120 related articles for article (PubMed ID: 16598725)
21. An optimized 3D spoiled gradient recalled echo pulse sequence for hemorrhage assessment using inversion recovery and multiple echoes (3D SHINE) for carotid plaque imaging.
Zhu DC; Vu AT; Ota H; DeMarco JK
Magn Reson Med; 2010 Nov; 64(5):1341-51. PubMed ID: 20574968
[TBL] [Abstract][Full Text] [Related]
22. Accelerating non-contrast-enhanced MR angiography with inflow inversion recovery imaging by skipped phase encoding and edge deghosting (SPEED).
Chang Z; Xiang QS; Shen H; Yin FF
J Magn Reson Imaging; 2010 Mar; 31(3):757-65. PubMed ID: 20187224
[TBL] [Abstract][Full Text] [Related]
23. Effect of blood flow on double inversion recovery vessel wall MRI of the peripheral arteries: quantitation with T2 mapping and comparison with flow-insensitive T2-prepared inversion recovery imaging.
Brown R; Nguyen TD; Spincemaille P; Cham MD; Choi G; Winchester PA; Prince MR; Wang Y
Magn Reson Med; 2010 Mar; 63(3):736-44. PubMed ID: 20187182
[TBL] [Abstract][Full Text] [Related]
24. Fluid-attenuated inversion-recovery SSFP imaging.
Bangerter NK; Hargreaves BA; Gold GE; Stucker DT; Nishimura DG
J Magn Reson Imaging; 2006 Dec; 24(6):1426-31. PubMed ID: 17036358
[TBL] [Abstract][Full Text] [Related]
25. Fast 3D isotropic imaging of the aortic vessel wall by application of 2D spatially selective excitation and a new way of inversion recovery for black blood imaging.
Mooiweer R; Sbrizzi A; El Aidi H; Eikendal AL; Raaijmakers A; Visser F; van den Berg CA; Leiner T; Luijten PR; Hoogduin H
Magn Reson Med; 2016 Feb; 75(2):547-55. PubMed ID: 25761646
[TBL] [Abstract][Full Text] [Related]
26. Robust method for 3D arterial spin labeling in mice.
Chugh BP; Bishop J; Zhou YQ; Wu J; Henkelman RM; Sled JG
Magn Reson Med; 2012 Jul; 68(1):98-106. PubMed ID: 22102489
[TBL] [Abstract][Full Text] [Related]
27. Effective blood signal suppression using double inversion-recovery and slice reordering for multislice fast spin-echo MRI and its application in simultaneous proton density and T2 weighted imaging.
Kuribayashi H; Tessier JJ; Checkley DR; Wang YX; Hultin L; Waterton JC
J Magn Reson Imaging; 2004 Nov; 20(5):881-8. PubMed ID: 15503346
[TBL] [Abstract][Full Text] [Related]
28. DANTE-prepared pulse trains: a novel approach to motion-sensitized and motion-suppressed quantitative magnetic resonance imaging.
Li L; Miller KL; Jezzard P
Magn Reson Med; 2012 Nov; 68(5):1423-38. PubMed ID: 22246917
[TBL] [Abstract][Full Text] [Related]
29. Simultaneous parallel inclined readout image technique.
Paley MN; Lee KJ; Wild JM; Griffiths PD; Whitby EH
Magn Reson Imaging; 2006 Jun; 24(5):557-62. PubMed ID: 16735176
[TBL] [Abstract][Full Text] [Related]
30. Improved carotid intraplaque hemorrhage imaging using a slab-selective phase-sensitive inversion-recovery (SPI) sequence.
Wang J; Ferguson MS; Balu N; Yuan C; Hatsukami TS; Börnert P
Magn Reson Med; 2010 Nov; 64(5):1332-40. PubMed ID: 20597120
[TBL] [Abstract][Full Text] [Related]
31. Three-dimensional cerebral contrast-enhanced magnetic resonance venography at 3.0 Tesla: initial results using highly accelerated parallel acquisition.
Nael K; Fenchel M; Salamon N; Duckwiler GR; Laub G; Finn JP; Villablanca JP
Invest Radiol; 2006 Oct; 41(10):763-8. PubMed ID: 16971800
[TBL] [Abstract][Full Text] [Related]
32. High-resolution DTI of a localized volume using 3D single-shot diffusion-weighted STimulated echo-planar imaging (3D ss-DWSTEPI).
Jeong EK; Kim SE; Kholmovski EG; Parker DL
Magn Reson Med; 2006 Dec; 56(6):1173-81. PubMed ID: 17089367
[TBL] [Abstract][Full Text] [Related]
33. Fat suppression with short inversion time inversion-recovery and chemical-shift selective saturation: a dual STIR-CHESS combination prepulse for turbo spin echo pulse sequences.
Tanabe K; Nishikawa K; Sano T; Sakai O; Jara H
J Magn Reson Imaging; 2010 May; 31(5):1277-81. PubMed ID: 20432368
[TBL] [Abstract][Full Text] [Related]
34. Contrast-enhanced, three-dimensional, whole-brain, black-blood imaging: application to small brain metastases.
Park J; Kim EY
Magn Reson Med; 2010 Mar; 63(3):553-61. PubMed ID: 20187162
[TBL] [Abstract][Full Text] [Related]
35. Inversion recovery radial MRI with interleaved projection sets.
Peters DC; Botnar RM; Kissinger KV; Yeon SB; Appelbaum EA; Manning WJ
Magn Reson Med; 2006 May; 55(5):1150-6. PubMed ID: 16598720
[TBL] [Abstract][Full Text] [Related]
36. Vascular space occupancy weighted imaging with control of residual blood signal and higher contrast-to-noise ratio.
Wu WC; Buxton RB; Wong EC
IEEE Trans Med Imaging; 2007 Oct; 26(10):1319-27. PubMed ID: 17948723
[TBL] [Abstract][Full Text] [Related]
37. Multislice cardiac arterial spin labeling using improved myocardial perfusion quantification with simultaneously measured blood pool input function.
Campbell-Washburn AE; Zhang H; Siow BM; Price AN; Lythgoe MF; Ordidge RJ; Thomas DL
Magn Reson Med; 2013 Oct; 70(4):1125-36. PubMed ID: 23168945
[TBL] [Abstract][Full Text] [Related]
38. Design of flyback echo-planar readout gradients for magnetic resonance spectroscopic imaging.
Cunningham CH; Vigneron DB; Chen AP; Xu D; Nelson SJ; Hurd RE; Kelley DA; Pauly JM
Magn Reson Med; 2005 Nov; 54(5):1286-9. PubMed ID: 16187273
[TBL] [Abstract][Full Text] [Related]
39. Comparison of gated and non-gated fast multislice black-blood carotid imaging using rapid extended coverage and inflow/outflow saturation techniques.
Mani V; Itskovich VV; Aguiar SH; Mizsei G; Aguinaldo JG; Samber DD; Macaluso FM; Fayad ZA
J Magn Reson Imaging; 2005 Nov; 22(5):628-33. PubMed ID: 16215965
[TBL] [Abstract][Full Text] [Related]
40. DWI of the spinal cord with reduced FOV single-shot EPI.
Saritas EU; Cunningham CH; Lee JH; Han ET; Nishimura DG
Magn Reson Med; 2008 Aug; 60(2):468-73. PubMed ID: 18666126
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]