These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

429 related articles for article (PubMed ID: 16598724)

  • 1. Partial-k-space acquisition method for improved SNR efficiency and temporal resolution in 3D fMRI.
    Hu Y; Glover GH
    Magn Reson Med; 2006 May; 55(5):1106-13. PubMed ID: 16598724
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Time-resolved 3D pulmonary perfusion MRI: comparison of different k-space acquisition strategies at 1.5 and 3 T.
    Attenberger UI; Ingrisch M; Dietrich O; Herrmann K; Nikolaou K; Reiser MF; Schönberg SO; Fink C
    Invest Radiol; 2009 Sep; 44(9):525-31. PubMed ID: 19652608
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional MRI with an undersampled spherical shells trajectory.
    Shu Y; Riederer SJ; Bernstein MA
    Magn Reson Med; 2006 Sep; 56(3):553-62. PubMed ID: 16894580
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Increasing spatial coverage for high-resolution functional MRI.
    Hu Y; Glover GH
    Magn Reson Med; 2009 Mar; 61(3):716-22. PubMed ID: 19097247
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Parallel imaging with 3D TPI trajectory: SNR and acceleration benefits.
    Qian Y; Stenger VA; Boada FE
    Magn Reson Imaging; 2009 Jun; 27(5):656-63. PubMed ID: 19110392
    [TBL] [Abstract][Full Text] [Related]  

  • 6. k-t GRAPPA: a k-space implementation for dynamic MRI with high reduction factor.
    Huang F; Akao J; Vijayakumar S; Duensing GR; Limkeman M
    Magn Reson Med; 2005 Nov; 54(5):1172-84. PubMed ID: 16193468
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid 3D radial multi-echo functional magnetic resonance imaging.
    Lee GR; Griswold MA; Tkach JA
    Neuroimage; 2010 Oct; 52(4):1428-43. PubMed ID: 20452436
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A dual K-space UNFOLD method for 3D functional brain imaging: A preliminary study.
    Kim SH; Kang CK
    Magn Reson Imaging; 2016 Feb; 34(2):120-6. PubMed ID: 26597831
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 3D multi-slab diffusion-weighted readout-segmented EPI with real-time cardiac-reordered K-space acquisition.
    Frost R; Miller KL; Tijssen RH; Porter DA; Jezzard P
    Magn Reson Med; 2014 Dec; 72(6):1565-79. PubMed ID: 24347093
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Combo acquisitions: balancing scan time reduction and image quality.
    Mekle R; Wu EX; Meckel S; Wetzel SG; Scheffler K
    Magn Reson Med; 2006 May; 55(5):1093-105. PubMed ID: 16598731
    [TBL] [Abstract][Full Text] [Related]  

  • 11. SNR enhancement in radial SSFP imaging using partial k-space averaging.
    Winkelmann S; Schaeffter T; Eggers H; Doessel O
    IEEE Trans Med Imaging; 2005 Feb; 24(2):254-62. PubMed ID: 15707251
    [TBL] [Abstract][Full Text] [Related]  

  • 12. SNR phase order k-space encoding (SPOKE).
    Paley MN; Wild JM; Lee KJ; Griffiths PD; Whitby EH
    Magn Reson Imaging; 2007 Dec; 25(10):1402-8. PubMed ID: 17566683
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Viewing the effective k-space coverage of MR images: phantom experiments with fast Fourier transform.
    Menke J; Helms G; Larsen J
    Magn Reson Imaging; 2010 Jan; 28(1):87-94. PubMed ID: 19553053
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling.
    Rahmer J; Börnert P; Groen J; Bos C
    Magn Reson Med; 2006 May; 55(5):1075-82. PubMed ID: 16538604
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 2D partially parallel imaging with k-space surrounding neighbors-based data reconstruction.
    Wang Z; Fernández-Seara MA
    Magn Reson Med; 2006 Dec; 56(6):1389-96. PubMed ID: 17063471
    [TBL] [Abstract][Full Text] [Related]  

  • 16. SNR-optimized phase-sensitive dual-acquisition turbo spin echo imaging: a fast alternative to FLAIR.
    Lee H; Park J
    Magn Reson Med; 2013 Jul; 70(1):106-16. PubMed ID: 22890939
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Parametric analysis of the spatial resolution and signal-to-noise ratio in super-resolved spatiotemporally encoded (SPEN) MRI.
    Ben-Eliezer N; Shrot Y; Frydman L; Sodickson DK
    Magn Reson Med; 2014 Aug; 72(2):418-29. PubMed ID: 24136737
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simultaneous acquisition of image and navigator slices using CAIPIRINHA for 4D MRI.
    Celicanin Z; Bieri O; Preiswerk F; Cattin P; Scheffler K; Santini F
    Magn Reson Med; 2015 Feb; 73(2):669-76. PubMed ID: 24604250
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Diffusion-weighted 3D multislab echo planar imaging for high signal-to-noise ratio efficiency and isotropic image resolution.
    Engström M; Skare S
    Magn Reson Med; 2013 Dec; 70(6):1507-14. PubMed ID: 23359357
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Generalized INverse imaging (GIN): ultrafast fMRI with physiological noise correction.
    Boyacioğlu R; Barth M
    Magn Reson Med; 2013 Oct; 70(4):962-71. PubMed ID: 23097342
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.