These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

305 related articles for article (PubMed ID: 16555085)

  • 21. Detection of local lung air content by electrical impedance tomography compared with electron beam CT.
    Frerichs I; Hinz J; Herrmann P; Weisser G; Hahn G; Dudykevych T; Quintel M; Hellige G
    J Appl Physiol (1985); 2002 Aug; 93(2):660-6. PubMed ID: 12133877
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Positive end-expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery.
    Erlandsson K; Odenstedt H; Lundin S; Stenqvist O
    Acta Anaesthesiol Scand; 2006 Aug; 50(7):833-9. PubMed ID: 16879466
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effects of individualized electrical impedance tomography and image reconstruction settings upon the assessment of regional ventilation distribution: Comparison to 4-dimensional computed tomography in a porcine model.
    Thürk F; Boehme S; Mudrak D; Kampusch S; Wielandner A; Prosch H; Braun C; Toemboel FPR; Hofmanninger J; Kaniusas E
    PLoS One; 2017; 12(8):e0182215. PubMed ID: 28763474
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Electric impedance tomography and protective mechanical ventilation in elective robotic-assisted laparoscopy surgery with steep Trendelenburg position: a randomized controlled study.
    Buonanno P; Marra A; Iacovazzo C; Merola R; De Siena AU; Servillo G; Vargas M
    Sci Rep; 2023 Feb; 13(1):2753. PubMed ID: 36797394
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Specifics of anesthesiology in the operative phase of laparoscopic surgery].
    Weyland W; Crozier TA; Bräuer A; Georgius P; Weyland A; Neufang T; Braun U
    Zentralbl Chir; 1993; 118(10):582-7. PubMed ID: 8259726
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Electrical Impedance Tomography for Cardio-Pulmonary Monitoring.
    Putensen C; Hentze B; Muenster S; Muders T
    J Clin Med; 2019 Aug; 8(8):. PubMed ID: 31394721
    [TBL] [Abstract][Full Text] [Related]  

  • 27. What hinders pulmonary gas exchange and changes distribution of ventilation in immobilized white rhinoceroses (
    Mosing M; Waldmann AD; Sacks M; Buss P; Boesch JM; Zeiler GE; Hosgood G; Gleed RD; Miller M; Meyer LCR; Böhm SH
    J Appl Physiol (1985); 2020 Nov; 129(5):1140-1149. PubMed ID: 33054661
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effects of restricted thoracic movement on the regional distribution of ventilation.
    Pulletz S; Elke G; Zick G; Schädler D; Reifferscheid F; Weiler N; Frerichs I
    Acta Anaesthesiol Scand; 2010 Jul; 54(6):751-60. PubMed ID: 20397981
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome assessed by electric impedance tomography.
    Lowhagen K; Lundin S; Stenqvist O
    Minerva Anestesiol; 2010 Dec; 76(12):1024-35. PubMed ID: 21178912
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Assessment of Ventilation Distribution during Laparoscopic Bariatric Surgery: An Electrical Impedance Tomography Study.
    Stankiewicz-Rudnicki M; Gaszynski W; Gaszynski T
    Biomed Res Int; 2016; 2016():7423162. PubMed ID: 28058262
    [No Abstract]   [Full Text] [Related]  

  • 31. A comparison of different bedside techniques to determine endotracheal tube position in a neonatal piglet model.
    Schmölzer GM; Bhatia R; Davis PG; Tingay DG
    Pediatr Pulmonol; 2013 Feb; 48(2):138-45. PubMed ID: 22615185
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Impact of PEEP during laparoscopic surgery on early postoperative ventilation distribution visualized by electrical impedance tomography.
    Karsten J; Heinze H; Meier T
    Minerva Anestesiol; 2014 Feb; 80(2):158-66. PubMed ID: 23877309
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Noninvasive, simultaneous, and continuous measurements of stroke volume and tidal volume using EIT: feasibility study of animal experiments.
    Jang GY; Jeong YJ; Zhang T; Oh TI; Ko RE; Chung CR; Suh GY; Woo EJ
    Sci Rep; 2020 Jul; 10(1):11242. PubMed ID: 32647206
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Assessing effects of PEEP and global expiratory lung volume on regional electrical impedance tomography.
    Markhorst DG; Groeneveld AB; Heethaar RM; Zonneveld E; Van Genderingen HR
    J Med Eng Technol; 2009; 33(4):281-7. PubMed ID: 19384703
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Protective ventilation using electrical impedance tomography.
    Luepschen H; Meier T; Grossherr M; Leibecke T; Karsten J; Leonhardt S
    Physiol Meas; 2007 Jul; 28(7):S247-60. PubMed ID: 17664639
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Unilateral empyema impacts the assessment of regional lung ventilation by electrical impedance tomography.
    Bläser D; Pulletz S; Becher T; Schädler D; Elke G; Weiler N; Frerichs I
    Physiol Meas; 2014 Jun; 35(6):975-83. PubMed ID: 24844247
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Monitoring changes in lung air and liquid volumes with electrical impedance tomography.
    Adler A; Amyot R; Guardo R; Bates JH; Berthiaume Y
    J Appl Physiol (1985); 1997 Nov; 83(5):1762-7. PubMed ID: 9375349
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Coupling of EIT with computational lung modeling for predicting patient-specific ventilatory responses.
    Roth CJ; Becher T; Frerichs I; Weiler N; Wall WA
    J Appl Physiol (1985); 2017 Apr; 122(4):855-867. PubMed ID: 27932671
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Variety of non-invasive continuous monitoring methodologies including electrical impedance tomography provides novel insights into the physiology of lung collapse and recruitment – case report of an anaesthetized horse.
    Moens Y; Schramel JP; Tusman G; Ambrisko TD; Solà J; Brunner JX; Kowalczyk L; Böhm SH
    Vet Anaesth Analg; 2014 Mar; 41(2):196-204. PubMed ID: 24734295
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Electrical impedance tomography applied to assess matching of pulmonary ventilation and perfusion in a porcine experimental model.
    Fagerberg A; Stenqvist O; Aneman A
    Crit Care; 2009; 13(2):R34. PubMed ID: 19265527
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.