462 related articles for article (PubMed ID: 16585848)
1. Polymer gel dosimetry for the TG-43 dosimetric characterization of a new 125I interstitial brachytherapy seed.
Papagiannis P; Pantelis E; Georgiou E; Karaiskos P; Angelopoulos A; Sakelliou L; Stiliaris S; Baltas D; Seimenis I
Phys Med Biol; 2006 Apr; 51(8):2101-11. PubMed ID: 16585848
[TBL] [Abstract][Full Text] [Related]
2. Polymer gel dosimetry close to an 125I interstitial brachytherapy seed.
Pantelis E; Lymperopoulou G; Papagiannis P; Sakelliou L; Stiliaris E; Sandilos P; Seimenis I; Kozicki M; Rosiak JM
Phys Med Biol; 2005 Sep; 50(18):4371-84. PubMed ID: 16148399
[TBL] [Abstract][Full Text] [Related]
3. Monte Carlo and thermoluminescence dosimetry of the new IsoSeed model I25.S17 125I interstitial brachytherapy seed.
Lymperopoulou G; Papagiannis P; Sakelliou L; Karaiskos P; Sandilos P; Przykutta A; Baltas D
Med Phys; 2005 Nov; 32(11):3313-7. PubMed ID: 16370418
[TBL] [Abstract][Full Text] [Related]
4. A Monte Carlo brachytherapy study for dose distribution prediction in an inhomogeneous medium.
Slate LJ; Elson HR; Lamba MA; Kassing WM; Soldano M; Barrett WL
Med Dosim; 2004; 29(4):271-8. PubMed ID: 15528069
[TBL] [Abstract][Full Text] [Related]
5. A Monte Carlo evaluation of the dosimetric characteristics of the EchoSeed Model 6733 (125)I brachytherapy source.
Sowards KT; Meigooni AS
Brachytherapy; 2002; 1(4):227-32. PubMed ID: 15062171
[TBL] [Abstract][Full Text] [Related]
6. Dosimetric parameters estimation using PENELOPE Monte-Carlo simulation code: Model 6711 a 125I brachytherapy seed.
Rodríguez EA; Alcón EP; Rodriguez ML; Gutt F; de Almeida CE
Appl Radiat Isot; 2005 Jul; 63(1):41-8. PubMed ID: 15866446
[TBL] [Abstract][Full Text] [Related]
7. Dosimetric characteristic of a new 125I brachytherapy source.
Sadeghi M; Khanmohammadi Z
Radiat Prot Dosimetry; 2011 Nov; 147(3):451-6. PubMed ID: 21233096
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo calculations of AAPM Task Group Report No. 43 dosimetry parameters for the (125)I I-Seed AgX100 source model.
Mourtada F; Mikell J; Ibbott G
Brachytherapy; 2012; 11(3):237-44. PubMed ID: 21816684
[TBL] [Abstract][Full Text] [Related]
9. Experimental measurements and Monte Carlo calculations of dosimetric parameters of the IRA1-103Pd brachytherapy source.
Sadeghi M; Hosseini SH; Raisali G
Appl Radiat Isot; 2008 Oct; 66(10):1431-7. PubMed ID: 18387806
[TBL] [Abstract][Full Text] [Related]
10. Study of the IsoAid ADVANTAGE (125)I brachytherapy source dosimetric parameters using Monte Carlo simulation.
Sadeghi M; Hamed Hosseini S
Appl Radiat Isot; 2010 Jan; 68(1):211-3. PubMed ID: 19762248
[TBL] [Abstract][Full Text] [Related]
11. Experimental determination of the Task Group-43 dosimetric parameters of the new I25.S17plus (125)I brachytherapy source.
Moutsatsos A; Pantelis E; Papagiannis P; Baltas D
Brachytherapy; 2014; 13(6):618-26. PubMed ID: 25108795
[TBL] [Abstract][Full Text] [Related]
12. A modern Monte Carlo investigation of the TG-43 dosimetry parameters for an 125I seed already having AAPM consensus data.
Aryal P; Molloy JA; Rivard MJ
Med Phys; 2014 Feb; 41(2):021702. PubMed ID: 24506593
[TBL] [Abstract][Full Text] [Related]
13. Experimental and theoretical dosimetry of a new polymer encapsulated iodine-125 source--SmartSeed: dosimetric impact of fluorescence x rays.
Abboud F; Hollows M; Scalliet P; Vynckier S
Med Phys; 2010 May; 37(5):2054-62. PubMed ID: 20527538
[TBL] [Abstract][Full Text] [Related]
14. Thermoluminescent dosimetry of the Symmetra 125I model I25.S06 interstitial brachytherapy seed.
Patel NS; Chiu-Tsao ST; Williamson JF; Fan P; Duckworth T; Shasha D; Harrison LB
Med Phys; 2001 Aug; 28(8):1761-9. PubMed ID: 11548947
[TBL] [Abstract][Full Text] [Related]
15. The use of new GAFCHROMIC EBT film for 125I seed dosimetry in Solid Water phantom.
Chiu-Tsao ST; Medich D; Munro J
Med Phys; 2008 Aug; 35(8):3787-99. PubMed ID: 18777938
[TBL] [Abstract][Full Text] [Related]
16. Monte Carlo and experimental characterization of the first AMIRS 103Pd brachytherapy source.
Raisali G; Ghonchehnazi MG; Shokrani P; Sadeghi M
Appl Radiat Isot; 2008 Dec; 66(12):1856-60. PubMed ID: 18657981
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of the dosimetric performance of BANG3 polymer gel.
MacDougall ND; Miquel ME; Wilson DJ; Keevil SF; Smith MA
Phys Med Biol; 2005 Apr; 50(8):1717-26. PubMed ID: 15815092
[TBL] [Abstract][Full Text] [Related]
18. Dose verification of single shot gamma knife applications using VIPAR polymer gel and MRI.
Karaiskos P; Petrokokkinos L; Tatsis E; Angelopoulos A; Baras P; Kozicki M; Papagiannis P; Rosiak JM; Sakelliou L; Sandilos P; Vlachos L
Phys Med Biol; 2005 Mar; 50(6):1235-50. PubMed ID: 15798319
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism.
Ho Than MT; Munro Iii JJ; Medich DC
J Appl Clin Med Phys; 2015 May; 16(3):5270. PubMed ID: 26103489
[TBL] [Abstract][Full Text] [Related]
20. Dosimetric characteristics of the Pharma Seed model BT-125-I source.
Popescu CC; Wise J; Sowards K; Meigooni AS; Ibbott GS
Med Phys; 2000 Sep; 27(9):2174-81. PubMed ID: 11011748
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]