BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 16565198)

  • 1. The calculation of SAR from limb current in the female voxel phantom, NAOMI.
    Dimbylow PJ
    Radiat Prot Dosimetry; 2006; 121(3):236-9. PubMed ID: 16565198
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Resonance behaviour of whole-body averaged specific energy absorption rate (SAR) in the female voxel model, NAOMI.
    Dimbylow P
    Phys Med Biol; 2005 Sep; 50(17):4053-63. PubMed ID: 16177529
    [TBL] [Abstract][Full Text] [Related]  

  • 3. FDTD calculations of specific energy absorption rate in a seated voxel model of the human body from 10 MHz to 3 GHz.
    Findlay RP; Dimbylow PJ
    Phys Med Biol; 2006 May; 51(9):2339-52. PubMed ID: 16625046
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Calculated SAR distributions in a human voxel phantom due to the reflection of electromagnetic fields from a ground plane between 65 MHz and 2 GHz.
    Findlay RP; Dimbylow PJ
    Phys Med Biol; 2008 May; 53(9):2277-89. PubMed ID: 18401062
    [TBL] [Abstract][Full Text] [Related]  

  • 5. SAR in the mother and foetus for RF plane wave irradiation.
    Dimbylow P
    Phys Med Biol; 2007 Jul; 52(13):3791-802. PubMed ID: 17664577
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields.
    Dimbylow P
    Phys Med Biol; 2005 Mar; 50(6):1047-70. PubMed ID: 15798308
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of posture on FDTD calculations of specific absorption rate in a voxel model of the human body.
    Findlay RP; Dimbylow PJ
    Phys Med Biol; 2005 Aug; 50(16):3825-35. PubMed ID: 16077229
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Whole-body-averaged SAR from 50 MHz to 4 GHz in the University of Florida child voxel phantoms.
    Dimbylow P; Bolch W
    Phys Med Biol; 2007 Nov; 52(22):6639-49. PubMed ID: 17975288
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Variability analysis of SAR from 20 MHz to 2.4 GHz for different adult and child models using finite-difference time-domain.
    Conil E; Hadjem A; Lacroux F; Wong MF; Wiart J
    Phys Med Biol; 2008 Mar; 53(6):1511-25. PubMed ID: 18367785
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Empirical and theoretical dosimetry in support of whole body radio frequency (RF) exposure in seated human volunteers at 220 MHz.
    Allen SJ; Adair ER; Mylacraine KS; Hurt W; Ziriax J
    Bioelectromagnetics; 2005 Sep; 26(6):440-7. PubMed ID: 15931686
    [TBL] [Abstract][Full Text] [Related]  

  • 11. SAR variation study from 300 to 5000 MHz for 15 voxel models including different postures.
    Uusitupa T; Laakso I; Ilvonen S; Nikoskinen K
    Phys Med Biol; 2010 Feb; 55(4):1157-76. PubMed ID: 20107250
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spatial averaging of fields from half-wave dipole antennas and corresponding SAR calculations in the NORMAN human voxel model between 65 MHz and 2 GHz.
    Findlay RP; Dimbylow PJ
    Phys Med Biol; 2009 Apr; 54(8):2437-47. PubMed ID: 19336844
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Variations in calculated SAR with distance to the perfectly matched layer boundary for a human voxel model.
    Findlay RP; Dimbylow PJ
    Phys Med Biol; 2006 Dec; 51(23):N411-5. PubMed ID: 17110758
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A distributed equivalent magnetic current based FDTD method for the calculation of E-fields induced by gradient coils.
    Liu F; Crozier S
    J Magn Reson; 2004 Aug; 169(2):323-7. PubMed ID: 15261629
    [TBL] [Abstract][Full Text] [Related]  

  • 15. FDTD calculation of whole-body average SAR in adult and child models for frequencies from 30 MHz to 3 GHz.
    Wang J; Fujiwara O; Kodera S; Watanabe S
    Phys Med Biol; 2006 Sep; 51(17):4119-27. PubMed ID: 16912372
    [TBL] [Abstract][Full Text] [Related]  

  • 16. FDTD calculations of SAR for child voxel models in different postures between 10 MHz and 3 GHz.
    Findlay RP; Lee AK; Dimbylow PJ
    Radiat Prot Dosimetry; 2009 Aug; 135(4):226-31. PubMed ID: 19589878
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of SAR and induced current densities in adults and children exposed to electromagnetic fields from electronic article surveillance devices.
    Martínez-Búrdalo M; Sanchis A; Martín A; Villar R
    Phys Med Biol; 2010 Feb; 55(4):1041-55. PubMed ID: 20090190
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of SAR calculation algorithms for the finite-difference time-domain method.
    Laakso I; Uusitupa T; Ilvonen S
    Phys Med Biol; 2010 Aug; 55(15):N421-31. PubMed ID: 20647604
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of pregnant female, hybrid voxel-mathematical models and their application to the dosimetry of applied magnetic and electric fields at 50 Hz.
    Dimbylow P
    Phys Med Biol; 2006 May; 51(10):2383-94. PubMed ID: 16675859
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of the computational uncertainty of temperature rise and SAR in the eyes and brain under far-field exposure from 1 to 10 GHz.
    Laakso I
    Phys Med Biol; 2009 Jun; 54(11):3393-404. PubMed ID: 19436102
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.