These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 16565684)

  • 1. The compangle: a new goniometer for joint angle measurements of the hand. A technical note.
    Stam HJ; Ardon MS; den Ouden AC; Schreuders TA; Roebroeck ME
    Eura Medicophys; 2006 Mar; 42(1):37-40. PubMed ID: 16565684
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reliability of shoulder range of motion comparing a goniometer to a digital level.
    Mullaney MJ; McHugh MP; Johnson CP; Tyler TF
    Physiother Theory Pract; 2010 Jul; 26(5):327-33. PubMed ID: 20557263
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects.
    Brosseau L; Tousignant M; Budd J; Chartier N; Duciaume L; Plamondon S; O'Sullivan JP; O'Donoghue S; Balmer S
    Physiother Res Int; 1997; 2(3):150-66. PubMed ID: 9421820
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reliability of digital compass goniometer in knee joint range of motion measurement.
    Yaikwawongs N; Limpaphayom N; Wilairatana V
    J Med Assoc Thai; 2009 Apr; 92(4):517-22. PubMed ID: 19374303
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Palmar abduction: reliability of 6 measurement methods in healthy adults.
    de Kraker M; Selles RW; Schreuders TA; Stam HJ; Hovius SE
    J Hand Surg Am; 2009 Mar; 34(3):523-30. PubMed ID: 19258152
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy and reliability of three different techniques for manual goniometry for wrist motion: a cadaveric study.
    Carter TI; Pansy B; Wolff AL; Hillstrom HJ; Backus SI; Lenhoff M; Wolfe SW
    J Hand Surg Am; 2009 Oct; 34(8):1422-8. PubMed ID: 19703734
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Goniometry and linear assessments to monitor movement outcomes: are they reliable tools in burn survivors?
    Edgar D; Finlay V; Wu A; Wood F
    Burns; 2009 Feb; 35(1):58-62. PubMed ID: 18950951
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Reproducibility of measuring the finger joint angle with a sensory glove].
    Mentzel M; Hofmann F; Ebinger T; Jätzold B; Kinzl L; Wachter NJ
    Handchir Mikrochir Plast Chir; 2001 Jan; 33(1):59-63; discussion 63-4. PubMed ID: 11258036
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy and Validity of Goniometer and Visual Assessments of Angular Joint Positions of the Hand and Wrist.
    McVeigh KH; Murray PM; Heckman MG; Rawal B; Peterson JJ
    J Hand Surg Am; 2016 Apr; 41(4):e21-35. PubMed ID: 26810826
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement properties of a hand-held inclinometer during straight leg raise neurodynamic testing.
    Boyd BS
    Physiotherapy; 2012 Jun; 98(2):174-9. PubMed ID: 22507369
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Pollexograph: a new device for palmar abduction measurements of the thumb.
    de Kraker M; Selles RW; Schreuders TA; Hovius SE; Stam HJ
    J Hand Ther; 2009; 22(3):271-6; quiz 277. PubMed ID: 19278827
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intratester reliability and validity of concentric measurements using a new hand-held dynamometer.
    Janssen JC; Le-Ngoc L
    Arch Phys Med Rehabil; 2009 Sep; 90(9):1541-7. PubMed ID: 19735782
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Joint angle measurement: a comparative study of the reliability of goniometry and wire tracing for the hand.
    Ellis B; Bruton A; Goddard JR
    Clin Rehabil; 1997 Nov; 11(4):314-20. PubMed ID: 9408672
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reliability of goniometric measurements and visual estimates of knee range of motion obtained in a clinical setting.
    Watkins MA; Riddle DL; Lamb RL; Personius WJ
    Phys Ther; 1991 Feb; 71(2):90-6; discussion 96-7. PubMed ID: 1989012
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Viability of Hand and Wrist Photogoniometry.
    Meals CG; Saunders RJ; Desale S; Means KR
    Hand (N Y); 2018 May; 13(3):301-304. PubMed ID: 28391753
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation.
    MacDermid JC; Chesworth BM; Patterson S; Roth JH
    J Hand Ther; 1999; 12(3):187-92. PubMed ID: 10459526
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reliability, precision, accuracy, and validity of posterior shoulder tightness assessment in overhead athletes.
    Myers JB; Oyama S; Wassinger CA; Ricci RD; Abt JP; Conley KM; Lephart SM
    Am J Sports Med; 2007 Nov; 35(11):1922-30. PubMed ID: 17609529
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Test-retest reliability of the MicroFET 4 hand-grip dynamometer.
    Bohannon RW
    Physiother Theory Pract; 2006 Sep; 22(4):219-21. PubMed ID: 16920680
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reliability of goniometric measurements and visual estimates of ankle joint active range of motion obtained in a clinical setting.
    Youdas JW; Bogard CL; Suman VJ
    Arch Phys Med Rehabil; 1993 Oct; 74(10):1113-8. PubMed ID: 8215866
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Active movement measurements of the shoulder girdle in healthy subjects with goniometer and tape measure techniques: a study on reliability and validity.
    Nadeau S; Kovacs S; Gravel D; Piotte F; Moffet H; Gagnon D; Hébert LJ
    Physiother Theory Pract; 2007; 23(3):179-87. PubMed ID: 17558881
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.