1. Dose distribution around a needle-like anode X-ray tube: dye-film vs. planar thermoluminescent detectors.
Budzanowski M; Olko P; Marczewska B; Czopyk L; Slapa M; Stras W; Traczyk M; Talejko M
Radiat Prot Dosimetry; 2006; 120(1-4):117-20. PubMed ID: 16614087
[TBL] [Abstract][Full Text] [Related]
2. Two-dimensional thermoluminescence dosimetry using planar detectors and a TL reader with CCD camera readout.
Marczewska B; Bilski P; Czopyk L; Olko P; Waligórski MP; Zapotoczny S
Radiat Prot Dosimetry; 2006; 120(1-4):129-32. PubMed ID: 16614089
[TBL] [Abstract][Full Text] [Related]
3. New 2-D dosimetric technique for radiotherapy based on planar thermoluminescent detectors.
Olko P; Marczewska B; Czopyk L; Czermak MA; Klosowski M; Waligórski MP
Radiat Prot Dosimetry; 2006; 118(2):213-8. PubMed ID: 16735573
[TBL] [Abstract][Full Text] [Related]
4. Tissue-equivalent TL sheet dosimetry system for X- and gamma-ray dose mapping.
Nariyama N; Konnai A; Ohnishi S; Odano N; Yamaji A; Ozasa N; Ishikawa Y
Radiat Prot Dosimetry; 2006; 120(1-4):136-9. PubMed ID: 16614090
[TBL] [Abstract][Full Text] [Related]
5. A method for distinguishing between static and dynamic X-ray exposure of a personal TL-badge using the CCD camera TL reader.
Budzanowski M; Olko P; Golnik N
Radiat Prot Dosimetry; 2006; 119(1-4):259-62. PubMed ID: 16614092
[TBL] [Abstract][Full Text] [Related]
6. Identification of static exposure of standard dosimetric badge with thermoluminescent detectors.
Budzanowski M; Olko P; Kopeć R; Obryk B; Dzikiewicz-Sapiecha H; Siwicki R
Radiat Prot Dosimetry; 2007; 125(1-4):213-6. PubMed ID: 17038405
[TBL] [Abstract][Full Text] [Related]
7. Dosimetry of BNCT beams with novel thermoluminescent detectors.
Bilski P; Budzanowski M; Ochab E; Olko P; Czopyk Ł
Radiat Prot Dosimetry; 2004; 110(1-4):623-6. PubMed ID: 15353719
[TBL] [Abstract][Full Text] [Related]
8. Experimental determination of the dose deposition profile of a 90Sr beta source.
Gaza R; Bulur E; McKeever SW; Soares CG
Radiat Prot Dosimetry; 2006; 120(1-4):33-7. PubMed ID: 16644945
[TBL] [Abstract][Full Text] [Related]
9. The use of TLD and Gafchromic film to assure submillimeter accuracy for image-guided radiosurgery.
Ho AK; Gibbs IC; Chang SD; Main B; Adler JR
Med Dosim; 2008; 33(1):36-41. PubMed ID: 18262121
[TBL] [Abstract][Full Text] [Related]
10. Absorbed dose measurements of a handheld 50 kVP X-ray source in water with thermoluminescence dosemeters.
Soares C; Drupieski C; Wingert B; Pritchett G; Pagonis V; O'Brien M; Sliski A; Bilski P; Olko P
Radiat Prot Dosimetry; 2006; 120(1-4):78-82. PubMed ID: 16735571
[TBL] [Abstract][Full Text] [Related]
11. Electron dose radiation response of dyed PMMA detectors developed at IPEN.
Galante AM; Campos LL
Radiat Prot Dosimetry; 2006; 120(1-4):113-6. PubMed ID: 16644957
[TBL] [Abstract][Full Text] [Related]
12. On the relationship between dose-, energy- and LET-response of thermoluminescent detectors.
Olko P; Bilski P; El-Faramawy NA; Göksu HY; Kim JL; Kopec R; Waligórski MP
Radiat Prot Dosimetry; 2006; 119(1-4):15-22. PubMed ID: 16644968
[TBL] [Abstract][Full Text] [Related]
13. On the dose response of some CVD diamond thermoluminescent detectors.
Marczewska B; Bilski P; Olko P; Nesladek M; Rebisz M; Guerrero MJ
Radiat Prot Dosimetry; 2006; 119(1-4):319-22. PubMed ID: 16644953
[TBL] [Abstract][Full Text] [Related]
14. A fibre optic scintillator dosemeter for absorbed dose measurements of low-energy X-ray-emitting brachytherapy sources.
Sliski A; Soares C; Mitch MG
Radiat Prot Dosimetry; 2006; 120(1-4):24-7. PubMed ID: 16782747
[TBL] [Abstract][Full Text] [Related]
15. Validation testing of ANSI/IEEE n42.49 standard requirements for personal emergency radiation detectors.
Pibida L; Minniti R; O'Brien M
Health Phys; 2010 Apr; 98(4):597-602. PubMed ID: 20220367
[TBL] [Abstract][Full Text] [Related]
16. TL detectors for gamma ray dose measurements in criticality accidents.
Miljanić S; Zorko B; Gregori B; Knezević Z
Radiat Prot Dosimetry; 2007; 125(1-4):318-22. PubMed ID: 17369267
[TBL] [Abstract][Full Text] [Related]
17. Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams.
Rampado O; Garelli E; Deagostini S; Ropolo R
Phys Med Biol; 2006 Jun; 51(11):2871-81. PubMed ID: 16723772
[TBL] [Abstract][Full Text] [Related]
18. Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.
Ginjaume M; Pérez S; Ortega X; Duch MA
Radiat Prot Dosimetry; 2006; 120(1-4):316-20. PubMed ID: 16644980
[TBL] [Abstract][Full Text] [Related]
19. Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for X-rays and their application to Monte Carlo simulations of dosemeter response.
Hranitzky C; Stadtmann H; Olko P
Radiat Prot Dosimetry; 2006; 119(1-4):483-6. PubMed ID: 16822775
[TBL] [Abstract][Full Text] [Related]
20. Thermoluminescence properties of CVD diamond for clinical dosimetry use.
Benabdesselam M; Serrano B; Iacconi P; Wrobel F; Lapraz D; Herault J; Butler JE
Radiat Prot Dosimetry; 2006; 120(1-4):87-90. PubMed ID: 16565201
[TBL] [Abstract][Full Text] [Related]