These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
773 related articles for article (PubMed ID: 16564693)
21. On line gamma-ray spectrometry at open sea. Tsabaris C; Ballas D Appl Radiat Isot; 2005 Jan; 62(1):83-9. PubMed ID: 15498689 [TBL] [Abstract][Full Text] [Related]
22. Monte Carlo calculation of response functions to gamma-ray point sources for a spherical NaI(Tl) detector. Yi CY; Hah SH Appl Radiat Isot; 2012 Sep; 70(9):2133-6. PubMed ID: 22424837 [TBL] [Abstract][Full Text] [Related]
23. Experimental HPGe coaxial detector response and efficiency compared to Monte Carlo simulations. Maidana NL; Vanin VR; García-Alvarez JA; Hermida-López M; Brualla L Appl Radiat Isot; 2016 Feb; 108():64-74. PubMed ID: 26704703 [TBL] [Abstract][Full Text] [Related]
24. Application of GESPECOR software for the calculation of coincidence summing effects in special cases. Arnold D; Sima O Appl Radiat Isot; 2004; 60(2-4):167-72. PubMed ID: 14987637 [TBL] [Abstract][Full Text] [Related]
25. Proficiency test for gamma spectroscopic analysis with a simulated fission product reference spectrum. Karhu P; De Geer LE; McWilliams E; Plenteda R; Werzi R Appl Radiat Isot; 2006; 64(10-11):1334-9. PubMed ID: 16567096 [TBL] [Abstract][Full Text] [Related]
26. A tunable monochromatic X-ray source for metrological studies in the 1-20 keV energy range: application to the measurement of attenuation coefficients. Lépy MC; Ferreux L; Plagnard J Appl Radiat Isot; 2004; 60(2-4):159-65. PubMed ID: 14987636 [TBL] [Abstract][Full Text] [Related]
27. The interplay between the statistical correlations of gamma-ray emission probabilities and efficiency calibration. Castro RM; Vanin VR; Helene O; Pascholati PR; Maidana NL; Dias MS; Koskinas MF Appl Radiat Isot; 2004; 60(2-4):185-90. PubMed ID: 14987640 [TBL] [Abstract][Full Text] [Related]
28. Monte Carlo calculations of calibration and geometry correction factors of a radionuclide calibrator. Olsovcová V; Havelka M Appl Radiat Isot; 2006; 64(10-11):1370-4. PubMed ID: 16546399 [TBL] [Abstract][Full Text] [Related]
29. Measurement of peak and total efficiencies of low-energy gamma-ray detectors with sources emitting photons in cascade. Korun M Appl Radiat Isot; 2004; 60(2-4):207-11. PubMed ID: 14987644 [TBL] [Abstract][Full Text] [Related]
30. Comparative measurements in dose calibrators and a gamma-ray spectrometer. Koskinas MF; Yamazaki IM; Bessa AC; Caldas LV; Dias MS Appl Radiat Isot; 2010; 68(4-5):589-91. PubMed ID: 19822439 [TBL] [Abstract][Full Text] [Related]
31. Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples. Baccouche S; Al-Azmi D; Karunakara N; Trabelsi A Appl Radiat Isot; 2012 Jan; 70(1):227-32. PubMed ID: 21852143 [TBL] [Abstract][Full Text] [Related]
32. An approximation for response function to gamma-rays of NaI(Tl) detectors up to 1.5 MeV. Cengiz A Appl Radiat Isot; 2008 Oct; 66(10):1371-6. PubMed ID: 18486481 [TBL] [Abstract][Full Text] [Related]
33. Non-destructive method of characterisation of radioactive waste containers using gamma spectroscopy and Monte Carlo techniques. Ridikas D; Feray S; Cometto M; Damoy F Radiat Prot Dosimetry; 2005; 115(1-4):113-6. PubMed ID: 16381694 [TBL] [Abstract][Full Text] [Related]
34. Application of GEANT4 simulation on calibration of HPGe detectors for cylindrical environmental samples. Nikolic JD; Jokovic D; Todorovic D; Rajacic M J Radiol Prot; 2014 Jun; 34(2):N47-55. PubMed ID: 24894534 [TBL] [Abstract][Full Text] [Related]
35. Characterization of a cosmic suppression spectrometer. Tran TT; Ferreux L; Lépy MC; Van Tao C; Pierre S Appl Radiat Isot; 2013 Nov; 81():114-8. PubMed ID: 23582499 [TBL] [Abstract][Full Text] [Related]
36. Performance assessment by Monte Carlo simulations of a prospective assembly of up to three HPGe detectors designed for superior detection efficiency and sensitivity. Jutier C; Douysset G Appl Radiat Isot; 2012 Sep; 70(9):1969-73. PubMed ID: 22440238 [TBL] [Abstract][Full Text] [Related]
37. Determination of the intensity of X- and gamma-ray emissions in the decay of 153Sm. Lépy MC; Amiot MN; Bé MM; Cassette P Appl Radiat Isot; 2006; 64(10-11):1428-34. PubMed ID: 16580221 [TBL] [Abstract][Full Text] [Related]
38. The determination of the efficiency of a Compton suppressed HPGe detector using Monte Carlo simulations. McNamara AL; Heijnis H; Fierro D; Reinhard MI J Environ Radioact; 2012 Apr; 106():1-7. PubMed ID: 22304994 [TBL] [Abstract][Full Text] [Related]
39. Error analysis for the in-vivo measurement of radionuclides in wounds: Monte Carlo study. Ahmed AS; Capello K; Sabourin T; Kramer GH Health Phys; 2010 Dec; 99(6):759-68. PubMed ID: 21068594 [TBL] [Abstract][Full Text] [Related]
40. Calibration of the 4pi gamma-ray spectrometer using a new numerical simulation approach. Nafee SS; Badawi MS; Abdel-Moneim AM; Mahmoud SA Appl Radiat Isot; 2010 Sep; 68(9):1746-53. PubMed ID: 20236831 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]