These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
181 related articles for article (PubMed ID: 16604596)
1. Simulation of germanium detector calibration using the Monte Carlo method: comparison between point and surface source models. Ródenas J; Burgos MC; Zarza I; Gallardo S Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):55-8. PubMed ID: 16604596 [TBL] [Abstract][Full Text] [Related]
2. Monte Carlo study of a 60Co calibration field of the Dosimetry Laboratory Seibersdorf. Hranitzky C; Stadtmann H Radiat Prot Dosimetry; 2007; 125(1-4):153-6. PubMed ID: 17337744 [TBL] [Abstract][Full Text] [Related]
3. Application of PENELOPE code to the efficiency calibration of coaxial germanium detectors. Jurado Vargas M; Guerra AL Appl Radiat Isot; 2006; 64(10-11):1319-22. PubMed ID: 16549348 [TBL] [Abstract][Full Text] [Related]
4. Nondestructive characterization of radioactive waste drums by gamma spectrometry: a Monte Carlo technique for efficiency calibration. Tzika F; Savidou A; Stamatelatos IE Health Phys; 2007 Nov; 93(5 Suppl):S174-9. PubMed ID: 18049246 [TBL] [Abstract][Full Text] [Related]
5. Software studies for germanium detectors data analysis. Pibida L; Hsieh E; Fuentes-Figueroa A; Hammond MM; Karam L Appl Radiat Isot; 2006; 64(10-11):1313-8. PubMed ID: 16564692 [TBL] [Abstract][Full Text] [Related]
6. Monte Carlo modelling of a simple accident dosemeter. Devine RT Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):486-8. PubMed ID: 16604683 [TBL] [Abstract][Full Text] [Related]
8. Experimental and MC determination of HPGe detector efficiency in the 40-2754 keV energy range for measuring point source geometry with the source-to-detector distance of 25 cm. Dryak P; Kovar P Appl Radiat Isot; 2006; 64(10-11):1346-9. PubMed ID: 16564693 [TBL] [Abstract][Full Text] [Related]
9. Electron spectra measurements and Monte Carlo calculations for a 60Co standardised hot particle source. Villarreal-Barajas JE; Bowler MG; Charles MW Radiat Prot Dosimetry; 2003; 104(2):113-9. PubMed ID: 12918788 [TBL] [Abstract][Full Text] [Related]
10. Calibration and background measurements with a tissue equivalent proportional counter. Autischer M; Beck P; Kindl P; Latocha M; Rollet S Radiat Prot Dosimetry; 2007; 125(1-4):429-32. PubMed ID: 17277328 [TBL] [Abstract][Full Text] [Related]
11. Monte Carlo method for gamma spectrometry based on GEANT4 toolkit: Efficiency calibration of BE6530 detector. Cebastien Joel GS; Maurice NM; Eric Jilbert NM; Ousmanou M; David S J Environ Radioact; 2018 Sep; 189():109-119. PubMed ID: 29653355 [TBL] [Abstract][Full Text] [Related]
12. Application of unfolding technique to HPGe detector using response functions calculated with the EGS4 Monte Carlo code. Chun KJ; Hah SH; Kim HM; Yoo GH J Radiat Res; 2006 Mar; 47(1):27-40. PubMed ID: 16571916 [TBL] [Abstract][Full Text] [Related]
13. Potential of modern technologies for improvement of in vivo calibration. Franck D; de Carlan L; Fisher H; Pierrat N; Schlagbauer M; Wahl W Radiat Prot Dosimetry; 2007; 125(1-4):438-43. PubMed ID: 17337736 [TBL] [Abstract][Full Text] [Related]
14. Benchmarking of Monte Carlo based shutdown dose rate calculations for applications to JET. Petrizzi L; Batistoni P; Fischer U; Loughlin M; Pereslavtsev P; Villari R Radiat Prot Dosimetry; 2005; 115(1-4):80-5. PubMed ID: 16381687 [TBL] [Abstract][Full Text] [Related]
15. Construction of 144, 565 keV and 5.0 MeV monoenergetic neutron calibration fields at JAERI. Tanimura Y; Yoshizawa M; Saegusa J; Fujii K; Shimizu S; Yoshida M; Shibata Y; Uritani A; Kudo K Radiat Prot Dosimetry; 2004; 110(1-4):85-9. PubMed ID: 15353627 [TBL] [Abstract][Full Text] [Related]
16. Simulation and measurements of the response of an air ionisation chamber exposed to a mixed high-energy radiation field. Vincke H; Forkel-Wirth D; Perrin D; Theis C Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):380-6. PubMed ID: 16604664 [TBL] [Abstract][Full Text] [Related]
18. Monte Carlo evaluations and the source normalisation problem. Neuhold P Radiat Prot Dosimetry; 2005; 115(1-4):268-70. PubMed ID: 16381726 [TBL] [Abstract][Full Text] [Related]
19. Experimental HPGe coaxial detector response and efficiency compared to Monte Carlo simulations. Maidana NL; Vanin VR; García-Alvarez JA; Hermida-López M; Brualla L Appl Radiat Isot; 2016 Feb; 108():64-74. PubMed ID: 26704703 [TBL] [Abstract][Full Text] [Related]
20. MCNP SIMULATION OF THE HP(10) ENERGY RESPONSE OF A BRAZILIAN TLD ALBEDO NEUTRON INDIVIDUAL DOSEMETER, FROM THERMAL TO 20 MeV. Freitas BM; Martins MM; Pereira WW; da Silva AX; Mauricio CL Radiat Prot Dosimetry; 2016 Sep; 170(1-4):350-3. PubMed ID: 26276807 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]