These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 16594449)

  • 21. [A comparisive study between intramedullary interlocking nail and plate-screw fixation in the treatment of tibial shaft fractures].
    Huang P; Tang PF; Yao Q; Liang YT; Tao S; Zhang Q; Guo YZ; Liang XD; Wang Y
    Zhongguo Gu Shang; 2008 Apr; 21(4):261-3. PubMed ID: 19102183
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Biomechanical comparison of callus over a locked intramedullary nail in various segmental bone defects in a sheep model.
    Tyllianakis M; Deligianni D; Panagopoulos A; Pappas M; Sourgiadaki E; Mavrilas D; Papadopoulos A
    Med Sci Monit; 2007 May; 13(5):BR125-30. PubMed ID: 17476191
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A nickel-titanium shape memory alloy plate for contactless inverse dynamization after internal fixation in a sheep tibia fracture model: A pilot study.
    Decker S; Krämer M; Marten AK; Pfeifer R; Wesling V; Neunaber C; Hurschler C; Krettek C; Müller CW
    Technol Health Care; 2015; 23(4):463-74. PubMed ID: 26409909
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate-rod fixation applied to experimentally induced gap fractures in canine femora.
    Goh CS; Santoni BG; Puttlitz CM; Palmer RH
    Am J Vet Res; 2009 Jan; 70(1):23-9. PubMed ID: 19119945
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of plate luting, using an in vivo ovine osteotomy model.
    Richardson DW; Nunamaker DM
    Am J Vet Res; 1991 Sep; 52(9):1468-73. PubMed ID: 1952335
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical analysis of distal femur fracture fixation: fixed-angle screw-plate construct versus condylar blade plate.
    Higgins TF; Pittman G; Hines J; Bachus KN
    J Orthop Trauma; 2007 Jan; 21(1):43-6. PubMed ID: 17211268
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Volar versus dorsal fixed-angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanic study.
    McCall TA; Conrad B; Badman B; Wright T
    J Hand Surg Am; 2007; 32(6):806-12. PubMed ID: 17606058
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibial fracture: a retrospective study of 32 patients.
    Hasenboehler E; Rikli D; Babst R
    Injury; 2007 Mar; 38(3):365-70. PubMed ID: 17241634
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Mechanical effects of high density polyethylene dynamic compression plate hole inserts on bone-plate constructs.
    Sullivan EK; Nunamaker DM; Richardson DW
    Vet Comp Orthop Traumatol; 2005; 18(2):63-6. PubMed ID: 16594199
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate.
    Krischak GD; Augat P; Beck A; Arand M; Baier B; Blakytny R; Gebhard F; Claes L
    Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1112-8. PubMed ID: 17900766
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Locked vs. unlocked plate osteosynthesis of the proximal humerus - a biomechanical study.
    Seide K; Triebe J; Faschingbauer M; Schulz AP; Püschel K; Mehrtens G; Jürgens Ch
    Clin Biomech (Bristol, Avon); 2007 Feb; 22(2):176-82. PubMed ID: 17134800
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Locking compression plate osteosynthesis of complicated mandibular fractures in six horses.
    Kuemmerle JM; Kummer M; Auer JA; Nitzl D; Fürst AE
    Vet Comp Orthop Traumatol; 2009; 22(1):54-8. PubMed ID: 19151871
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Influence of an additional locking screw on fracture reduction after volar fixed-angle plating-introduction of the "protection screw" in an extra-articular distal radius fracture model.
    Weninger P; Schueller M; Drobetz H; Jamek M; Redl H; Tschegg E
    J Trauma; 2009 Oct; 67(4):746-51. PubMed ID: 19820581
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Bone healing following two methods of non-rigid tibial osteotomy repair in the dog.
    Coetzee GL
    J S Afr Vet Assoc; 1993 Mar; 64(1):20-7. PubMed ID: 8496890
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Rigid or sliding plate. A mechanical evaluation of osteotomy fixation in sheep.
    Panagiotopoulos E; Fortis AP; Lambiris E; Kostopoulos V
    Clin Orthop Relat Res; 1999 Jan; (358):244-9. PubMed ID: 9973997
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Biomechanical comparison of screws and plates for hallux valgus opening-wedge and Ludloff osteotomies.
    Hofstaetter SG; Glisson RR; Alitz CJ; Trnka HJ; Easley ME
    Clin Biomech (Bristol, Avon); 2008 Jan; 23(1):101-8. PubMed ID: 17910899
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Biomechanical properties of a novel locking compression plate to stabilize oblique tibial osteotomies in buffaloes.
    Ahmad RA; Aithal HP; Amarpal ; Kinjavdekar P; Gope PC; Madhu DN
    Vet Surg; 2021 Feb; 50(2):444-454. PubMed ID: 33325099
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biomechanical considerations in plate osteosynthesis: the effect of plate-to-bone compression with and without angular screw stability.
    Stoffel K; Lorenz KU; Kuster MS
    J Orthop Trauma; 2007 Jul; 21(6):362-8. PubMed ID: 17620993
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Biomechanical evaluation of locking plate radial shaft fixation: unicortical locking fixation versus mixed bicortical and unicortical fixation in a sawbone model.
    Roberts JW; Grindel SI; Rebholz B; Wang M
    J Hand Surg Am; 2007 Sep; 32(7):971-5. PubMed ID: 17826548
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Treatment of femoral fracture on previous implants with minimally-invasive surgery and total weight-bearing: benefit of locking plate. Preliminary report].
    Ehlinger M; Cognet JM; Simon P
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Feb; 94(1):26-36. PubMed ID: 18342027
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.