These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 16556302)

  • 1. Reconstruction of skeletal movement using skin markers: comparative assessment of bone pose estimators.
    Cereatti A; Della Croce U; Cappozzo A
    J Neuroeng Rehabil; 2006 Mar; 3():7. PubMed ID: 16556302
    [TBL] [Abstract][Full Text] [Related]  

  • 2. What portion of the soft tissue artefact requires compensation when estimating joint kinematics?
    Dumas R; Camomilla V; Bonci T; Chèze L; Cappozzo A
    J Biomech Eng; 2015 Jun; 137(6):064502. PubMed ID: 25867934
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A model of the soft tissue artefact rigid component.
    Camomilla V; Bonci T; Dumas R; Chèze L; Cappozzo A
    J Biomech; 2015 Jul; 48(10):1752-9. PubMed ID: 26091618
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative assessment of knee joint models used in multi-body kinematics optimisation for soft tissue artefact compensation.
    Richard V; Cappozzo A; Dumas R
    J Biomech; 2017 Sep; 62():95-101. PubMed ID: 28237187
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative assessment of bone pose estimation using Point Cluster Technique and OpenSim.
    Lathrop RL; Chaudhari AM; Siston RA
    J Biomech Eng; 2011 Nov; 133(11):114503. PubMed ID: 22168744
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Femoral Clamp to Reduce Soft Tissue Artifact: Accuracy and Reliability in Measuring Three-Dimensional Knee Kinematics During Gait.
    Ding Z; Güdel M; Smith SHL; Ademefun RA; Bull AMJ
    J Biomech Eng; 2020 Apr; 142(4):. PubMed ID: 31596924
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In situ comparison of A-mode ultrasound tracking system and skin-mounted markers for measuring kinematics of the lower extremity.
    Niu K; Anijs T; Sluiter V; Homminga J; Sprengers A; Marra MA; Verdonschot N
    J Biomech; 2018 Apr; 72():134-143. PubMed ID: 29573792
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity.
    Akbarshahi M; Schache AG; Fernandez JW; Baker R; Banks S; Pandy MG
    J Biomech; 2010 May; 43(7):1292-301. PubMed ID: 20206357
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of the lower limb soft tissue artefact at marker-cluster level with a high-density marker set during walking.
    Barré A; Aissaoui R; Aminian K; Dumas R
    J Biomech; 2017 Sep; 62():21-26. PubMed ID: 28577907
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A simulation study to investigate an extension to the point cluster technique.
    Karmarkar V; Vitali RV
    Sci Rep; 2023 Nov; 13(1):19941. PubMed ID: 37968498
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics.
    Lucchetti L; Cappozzo A; Cappello A; Della Croce U
    J Biomech; 1998 Nov; 31(11):977-84. PubMed ID: 9880054
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Main component of soft tissue artifact of the upper-limbs with respect to different functional, daily life and sports movements.
    Blache Y; Dumas R; Lundberg A; Begon M
    J Biomech; 2017 Sep; 62():39-46. PubMed ID: 27793408
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A soft tissue artefact model driven by proximal and distal joint kinematics.
    Bonci T; Camomilla V; Dumas R; Chèze L; Cappozzo A
    J Biomech; 2014 Jul; 47(10):2354-61. PubMed ID: 24818796
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparing the accuracy of open-source pose estimation methods for measuring gait kinematics.
    Washabaugh EP; Shanmugam TA; Ranganathan R; Krishnan C
    Gait Posture; 2022 Sep; 97():188-195. PubMed ID: 35988434
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of soft tissue artifacts on the calculated kinematics of the knee during walking and running.
    Wang W; Li X; Zhang T; Li J; Viellehner J; Komnik I; Wang S; Potthast W
    J Biomech; 2023 Mar; 150():111474. PubMed ID: 36871431
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A joint kinematics driven model of the pelvic soft tissue artefact.
    Camomilla V; Bonci T
    J Biomech; 2020 Oct; 111():109998. PubMed ID: 32891015
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Kinetics influence of multibody kinematics optimisation for soft tissue artefact compensation.
    Pomarat Z; Guitteny S; Dumas R; Muller A
    J Biomech; 2023 Mar; 150():111514. PubMed ID: 36867951
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Do kinematic models reduce the effects of soft tissue artefacts in skin marker-based motion analysis? An in vivo study of knee kinematics.
    Andersen MS; Benoit DL; Damsgaard M; Ramsey DK; Rasmussen J
    J Biomech; 2010 Jan; 43(2):268-73. PubMed ID: 19879581
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of the soft tissue artifact on marker measurements and on the calculation of the helical axis of the knee during a gait cycle: A study on the CAMS-Knee data set.
    Ancillao A; Aertbeliën E; De Schutter J
    Hum Mov Sci; 2021 Dec; 80():102866. PubMed ID: 34509901
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of soft tissue artefacts on computed segmental and stifle kinematics in canine motion analysis.
    Lu M; Lin CC; Lu TW; Wang SN; Wu CH
    Vet Rec; 2020 Jan; 186(2):66. PubMed ID: 31409754
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.