These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
102 related articles for article (PubMed ID: 16556687)
1. Improved specificity of a new homogeneous assay for LDL-cholesterol in serum with abnormal lipoproteins. Iwasaki Y; Matsuyama H; Nakashima N Clin Chem; 2006 May; 52(5):886-8. PubMed ID: 16556687 [TBL] [Abstract][Full Text] [Related]
2. [Multicenter evaluation of four homogenous LDL-cholesterol assays]. Bayer P; Veinberg F; Couderc R; Cherfils C; Cambillau M; Cosson C; Fradin S; Gillery P; Steinmetz J; Legrand A; Egloff M; Beucler I Ann Biol Clin (Paris); 2005; 63(1):27-41. PubMed ID: 15689310 [TBL] [Abstract][Full Text] [Related]
3. Evaluation of two different homogeneous assays for LDL-cholesterol in lipoprotein-X-positive serum. Fei H; Maeda S; Kirii H; Fujigaki S; Maekawa N; Fujii H; Wada H; Saito K; Seishima M Clin Chem; 2000 Sep; 46(9):1351-6. PubMed ID: 10973865 [TBL] [Abstract][Full Text] [Related]
4. Differences in reaction specificity toward lipoprotein X and abnormal LDL among 6 homogeneous assays for LDL-cholesterol. Matsushima K; Sugiuchi H; Anraku K; Nishimura H; Manabe M; Ikeda K; Ando Y; Kondo Y; Ishitsuka Y; Irikura M; Irie T Clin Chim Acta; 2015 Jan; 439():29-37. PubMed ID: 25286006 [TBL] [Abstract][Full Text] [Related]
5. [Differences in Measured Values among Homogenous Assay Reagents of LDL-C in LP-X Positive Serum Samples]. Abe M; Kurosawa H; Sato R; Ito K; Tomono Y; Manita D; Hirowatari Y; Yoshida H Rinsho Byori; 2015 Mar; 63(3):312-8. PubMed ID: 26524853 [TBL] [Abstract][Full Text] [Related]
6. Interference in a homogeneous assay for low-density lipoprotein cholesterol by lipoprotein X. Herzum I; Giehl C; Soufi M; Junclas H; Wahl HG Clin Chem Lab Med; 2007; 45(5):667-71. PubMed ID: 17484632 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of a homogeneous assay for measuring LDL-cholesterol in hyperlipidemic serum specimens. Yamashita S; Nakamura M; Koizumi H; Oku H; Sandoval JC; Tsubakio-Yamamoto K; Kawase M; Masuda D; Koseki M; Matsuura F; Shimomura I; Nishida M; Ishigami M J Atheroscler Thromb; 2008 Apr; 15(2):82-6. PubMed ID: 18385537 [TBL] [Abstract][Full Text] [Related]
8. Differential reactivity of two homogeneous LDL-cholesterol methods to LDL and VLDL subfractions, as demonstrated by ultracentrifugation and HPLC. Usui S; Kakuuchi H; Okamoto M; Mizukami Y; Okazaki M Clin Chem; 2002 Nov; 48(11):1946-54. PubMed ID: 12406980 [TBL] [Abstract][Full Text] [Related]
9. [Multicenter evaluation on different analyzers of three methods for direct HDL-cholesterol assay]. Egloff M; Léglise D; Duvillard L; Steinmetz J; Boyer MJ; Ruelland A; Agher R; Beucler I Ann Biol Clin (Paris); 1999; 57(5):561-72. PubMed ID: 10518058 [TBL] [Abstract][Full Text] [Related]
10. Homogeneous Assays for LDL-C and HDL-C are Reliable in Both the Postprandial and Fasting State. Miida T; Nishimura K; Hirayama S; Miyamoto Y; Nakamura M; Masuda D; Yamashita S; Ushiyama M; Komori T; Fujita N; Yokoyama S; Teramoto T J Atheroscler Thromb; 2017 Jun; 24(6):583-599. PubMed ID: 28321014 [TBL] [Abstract][Full Text] [Related]
11. Homogeneous assay for measuring low-density lipoprotein cholesterol in serum with triblock copolymer and alpha-cyclodextrin sulfate. Sugiuchi H; Irie T; Uji Y; Ueno T; Chaen T; Uekama K; Okabe H Clin Chem; 1998 Mar; 44(3):522-31. PubMed ID: 9510857 [TBL] [Abstract][Full Text] [Related]
12. Comparative study between anion-exchange HPLC and homogeneous assay methods in regard to the accuracy of high- and low-density lipoprotein cholesterol measurement. Kurosawa H; Yoshida H; Yanai H; Ogura Y; Hirowatari Y; Tada N Clin Biochem; 2007 Nov; 40(16-17):1291-6. PubMed ID: 17826753 [TBL] [Abstract][Full Text] [Related]
13. Comparison of calculated and direct low density lipoprotein cholesterol determinations in a routine laboratory. Amayo AA; Kirera S East Afr Med J; 2004 Mar; 81(3):154-8. PubMed ID: 15293974 [TBL] [Abstract][Full Text] [Related]
14. Analytical and clinical evaluation of two homogeneous assays for LDL-cholesterol in hyperlipidemic patients. Esteban-Salán M; Guimón-Bardesi A; de La Viuda-Unzueta JM; Azcarate-Ania MN; Pascual-Usandizaga P; Amoroto-Del-Río E Clin Chem; 2000 Aug; 46(8 Pt 1):1121-31. PubMed ID: 10926892 [TBL] [Abstract][Full Text] [Related]
15. Comparison of four direct homogeneous methods for the measurement of low-density lipoprotein cholesterol. Yamada K; Tsuji N; Fujita T; Tanaka M; Kuribayashi K; Kobayashi D; Watanabe N Clin Lab; 2010; 56(7-8):327-33. PubMed ID: 20857897 [TBL] [Abstract][Full Text] [Related]
16. Analytical and clinical performance of a homogeneous enzymatic LDL-cholesterol assay compared with the ultracentrifugation-dextran sulfate-Mg2+ method. Rifai N; Iannotti E; DeAngelis K; Law T Clin Chem; 1998 Jun; 44(6 Pt 1):1242-50. PubMed ID: 9625048 [TBL] [Abstract][Full Text] [Related]
17. Evaluation of a new homogenous method for detection of small dense LDL cholesterol: comparison with the LDL cholesterol profile obtained by density gradient ultracentrifugation. Albers JJ; Kennedy H; Marcovina SM Clin Chim Acta; 2011 Mar; 412(7-8):556-61. PubMed ID: 21156166 [TBL] [Abstract][Full Text] [Related]
18. Analytical performance and clinical efficacy of three routine procedures for LDL cholesterol measurement compared with the ultracentrifugation-dextran sulfate-Mg(2+) method. Nauck M; Rifai N Clin Chim Acta; 2000 Apr; 294(1-2):77-92. PubMed ID: 10727675 [TBL] [Abstract][Full Text] [Related]
19. Development of a homogeneous assay for measurement of small dense LDL cholesterol. Ito Y; Fujimura M; Ohta M; Hirano T Clin Chem; 2011 Jan; 57(1):57-65. PubMed ID: 21051530 [TBL] [Abstract][Full Text] [Related]
20. Reactions of direct LDL-cholesterol assays with pure LDL fraction and IDL: comparison of three homogeneous methods. Sakaue T; Hirano T; Yoshino G; Sakai K; Takeuchi H; Adachi M Clin Chim Acta; 2000 May; 295(1-2):97-106. PubMed ID: 10767397 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]