BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

194 related articles for article (PubMed ID: 16580476)

  • 1. Pneumatic tube delivery system for blood samples reduces turnaround times without affecting sample quality.
    Fernandes CM; Worster A; Eva K; Hill S; McCallum C
    J Emerg Nurs; 2006 Apr; 32(2):139-43. PubMed ID: 16580476
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An episode of increased hemolysis due to a defective pneumatic air tube delivery system.
    Ellis G
    Clin Biochem; 2009 Aug; 42(12):1265-9. PubMed ID: 19445913
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?
    Phelan MP; Reineks EZ; Hustey FM; Berriochoa JP; Podolsky SR; Meldon S; Schold JD; Chamberlin J; Procop GW
    West J Emerg Med; 2016 Sep; 17(5):557-60. PubMed ID: 27625719
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Effect of Pneumatic Tube Systems on the Hemolysis of Biochemistry Blood Samples.
    Cakirca G; Erdal H
    J Emerg Nurs; 2017 May; 43(3):255-258. PubMed ID: 28359708
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The impact of a pneumatic tube and computerized physician order management on laboratory turnaround time.
    Guss DA; Chan TC; Killeen JP
    Ann Emerg Med; 2008 Feb; 51(2):181-5. PubMed ID: 17467118
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preanalytical influence of pneumatic tube delivery system on results of routine biochemistry and haematology analysis.
    Petit M; Mine L; Pascreau T; Brouzes C; Majoux S; Borgel D; Beaudeux JL; Lasne D; Hennequin C
    Ann Biol Clin (Paris); 2017 Dec; 75(6):703-712. PubMed ID: 29043982
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of pneumatic tube delivery system rate and distance on hemolysis of blood specimens.
    Evliyaoğlu O; Toprak G; Tekin A; Başarali MK; Kilinç C; Colpan L
    J Clin Lab Anal; 2012 Feb; 26(2):66-9. PubMed ID: 22467320
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis.
    Tiwari AK; Pandey P; Dixit S; Raina V
    Clin Chem Lab Med; 2011 Nov; 50(3):471-4. PubMed ID: 22070350
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of pneumatic tube delivery system on laboratory results.
    Makhlouf R; Fendri S; Jallouli D; Labiadh Z; Fritis L; Chaabouni K; Elleuch A; Ayadi FM
    Ann Clin Biochem; 2024 May; 61(3):210-217. PubMed ID: 37921518
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Pneumatic tube system for transport of laboratory samples: preanalytical aspects].
    Tóth J; Lenkey Á; V Oláh A; Köteles J; Kissné Sziráki V; Kerényi A; Kappelmayer J
    Orv Hetil; 2014 Jul; 155(28):1113-20. PubMed ID: 25002315
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pneumatic tube validation: Reducing the need for donor samples by integrating a vial-embedded data logger.
    Stangerup I; Broell F; Hoop JV; Sennels HP
    Ann Clin Biochem; 2021 Jul; 58(4):280-288. PubMed ID: 33478238
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Smartphone Application Monitoring of Acceleration Forces During Pneumatic Tube System Transport of Emergency Department Patient Samples.
    Heireman L; Stroobants J; Uyttenbroeck W; Goossens Y; Dreezen C; Luyts D; Broeck LVD; Delanghe J; Heylen E; Mahieu B
    Clin Lab; 2018 Jul; 64(7):1297-1304. PubMed ID: 30146841
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of pneumatic tube system with manual transport for routine chemistry, hematology, coagulation and blood gas tests.
    Pupek A; Matthewson B; Whitman E; Fullarton R; Chen Y
    Clin Chem Lab Med; 2017 Aug; 55(10):1537-1544. PubMed ID: 28432841
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of clinical data and acceleration profiles to validate pneumatic transportation systems.
    Gils C; Broell F; Vinholt PJ; Nielsen C; Nybo M
    Clin Chem Lab Med; 2020 Mar; 58(4):560-568. PubMed ID: 31804954
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.
    Böckel-Frohnhöfer N; Hübner U; Hummel B; Geisel J
    Scand J Clin Lab Invest; 2014 Oct; 74(7):599-602. PubMed ID: 24909156
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Blood sample tube transporting system versus point of care technology in an emergency department; effect on time from collection to reporting? A randomised trial.
    Nørgaard B; Mogensen CB
    Scand J Trauma Resusc Emerg Med; 2012 Oct; 20():71. PubMed ID: 23044180
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Changes in emergency department turnaround time performance from 1990 to 1993. A comparison of two College of American Pathologists Q-probes studies.
    Steindel SJ; Howanitz PJ
    Arch Pathol Lab Med; 1997 Oct; 121(10):1031-41. PubMed ID: 9341581
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of a soft-handling computerized pneumatic tube specimen delivery system. Effects on analytical results and turnaround time.
    Keshgegian AA; Bull GE
    Am J Clin Pathol; 1992 Apr; 97(4):535-40. PubMed ID: 1553919
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Physician satisfaction and emergency department laboratory test turnaround time.
    Steindel SJ; Howanitz PJ
    Arch Pathol Lab Med; 2001 Jul; 125(7):863-71. PubMed ID: 11419969
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pneumatic tube system induced haemolysis: assessing sample type susceptibility to haemolysis.
    Sodi R; Darn SM; Stott A
    Ann Clin Biochem; 2004 May; 41(Pt 3):237-40. PubMed ID: 15117440
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.