P
    Biomed Microdevices; 2005 Jun; 7(2):99-110. PubMed ID: 15940422
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Patterning microbeads inside poly(dimethylsiloxane) microfluidic channels and its application for immobilized microfluidic enzyme reactors.
    Zhang Q; Xu JJ; Chen HY
    Electrophoresis; 2006 Dec; 27(24):4943-51. PubMed ID: 17117456
    [TBL] [Abstract][Full Text] [Related]  