These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 16618845)

  • 1. What happens if you delay scanning Digora phosphor storage plates (PSPs) for up to 4 hours?
    Martins MG; Whaites EJ; Ambrosano GM; Haiter Neto F
    Dentomaxillofac Radiol; 2006 May; 35(3):143-6. PubMed ID: 16618845
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analysis of digital images acquired using different phosphor storage plates (PSPs) subjected to varying reading times and storage conditions.
    Martins MG; Haiter Neto F; Whaites EJ
    Dentomaxillofac Radiol; 2003 May; 32(3):186-90. PubMed ID: 12917285
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of delayed scanning of storage phosphor plates.
    Akdeniz BG; Gröndahl HG; Kose T
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2005 May; 99(5):603-7. PubMed ID: 15829885
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of delayed scanning of storage phosphor plates on occlusal caries detection.
    Sogur E; Baksi BG; Mert A
    Dentomaxillofac Radiol; 2012 May; 41(4):309-15. PubMed ID: 22282506
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Degradation of storage phosphor images due to scanning delay.
    Akdeniz BG; Gröndahl HG
    Dentomaxillofac Radiol; 2006 Mar; 35(2):74-7. PubMed ID: 16549432
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates.
    Eskandarloo A; Yousefi A; Soheili S; Ghazikhanloo K; Amini P; Mohammadpoor H
    Open Dent J; 2017; 11():690-700. PubMed ID: 29430262
    [TBL] [Abstract][Full Text] [Related]  

  • 7. How many times can we use a phosphor plate? A preliminary study.
    Ergün S; Güneri P; Ilgüy D; Ilgüy M; Boyacioglu H
    Dentomaxillofac Radiol; 2009 Jan; 38(1):42-7. PubMed ID: 19114423
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quality of digital pre-implant tomography: comparison of film-screen images with storage phosphor images at normal and low dose.
    Ekestubbe A; Gröndahl HG; Molander B
    Dentomaxillofac Radiol; 2003 Sep; 32(5):322-6. PubMed ID: 14709608
    [TBL] [Abstract][Full Text] [Related]  

  • 9. How does signal fade on photo-stimulable storage phosphor imaging plates when scanned with a delay and what is the effect on image quality?
    Ang DB; Angelopoulos C; Katz JO
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2006 Nov; 102(5):673-9. PubMed ID: 17052646
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reproducibility of pixel values for two photostimulable phosphor plates in consecutive standardized scannings.
    Freitas P; Yaedú RY; Rubira-Bullen IR; Escarpinati M; Vieira MC; Schiabel H; Lauris JR
    Braz Oral Res; 2006; 20(3):207-13. PubMed ID: 17119702
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of linear measurements made from storage phosphor and dental radiographs.
    Conover GL; Hildebolt CF; Yokoyama-Crothers N
    Dentomaxillofac Radiol; 1996 Nov; 25(5):268-73. PubMed ID: 9161181
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An ex vivo comparison of conventional and digital radiography for perceived image quality of root fillings.
    Akdeniz BG; Soğur E
    Int Endod J; 2005 Jun; 38(6):397-401. PubMed ID: 15910475
    [TBL] [Abstract][Full Text] [Related]  

  • 13. On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems.
    Borg E; Gröndahl HG
    Dentomaxillofac Radiol; 1996 Apr; 25(2):82-8. PubMed ID: 9446978
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative study of two digital radiographic storage phosphor systems.
    Oliveira AE; de Almeida SM; Paganini GA; Haiter Neto F; Bóscolo FN
    Braz Dent J; 2000; 11(2):111-6. PubMed ID: 11210259
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of the deterioration of photostimulable phosphor plates.
    Souza-Pinto GN; Santaella GM; Coli AA; Oenning AC; Haiter-Neto F
    Dentomaxillofac Radiol; 2020 Sep; 49(6):20190500. PubMed ID: 32302219
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Radiopacity of resin-based materials measured in film radiographs and storage phosphor plate (Digora).
    Sabbagh J; Vreven J; Leloup G
    Oper Dent; 2004; 29(6):677-84. PubMed ID: 15646224
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of standard and task-specific enhancement of Digora storage phosphor images for approximal caries diagnosis.
    Møystad A; Svanaes DB; van der Stelt PF; Gröndahl HG; Wenzel A; van Ginkel FC; Kullendorff B; Hintze H; Larheim TA
    Dentomaxillofac Radiol; 2003 Nov; 32(6):390-6. PubMed ID: 15070842
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detection of approximal caries with a storage phosphor system. A comparison of enhanced digital images with dental X-ray film.
    Møystad A; Svanaes DB; Risnes S; Larheim TA; Gröndahl HG
    Dentomaxillofac Radiol; 1996 Sep; 25(4):202-6. PubMed ID: 9084274
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Image quality in partially erased DenOptix storage phosphor plates.
    Lopes SL; Cruz AD; Ferreira RI; Bóscolo FN; Almeida SM
    Braz Oral Res; 2008; 22(1):78-83. PubMed ID: 18425250
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of caries detection with four storage phosphor systems and E-speed radiographs.
    Hintze H; Wenzel A; Frydenberg M
    Dentomaxillofac Radiol; 2002 May; 31(3):170-5. PubMed ID: 12058264
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.