These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

229 related articles for article (PubMed ID: 16601953)

  • 1. Silver(I)-selective electrode based on [Bz2Oxo4(18)dieneS4] tetrathia macrocyclic carrier.
    Singh AK; Saxena P
    Anal Bioanal Chem; 2006 May; 385(1):90-5. PubMed ID: 16601953
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A polystyrene based membrane electrode for cadmium(II) ions.
    Panwar A; Baniwal S; Sharma CL; Singh AK
    Fresenius J Anal Chem; 2000 Dec; 368(8):768-72. PubMed ID: 11227561
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Strontium(II)-selective electrode based on a macrocyclic tetraamide.
    Singh AK; Saxena P; Mehtab S; Gupta B
    Talanta; 2006 Apr; 69(2):521-6. PubMed ID: 18970598
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A polyvinylchloride-based cadmium ion-selective electrode using [Mo₂(OAc)₂(H₂-calix[4]arene)] as an electroactive material.
    Tyagi S; Agarwal H; Ikram S
    Water Sci Technol; 2010; 62(11):2510-8. PubMed ID: 21099036
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of electrochemical sensors for nano scale Tb(III) ion determination based on pendant macrocyclic ligands.
    Singh AK; Singh P; Banerjee S; Mehtab S
    Anal Chim Acta; 2009 Feb; 633(1):109-18. PubMed ID: 19110124
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of cerium ion by polymeric membrane and coated graphite electrode based on novel pendant armed macrocycle.
    Singh AK; Singh P
    Anal Chim Acta; 2010 Aug; 675(2):170-80. PubMed ID: 20800729
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 2,6-bis-methylsulfanyl-[1,3,5]thiadiazine-4-thione as a Ag+-selective ionophore.
    Mahajan RK; Sood P; Mahajan MP; Singh P
    Anal Sci; 2004 Oct; 20(10):1423-6. PubMed ID: 15524195
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cobalt(II)-selective membrane sensor based on a [Me2(13)dieneN4] macrocyclic cobalt complex.
    Singh AK; Saxena P; Mehtab S; Panwar A
    Anal Bioanal Chem; 2006 Aug; 385(7):1342-6. PubMed ID: 16794813
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of cobalt ions at nano-level based on newly synthesized pendant armed macrocycle by polymeric membrane and coated graphite electrode.
    Singh AK; Singh P; Bhattacharjee G
    Talanta; 2009 Dec; 80(2):685-93. PubMed ID: 19836538
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Nickel(II)-selective sensor based on dibenzo-18-crown-6 in PVC matrix.
    Gupta VK; Goyal RN; Agarwal S; Kumar P; Bachheti N
    Talanta; 2007 Feb; 71(2):795-800. PubMed ID: 19071376
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A highly selective thallium(I) electrode based on a thia substituted macrocyclic ionophore.
    Singh AK; Saxena P
    Talanta; 2005 May; 66(4):993-8. PubMed ID: 18970082
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new beryllium ion-selective membrane electrode based on dibenzo(perhydrotriazino)aza-14-crown-4 ether.
    Gupta VK; Singh AK; Mergu N
    Anal Chim Acta; 2012 Oct; 749():44-50. PubMed ID: 23036465
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Poly(vinyl chloride)-based macrocyclic membrane sensors for magnesium.
    Baniwal S; Chandra S; Panwar A; Singh AK
    Talanta; 1999 Oct; 50(3):499-508. PubMed ID: 18967740
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Chromium(III) selective membrane sensors based on Schiff bases as chelating ionophores.
    Singh AK; Gupta VK; Gupta B
    Anal Chim Acta; 2007 Feb; 585(1):171-8. PubMed ID: 17386662
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fabrication of novel coated pyrolytic graphite electrodes for the selective nano-level monitoring of Cd²⁺ ions in biological and environmental samples using polymeric membrane of newly synthesized macrocycle.
    Sahani MK; Singh AK; Jain AK; Upadhyay A; Kumar A; Singh UP; Narang S
    Anal Chim Acta; 2015 Feb; 860():51-60. PubMed ID: 25682247
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Coated-wire copper(II)-selective electrode based on phenylglyoxal-alpha-monoxime ionophore.
    Firooz AR; Mazloum M; Safari J; Amini MK
    Anal Bioanal Chem; 2002 Mar; 372(5-6):718-22. PubMed ID: 11941444
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An all-solid-state monohydrogen phosphate sensor based on a macrocyclic ionophore.
    Kumar P; Kim DM; Hyun MH; Shim YB
    Talanta; 2010 Sep; 82(4):1107-12. PubMed ID: 20801305
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Potentiometric determination of silver(I) by selective membrane electrode based on derivative of porphyrin.
    Mazloum Ardakani M; Dehghani H; Jalayer M; Zare HR
    Anal Sci; 2004 Dec; 20(12):1667-72. PubMed ID: 15636513
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A highly selective mercury electrode based on a diamine donor ligand.
    Gupta VK; Chandra S; Lang H
    Talanta; 2005 Apr; 66(3):575-80. PubMed ID: 18970023
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A highly selective and sensitive thorium(IV) PVC membrane electrode based on a dithio-tetraaza macrocyclic compound.
    Chandra S; Agarwal H; Singh CK
    Anal Sci; 2007 Apr; 23(4):469-73. PubMed ID: 17420554
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.