These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

194 related articles for article (PubMed ID: 16635998)

  • 1. Patient Alert to detect ICD lead failure: efficacy, limitations, and implications for future algorithms.
    Vollmann D; Erdogan A; Himmrich E; Neuzner J; Becker D; Unterberg-Buchwald C; Sperzel J
    Europace; 2006 May; 8(5):371-6. PubMed ID: 16635998
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Patient alert in implantable cardioverter defibrillators: toy or tool?
    Becker R; Ruf-Richter J; Senges-Becker JC; Bauer A; Weretka S; Voss F; Katus HA; Schoels W
    J Am Coll Cardiol; 2004 Jul; 44(1):95-8. PubMed ID: 15234415
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An algorithm to predict implantable cardioverter-defibrillator lead failure.
    Gunderson BD; Patel AS; Bounds CA; Shepard RK; Wood MA; Ellenbogen KA
    J Am Coll Cardiol; 2004 Nov; 44(9):1898-902. PubMed ID: 15519026
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure.
    Spencker S; Coban N; Koch L; Schirdewan A; Müller D
    Europace; 2009 Apr; 11(4):483-8. PubMed ID: 19103654
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automatic identification of clinical lead dysfunctions.
    Gunderson BD; Patel AS; Bounds CA; Ellenbogen KA
    Pacing Clin Electrophysiol; 2005 Jan; 28 Suppl 1():S63-7. PubMed ID: 15683528
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Limitation of programmed alerts to predict ICD lead failures.
    Vlay SC
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):554-5. PubMed ID: 19335870
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Downloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Stadler RW; Gillberg JM; Patel AS; Ellenbogen KA
    Circulation; 2008 Nov; 118(21):2122-9. PubMed ID: 18981299
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multiple ICD discharges associated with lead fracture without triggering of high impedance alert.
    Donaldson DM; Singh JP; Heist EK; Mela T; Ruskin JN; Das S
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):543-6. PubMed ID: 19335867
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Downloadable software algorithm reduces inappropriate shocks caused by implantable cardioverter-defibrillator lead fractures: a prospective study.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Sachanandani H; Ellenbogen KA
    Circulation; 2010 Oct; 122(15):1449-55. PubMed ID: 20876433
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical utility of intrathoracic impedance monitoring to alert patients with an implanted device of deteriorating chronic heart failure.
    Vollmann D; Nägele H; Schauerte P; Wiegand U; Butter C; Zanotto G; Quesada A; Guthmann A; Hill MR; Lamp B;
    Eur Heart J; 2007 Aug; 28(15):1835-40. PubMed ID: 17309902
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automatic impedance monitoring and patient alert feature in implantable cardioverter defibrillators: being alert for the unexpected!
    Duru F; Luechinger R; Scharf C; Brunckhorst C
    J Cardiovasc Electrophysiol; 2005 Apr; 16(4):444-8. PubMed ID: 15828892
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert.
    Gelder RN; Gunderson BD
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Remote implantable cardioverter defibrillator monitoring in a Brugada syndrome population.
    Sacher F; Probst V; Bessouet M; Wright M; Maluski A; Abbey S; Bordachar P; Deplagne A; Ploux S; Lande G; Jaïs P; Hocini M; Haïssaguerre M; Le Marec H; Clémenty J
    Europace; 2009 Apr; 11(4):489-94. PubMed ID: 19218576
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A prospective experience with the lead integrity alert: new certainties and new uncertainties.
    Koenig T; Gardiwal A; Oswald H; Klein G
    Europace; 2009 Nov; 11(11):1549-51. PubMed ID: 19666640
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Towards eradication of inappropriate therapies for ICD lead failure by combining comprehensive remote monitoring and lead noise alerts.
    Ploux S; Swerdlow CD; Strik M; Welte N; Klotz N; Ritter P; Haïssaguerre M; Bordachar P
    J Cardiovasc Electrophysiol; 2018 Aug; 29(8):1125-1134. PubMed ID: 29858871
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead.
    Kallinen LM; Hauser RG; Lee KW; Almquist AK; Katsiyiannis WT; Tang CY; Melby DP; Gornick CC
    Heart Rhythm; 2008 Jun; 5(6):775-9. PubMed ID: 18534361
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical performance of implantable cardioverter-defibrillator lead monitoring diagnostics.
    Poole JE; Swerdlow CD; Tarakji KG; Mittal S; Ellenbogen KA; Greenspon AJ; Kennergren C; Philbert BT; Moore J; Jones RC; Schaller RD; Hansalia R; Simmers T; Mihalcz A; DeBus B; Lexcen DR; Gunderson B; Wilkoff BL
    Heart Rhythm; 2022 Mar; 19(3):363-371. PubMed ID: 34767985
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Acute evaluation of transthoracic impedance vectors using ICD leads.
    Gottfridsson C; Daum D; Kennergren C; Ramuzat A; Willems R; Edvardsson N
    Pacing Clin Electrophysiol; 2009 Jun; 32(6):762-71. PubMed ID: 19545339
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lead Integrity Alert Is Useful for Assessment of Performance of Biotronik Linox Leads.
    Steinberg C; Padfield GJ; Hahn E; Flavelle S; McILROY C; VAN Bremen O; Yeung-Lai-Wah JA; Kerr CR; Deyell MW; Tung SK; Andrade JG; Bennett MT; Bashir JG; Krahn AD; Chakrabarti S
    J Cardiovasc Electrophysiol; 2015 Dec; 26(12):1340-5. PubMed ID: 26471861
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.