370 related articles for article (PubMed ID: 16567460)
1. Elongation and structural properties of meniscal repair using suture techniques in distraction and shear force scenarios: biomechanical evaluation using a cyclic loading protocol.
Zantop T; Temmig K; Weimann A; Eggers AK; Raschke MJ; Petersen W
Am J Sports Med; 2006 May; 34(5):799-805. PubMed ID: 16567460
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical testing of suture-based meniscal repair devices containing ultrahigh-molecular-weight polyethylene suture: update 2011.
Barber FA; Herbert MA; Bava ED; Drew OR
Arthroscopy; 2012 Jun; 28(6):827-34. PubMed ID: 22317797
[TBL] [Abstract][Full Text] [Related]
3. [Biodegradable meniscus fixations: a comparative biomechanical study].
Seil R; Rupp S; Jurecka C; Georg T; Kohn D
Rev Chir Orthop Reparatrice Appar Mot; 2003 Feb; 89(1):35-43. PubMed ID: 12610434
[TBL] [Abstract][Full Text] [Related]
4. Strategies for repair of radial tears close to the meniscal rim--biomechanical analysis with a cyclic loading protocol.
Herbort M; Siam S; Lenschow S; Petersen W; Zantop T
Am J Sports Med; 2010 Nov; 38(11):2281-7. PubMed ID: 20889985
[TBL] [Abstract][Full Text] [Related]
5. Effect of lesion location on fixation strength of the meniscal viper repair system: an in vitro study using porcine menisci.
Chang HC; Caborn DN; Nyland J; Burden R
Arthroscopy; 2006 Apr; 22(4):394-9. PubMed ID: 16581451
[TBL] [Abstract][Full Text] [Related]
6. New suture method for radial tears of the meniscus: biomechanical analysis of cross-suture and double horizontal suture techniques using cyclic load testing.
Matsubara H; Okazaki K; Izawa T; Tashiro Y; Matsuda S; Nishimura T; Nakanishi Y; Kawamura H; Iwamoto Y
Am J Sports Med; 2012 Feb; 40(2):414-8. PubMed ID: 22016457
[TBL] [Abstract][Full Text] [Related]
7. Cyclic testing of meniscal sutures.
Seil R; Rupp S; Kohn DM
Arthroscopy; 2000; 16(5):505-10. PubMed ID: 10882446
[TBL] [Abstract][Full Text] [Related]
8. Tensile and shear loading stability of all-inside meniscal repairs: an in vitro biomechanical evaluation.
Brucker PU; Favre P; Puskas GJ; von Campe A; Meyer DC; Koch PP
Am J Sports Med; 2010 Sep; 38(9):1838-44. PubMed ID: 20805413
[TBL] [Abstract][Full Text] [Related]
9. The effect of meniscus compression on the biomechanical properties of repaired meniscal lesions. Winner of the AGA-DonJoy Award 2003.
Staerke C; Bochwitz C; Groebel KH; Unterhauser F; Becker R
Arch Orthop Trauma Surg; 2004 May; 124(4):221-5. PubMed ID: 14963723
[TBL] [Abstract][Full Text] [Related]
10. Failure strength of repair devices versus meniscus suturing techniques.
Aşík M; Sener N
Knee Surg Sports Traumatol Arthrosc; 2002 Jan; 10(1):25-9. PubMed ID: 11819017
[TBL] [Abstract][Full Text] [Related]
11. A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.
Bhatia S; Civitarese DM; Turnbull TL; LaPrade CM; Nitri M; Wijdicks CA; LaPrade RF
Am J Sports Med; 2016 Mar; 44(3):639-45. PubMed ID: 26646516
[TBL] [Abstract][Full Text] [Related]
12. Biomechanical evaluation of meniscal repair systems: a comparison of the Meniscal Viper Repair System, the vertical mattress FasT-Fix Device, and vertical mattress ethibond sutures.
Chang HC; Nyland J; Caborn DN; Burden R
Am J Sports Med; 2005 Dec; 33(12):1846-52. PubMed ID: 16157854
[TBL] [Abstract][Full Text] [Related]
13. Biomechanical testing of a shape memory alloy suture in a meniscal suture model.
Lamprakis AA; Fortis AP; Kostopoulos V; Vlasis K
Arthroscopy; 2009 Jun; 25(6):632-8. PubMed ID: 19501294
[TBL] [Abstract][Full Text] [Related]
14. The influence of suture material on the strength of horizontal mattress suture configuration for meniscus repair.
Hapa O; Akşahin E; Erduran M; Davul S; Havitçioğlu H; LaPrade RF; Bozdağ E; Sünbüloğlu E
Knee; 2013 Dec; 20(6):577-80. PubMed ID: 23340094
[TBL] [Abstract][Full Text] [Related]
15. Repair of peripheral vertical meniscus lesions in porcine menisci: in vitro biomechanical testing of 3 different meniscus repair devices.
Lee YH; Nyland J; Burden R; Caborn DN
Am J Sports Med; 2013 May; 41(5):1074-81. PubMed ID: 23475943
[TBL] [Abstract][Full Text] [Related]
16. All-inside meniscal repair devices compared with their matched inside-out vertical mattress suture repair: introducing 10,000 and 100,000 loading cycles.
Rosso C; Müller S; Buckland DM; Schwenk T; Zimmermann S; de Wild M; Valderrabano V
Am J Sports Med; 2014 Sep; 42(9):2226-33. PubMed ID: 24966304
[TBL] [Abstract][Full Text] [Related]
17. Cyclic testing of flexible all-inside meniscus suture anchors: biomechanical analysis.
Zantop T; Eggers AK; Musahl V; Weimann A; Petersen W
Am J Sports Med; 2005 Mar; 33(3):388-94. PubMed ID: 15716254
[TBL] [Abstract][Full Text] [Related]
18. Biomechanical evaluation of different suture techniques for arthroscopic transtibial pull-out repair of posterior medial meniscus root tears.
Feucht MJ; Grande E; Brunhuber J; Burgkart R; Imhoff AB; Braun S
Am J Sports Med; 2013 Dec; 41(12):2784-90. PubMed ID: 24013348
[TBL] [Abstract][Full Text] [Related]
19. Meniscal repair devices: a clinical and biomechanical literature review.
Farng E; Sherman O
Arthroscopy; 2004 Mar; 20(3):273-86. PubMed ID: 15007316
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical Comparison of 3 Novel Repair Techniques for Radial Tears of the Medial Meniscus: The 2-Tunnel Transtibial Technique, a "Hybrid" Horizontal and Vertical Mattress Suture Configuration, and a Combined "Hybrid Tunnel" Technique.
Buckley PS; Kemler BR; Robbins CM; Aman ZS; Storaci HW; Dornan GJ; LaPrade RF
Am J Sports Med; 2019 Mar; 47(3):651-658. PubMed ID: 30624953
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]