BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 16600615)

  • 1. Swan-Ganz bipolar pacing catheter entrapment in the tricuspid valve apparatus.
    Santini F; Messina A; Mazzucco A
    Eur J Cardiothorac Surg; 2006 May; 29(5):842. PubMed ID: 16600615
    [No Abstract]   [Full Text] [Related]  

  • 2. [Complications caused by a Swan-Ganz catheter. An inadvertent entrapment in the right atrium during cardiac surgery].
    Seitz W; Kaukemüller J; Frank G
    Anaesthesist; 1989 May; 38(5):259-61. PubMed ID: 2735522
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dislocation of a detached electrode from a pacing Swan-Ganz catheter in the hepatic vasculature.
    Aoyama H; Sunagawa H; Otsuka Y; Iizuka Y; Asaka K; Murayama T
    J Anesth; 2013 Apr; 27(2):318-9. PubMed ID: 23064680
    [No Abstract]   [Full Text] [Related]  

  • 4. Pulmonary artery catheter entrapment in cardiac surgery: a simple percutaneous solution.
    Divakaran V; Caldera A; Stephens J; Gonzalez R
    Cardiovasc Interv Ther; 2015 Oct; 30(4):382-4. PubMed ID: 25547257
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Entrapment of a Swan-Ganz-catheter in tricuspidal valve.
    Schregel W; Linge C; Melis W
    Acta Anaesthesiol Belg; 1991; 42(2):117-9. PubMed ID: 1927237
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Guidewire entrapment in a tricuspid valve apparatus.
    Chakraborty A; Donoo FA; Roy Chowdhury S; Saha A; Ganguly S; Rupert E
    J Cardiothorac Vasc Anesth; 2010 Oct; 24(5):898-9. PubMed ID: 20036155
    [No Abstract]   [Full Text] [Related]  

  • 7. Pulmonary Artery Catheter Knotted in the Tricuspid Valve Apparatus Requiring Surgery With Cardiopulmonary Bypass: A Case Report.
    Perez d'Empaire P; Derzi S; Latter D; Tousignant C
    A A Pract; 2019 Sep; 13(5):181-184. PubMed ID: 31162226
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bidirectional manipulation facilitating percutaneous retrieval of Swan-Ganz catheter entrapped in tricuspid valve apparatus.
    Khard A; Lefèvre T
    Catheter Cardiovasc Interv; 2008 Feb; 71(3):364-6. PubMed ID: 18288728
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transoesophageal echocardiography: a useful tool to diagnose entrapment of pulmonary artery catheter.
    Rupert E; Paul A; Mukherji J
    Anaesthesia; 2006 Jul; 61(7):702-4. PubMed ID: 16792618
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Right ventricular perforation caused by Swan-Ganz pacing catheter.
    Nagata T; Hirai Y; Wang Y
    Asian Cardiovasc Thorac Ann; 2016 Feb; 24(2):219. PubMed ID: 25033916
    [No Abstract]   [Full Text] [Related]  

  • 11. Entrapment of a Swan-Ganz catheter.
    Chen LC; Huang PH
    J Chin Med Assoc; 2007 May; 70(5):213-4. PubMed ID: 17524999
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Severe acute tricuspid regurgitation after the withdrawal of an entrapped pulmonary artery catheter.
    Rosemeier F; De Wet CJ; Hantler C; Jacobsohn E
    J Cardiothorac Vasc Anesth; 2006 Dec; 20(6):910-1. PubMed ID: 17138107
    [No Abstract]   [Full Text] [Related]  

  • 13. Severe Tricuspid Regurgitation After Percutaneous Removal of a Swan-Ganz Catheter Caught by Suture.
    Gennari M; Bartorelli AL; Polvani G; Muratori M; Ferrari C; Penza E; Arlati FG; Agrifoglio M
    Ann Thorac Surg; 2017 Sep; 104(3):e225-e226. PubMed ID: 28838512
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A rare complication of pulmonary artery catheterization during cardiac surgery: entrapment of pulmonary artery catheter around an intracardiac structure.
    De Hert SG; Boeckxstaens CJ; Vlaeminck RE; Gillis MR; Moens MM; Vermeyen KM
    Acta Anaesthesiol Belg; 1993; 44(2):53-6. PubMed ID: 8237296
    [No Abstract]   [Full Text] [Related]  

  • 15. Difficult flotation of a pulmonary artery catheter: echocardiographic diagnosis.
    Safwat AM
    J Clin Anesth; 2001 May; 13(3):239-40. PubMed ID: 11407337
    [No Abstract]   [Full Text] [Related]  

  • 16. Coil entrapment in the tricuspid valve apparatus requiring surgical removal: an unusual complication of transcatheter closure of patent ductus arteriosus.
    Fulwani MC; Vajifdar B; Tendolkar AG; Dalvi BV
    Indian Heart J; 1999; 51(1):77-9. PubMed ID: 10327785
    [No Abstract]   [Full Text] [Related]  

  • 17. An infrequent complication of Swan-Ganz catheters.
    Racionero MA; Prados C; Acitores I; Lazaro-Carrasco MT; Alvarez-Sala R
    J Cardiovasc Surg (Torino); 1995 Oct; 36(5):519-20. PubMed ID: 8522576
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Indications for Swan-Ganz catheterization.
    Hebert KA; Glancy DL
    Heart Dis Stroke; 1994; 3(4):196-200. PubMed ID: 7921663
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Percutaneous fluoroscopic removal of a knotted Swan-Ganz catheter in a patient with a persistent left-sided superior vena cava.
    Ranatunga D; Richardson M; Brooks D
    Australas Radiol; 2007 Apr; 51(2):182-5. PubMed ID: 17419868
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Infrequent complication of pulmonary artery catheterization: knot in a Swan-Ganz catheter].
    Núñez Lezama L; Pérez Torres MC; De Luis Navarro JC; de la Matta Martín M
    Rev Esp Anestesiol Reanim; 2002 Oct; 49(8):436-7. PubMed ID: 12455327
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.