458 related articles for article (PubMed ID: 16569508)
1. Loss in mechanical contact of cementless acetabular prostheses due to post-operative weight bearing: a biomechanical model.
Bellini CM; Galbusera F; Ceroni RG; Raimondi MT
Med Eng Phys; 2007 Mar; 29(2):175-81. PubMed ID: 16569508
[TBL] [Abstract][Full Text] [Related]
2. [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].
Morscher EW; Widmer KH; Bereiter H; Elke R; Schenk R
Acta Chir Orthop Traumatol Cech; 2002; 69(1):8-15. PubMed ID: 11951572
[TBL] [Abstract][Full Text] [Related]
3. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
[TBL] [Abstract][Full Text] [Related]
4. Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up.
Zwartelé RE; Olsthoorn PG; Pöll RG; Brand R; Doets HC
Arch Orthop Trauma Surg; 2008 Dec; 128(12):1379-86. PubMed ID: 18758793
[TBL] [Abstract][Full Text] [Related]
5. Finite element simulation of early creep and wear in total hip arthroplasty.
Bevill SL; Bevill GR; Penmetsa JR; Petrella AJ; Rullkoetter PJ
J Biomech; 2005 Dec; 38(12):2365-74. PubMed ID: 16214484
[TBL] [Abstract][Full Text] [Related]
6. Acetabular cup geometry and bone-implant interference have more influence on initial periprosthetic joint space than joint loading and surgical cup insertion.
Ong KL; Lehman J; Notz WI; Santner TJ; Bartel DL
J Biomech Eng; 2006 Apr; 128(2):169-75. PubMed ID: 16524327
[TBL] [Abstract][Full Text] [Related]
7. Stair climbing is more critical than walking in pre-clinical assessment of primary stability in cementless THA in vitro.
Kassi JP; Heller MO; Stoeckle U; Perka C; Duda GN
J Biomech; 2005 May; 38(5):1143-54. PubMed ID: 15797595
[TBL] [Abstract][Full Text] [Related]
8. [Initial stability of press-fit acetabular cups--an in-vitro study].
Wetzel R; Simnacher M; Scheller G
Biomed Tech (Berl); 2005 Dec; 50(12):400-3. PubMed ID: 16429943
[TBL] [Abstract][Full Text] [Related]
9. Primary stability of an anatomical cementless hip stem: a statistical analysis.
Viceconti M; Brusi G; Pancanti A; Cristofolini L
J Biomech; 2006; 39(7):1169-79. PubMed ID: 15927191
[TBL] [Abstract][Full Text] [Related]
10. A novel method to assess primary stability of press-fit acetabular cups.
Crosnier EA; Keogh PS; Miles AW
Proc Inst Mech Eng H; 2014 Nov; 228(11):1126-34. PubMed ID: 25384445
[TBL] [Abstract][Full Text] [Related]
11. [Effect of socket preparation on primary stability of an elliptical acetabular component].
Pitto RP; Hofmeister V
Biomed Tech (Berl); 1998 Sep; 43(9):257-60. PubMed ID: 9785621
[TBL] [Abstract][Full Text] [Related]
12. Finite element analysis of shear stresses at the implant-bone interface of an acetabular press-fit cup during impingement.
Voigt C; Klöhn C; Bader R; von Salis-Soglio G; Scholz R
Biomed Tech (Berl); 2007 Apr; 52(2):208-15. PubMed ID: 17408381
[TBL] [Abstract][Full Text] [Related]
13. The potential for bone loss in acetabular structures following THA.
Manley MT; Ong KL; Kurtz SM
Clin Orthop Relat Res; 2006 Dec; 453():246-53. PubMed ID: 17006368
[TBL] [Abstract][Full Text] [Related]
14. Bone remodelling around uncemented metallic and ceramic acetabular components.
Ghosh R; Mukherjee K; Gupta S
Proc Inst Mech Eng H; 2013 May; 227(5):490-502. PubMed ID: 23637259
[TBL] [Abstract][Full Text] [Related]
15. Cementless stem fixation and primary stability under physiological-like loads in vitro.
Heller MO; Kassi JP; Perka C; Duda GN
Biomed Tech (Berl); 2005 Dec; 50(12):394-9. PubMed ID: 16429942
[TBL] [Abstract][Full Text] [Related]
16. Design factors influencing performance of constrained acetabular liners: finite element characterization.
Bouchard SM; Stewart KJ; Pedersen DR; Callaghan JJ; Brown TD
J Biomech; 2006; 39(5):885-93. PubMed ID: 16488227
[TBL] [Abstract][Full Text] [Related]
17. Problematic sites of third body embedment in polyethylene for total hip wear acceleration.
Lundberg HJ; Stewart KJ; Pedersen DR; Callaghan JJ; Brown TD
J Biomech; 2006; 39(7):1208-16. PubMed ID: 15894322
[TBL] [Abstract][Full Text] [Related]
18. Robust design for acetabular cup stability accounting for patient and surgical variability.
Ong KL; Santner TJ; Bartel DL
J Biomech Eng; 2008 Jun; 130(3):031001. PubMed ID: 18532850
[TBL] [Abstract][Full Text] [Related]
19. Can the rasp be used to predict intra-operatively the primary stability that can be achieved by press-fitting the stem in cementless hip arthroplasty?
Varini E; Cristofolini L; Traina F; Viceconti M; Toni A
Clin Biomech (Bristol, Avon); 2008 May; 23(4):408-14. PubMed ID: 18068878
[TBL] [Abstract][Full Text] [Related]
20. Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses.
Mak M; Jin Z; Fisher J; Stewart TD
J Arthroplasty; 2011 Jan; 26(1):131-6. PubMed ID: 20149581
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]