These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

257 related articles for article (PubMed ID: 16581453)

  • 21. Biomechanical testing of a shape memory alloy suture in a meniscal suture model.
    Lamprakis AA; Fortis AP; Kostopoulos V; Vlasis K
    Arthroscopy; 2009 Jun; 25(6):632-8. PubMed ID: 19501294
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Meniscal repair using the FasT-Fix all-inside meniscal repair device.
    Haas AL; Schepsis AA; Hornstein J; Edgar CM
    Arthroscopy; 2005 Feb; 21(2):167-75. PubMed ID: 15689865
    [TBL] [Abstract][Full Text] [Related]  

  • 23. All-inside meniscal repair devices compared with their matched inside-out vertical mattress suture repair: introducing 10,000 and 100,000 loading cycles.
    Rosso C; Müller S; Buckland DM; Schwenk T; Zimmermann S; de Wild M; Valderrabano V
    Am J Sports Med; 2014 Sep; 42(9):2226-33. PubMed ID: 24966304
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Cyclic test comparison of all-inside device and inside-out sutures for radial meniscus lesion repair: an in vitro porcine model study.
    Lee YH; Nyland J; Burden R; Caborn DN
    Arthroscopy; 2012 Dec; 28(12):1873-81. PubMed ID: 23085200
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Biodegradable meniscus fixations: a comparative biomechanical study].
    Seil R; Rupp S; Jurecka C; Georg T; Kohn D
    Rev Chir Orthop Reparatrice Appar Mot; 2003 Feb; 89(1):35-43. PubMed ID: 12610434
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Mechanical comparison of meniscal repair devices with mattress suture devices in vitro.
    Aros BC; Pedroza A; Vasileff WK; Litsky AS; Flanigan DC
    Knee Surg Sports Traumatol Arthrosc; 2010 Nov; 18(11):1594-8. PubMed ID: 20532866
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Horizontal suture placement influences meniscal repair fixation strength.
    Kocabey Y; Taser O; Nyland J; Ince H; Sahin F; Sunbuloglu E; Baysal G
    Knee Surg Sports Traumatol Arthrosc; 2013 Mar; 21(3):615-9. PubMed ID: 22484371
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Pull-out and shear failure strengths of arthroscopic meniscal repair systems.
    Fisher SR; Markel DC; Koman JD; Atkinson TS
    Knee Surg Sports Traumatol Arthrosc; 2002 Sep; 10(5):294-9. PubMed ID: 12355304
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of all-inside meniscal repair devices with matched inside-out suture repair.
    Rosso C; Kovtun K; Dow W; McKenzie B; Nazarian A; DeAngelis JP; Ramappa AJ
    Am J Sports Med; 2011 Dec; 39(12):2634-9. PubMed ID: 21997730
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical comparison of tibial eminence fracture fixation with high-strength suture, EndoButton, and suture anchor.
    Hapa O; Barber FA; Süner G; Özden R; Davul S; Bozdağ E; Sünbüloğlu E
    Arthroscopy; 2012 May; 28(5):681-7. PubMed ID: 22284410
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Outside-in continuous suturing is superior to interrupted suturing for repairing peripheral meniscus lesions: an in vitro biomechanical study using a porcine model.
    Breland R; Nyland J; Lee YH; Culy D; Burden R; Caborn D
    Arthroscopy; 2013 Dec; 29(12):1974-80. PubMed ID: 24140141
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Pullout strength of meniscal repair after cyclic loading: comparison of vertical, horizontal, and oblique suture techniques.
    Kocabey Y; Taser O; Nyland J; Doral MN; Demirhan M; Caborn DN; Sarban S
    Knee Surg Sports Traumatol Arthrosc; 2006 Oct; 14(10):998-1003. PubMed ID: 16673145
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Cyclic testing of meniscal sutures.
    Seil R; Rupp S; Kohn DM
    Arthroscopy; 2000; 16(5):505-10. PubMed ID: 10882446
    [TBL] [Abstract][Full Text] [Related]  

  • 34. New suture method for radial tears of the meniscus: biomechanical analysis of cross-suture and double horizontal suture techniques using cyclic load testing.
    Matsubara H; Okazaki K; Izawa T; Tashiro Y; Matsuda S; Nishimura T; Nakanishi Y; Kawamura H; Iwamoto Y
    Am J Sports Med; 2012 Feb; 40(2):414-8. PubMed ID: 22016457
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation.
    Zantop T; Eggers AK; Musahl V; Weimann A; Hassenpflug J; Petersen W
    Knee Surg Sports Traumatol Arthrosc; 2004 Jul; 12(4):317-24. PubMed ID: 14689168
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Shear force at failure and stiffness of all-inside meniscal repair devices.
    Kesto WK; Esquivel AO; Markel DC
    J Knee Surg; 2013 Dec; 26(6):435-40. PubMed ID: 23729312
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Biomechanical Characteristics of All-Suture Meniscal Repair Devices Compared With PEEK-Anchored Devices and Inside-Out Suture for Meniscal Repair: A Porcine Study.
    Barber FA; Davidson PA; Henninger HB
    Orthop J Sports Med; 2024 May; 12(5):23259671241245127. PubMed ID: 38799548
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A biomechanical comparison of all-inside meniscus repair techniques.
    Chang JH; Shen HC; Huang GS; Pan RY; Wu CF; Lee CH; Chen Q
    J Surg Res; 2009 Jul; 155(1):82-8. PubMed ID: 19328497
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Elongation and structural properties of meniscal repair using suture techniques in distraction and shear force scenarios: biomechanical evaluation using a cyclic loading protocol.
    Zantop T; Temmig K; Weimann A; Eggers AK; Raschke MJ; Petersen W
    Am J Sports Med; 2006 May; 34(5):799-805. PubMed ID: 16567460
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Improving the biomechanical properties of the T-fix using oblique direction: in vitro study on bovine menisci.
    Karaoglu S; Duygulu F; Inan M; Baktir A
    Knee Surg Sports Traumatol Arthrosc; 2002 May; 10(3):198-201. PubMed ID: 12012039
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.