These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 16639399)

  • 1. [Effect of vibration caused by time-varying magnetic fields on diffusion-weighted MRI].
    Ogura A; Maeda F; Miyai A; Hayashi K; Hongoh T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2006 Apr; 62(4):565-9. PubMed ID: 16639399
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new phantom using polyethylene glycol as an apparent diffusion coefficient standard for MR imaging.
    Matsuya R; Kuroda M; Matsumoto Y; Kato H; Matsuzaki H; Asaumi J; Murakami J; Katashima K; Ashida M; Sasaki T; Sei T; Himei K; Katsui K; Katayama N; Takemoto M; Kanazawa S; Mimura S; Oono S; Kitayama T; Tahara S; Inamura K
    Int J Oncol; 2009 Oct; 35(4):893-900. PubMed ID: 19724927
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diffusion-weighted MRI of the lung at 3T evaluated using echo-planar-based and single-shot turbo spin-echo-based acquisition techniques for radiotherapy applications.
    Tyagi N; Cloutier M; Zakian K; Deasy JO; Hunt M; Rimner A
    J Appl Clin Med Phys; 2019 Jan; 20(1):284-292. PubMed ID: 30421496
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An acetone-based phantom for quantitative diffusion MRI.
    Wang X; Reeder SB; Hernando D
    J Magn Reson Imaging; 2017 Dec; 46(6):1683-1692. PubMed ID: 28432796
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Evaluation of Imaging Quality and ADC for the Tetrahedral Gradients of Diffusion Weighted Imaging].
    Yamaguchi N; Ogura A; Hayashi N; Koyama D; Osakabe K; Hatano I
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2015 Jul; 71(7):595-604. PubMed ID: 26194433
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Apparent diffusion coefficient measurements on a novel diffusion weighted MRI phantom utilizing EPI and HASTE sequences.
    Kalaitzakis G; Boursianis T; Gourzoulidis G; Gourtsoyianni S; Lymperopoulou G; Marias K; Karantanas A; Maris TG
    Phys Med; 2020 May; 73():179-189. PubMed ID: 32371141
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Image quality assessment of single-shot turbo spin echo diffusion-weighted imaging with parallel imaging technique: a phantom study.
    Yoshida T; Urikura A; Shirata K; Nakaya Y; Terashima S; Hosokawa Y
    Br J Radiol; 2016 Sep; 89(1065):20160512. PubMed ID: 27452269
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Four-dimensional diffusion-weighted MR imaging (4D-DWI): a feasibility study.
    Liu Y; Zhong X; Czito BG; Palta M; Bashir MR; Dale BM; Yin FF; Cai J
    Med Phys; 2017 Feb; 44(2):397-406. PubMed ID: 28121369
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Changes in the ADC of diffusion-weighted MRI with the oscillating gradient spin-echo (OGSE) sequence due to differences in substrate viscosities.
    Maekawa T; Hori M; Murata K; Feiweier T; Fukunaga I; Andica C; Hagiwara A; Kamagata K; Koshino S; Abe O; Aoki S
    Jpn J Radiol; 2018 Jul; 36(7):415-420. PubMed ID: 29700795
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A body-sized phantom for evaluation of diffusion-weighted MRI data using conventional, readout-segmented, and zoomed echo-planar sequences.
    Ihalainen T; Kuusela L; Soikkeli M; Lantto E; Ovissi A; Sipilä O
    Acta Radiol; 2016 Aug; 57(8):947-54. PubMed ID: 26543056
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of an MRI phantom for diffusion-weighted imaging with independent adjustment of apparent diffusion coefficient values and T2 relaxation times.
    Gatidis S; Schmidt H; Martirosian P; Schwenzer NF
    Magn Reson Med; 2014 Aug; 72(2):459-63. PubMed ID: 24123316
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reduction of vibration-induced signal loss by matching mechanical vibrational states: Application in high b-value diffusion-weighted MRS.
    Weidlich D; Zamskiy M; Maeder M; Ruschke S; Marburg S; Karampinos DC
    Magn Reson Med; 2020 Jul; 84(1):39-51. PubMed ID: 31872934
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Technical Note: A safe, cheap, and easy-to-use isotropic diffusion MRI phantom for clinical and multicenter studies.
    Pullens P; Bladt P; Sijbers J; Maas AI; Parizel PM
    Med Phys; 2017 Mar; 44(3):1063-1070. PubMed ID: 28079257
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Effect of Slice Thickness for Apparent Diffusion Coefficient Measurement of Mass].
    Asai A; Ogura A; Sotome H; Fuju A
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2018; 74(8):805-809. PubMed ID: 30122745
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of tumor morphology on diffusion-weighted (DWI) breast MRI: Diagnostic value of reduced field of view DWI.
    Barentsz MW; Taviani V; Chang JM; Ikeda DM; Miyake KK; Banerjee S; van den Bosch MA; Hargreaves BA; Daniel BL
    J Magn Reson Imaging; 2015 Dec; 42(6):1656-65. PubMed ID: 25914178
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A phantom for diffusion-weighted MRI (DW-MRI).
    Lavdas I; Behan KC; Papadaki A; McRobbie DW; Aboagye EO
    J Magn Reson Imaging; 2013 Jul; 38(1):173-9. PubMed ID: 23576443
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dependence of apparent diffusion coefficient measurement on diffusion gradient direction and spatial position - A quality assurance intercomparison study of forty-four scanners for quantitative diffusion-weighted imaging.
    Fedeli L; Belli G; Ciccarone A; Coniglio A; Esposito M; Giannelli M; Mazzoni LN; Nocetti L; Sghedoni R; Tarducci R; Altabella L; Belligotti E; Benelli M; Betti M; Caivano R; Carni' M; Chiappiniello A; Cimolai S; Cretti F; Fulcheri C; Gasperi C; Giacometti M; Levrero F; Lizio D; Maieron M; Marzi S; Mascaro L; Mazzocchi S; Meliado' G; Morzenti S; Noferini L; Oberhofer N; Quattrocchi MG; Ricci A; Taddeucci A; Tenori L; Luchinat C; Gobbi G; Gori C; Busoni S;
    Phys Med; 2018 Nov; 55():135-141. PubMed ID: 30342982
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of imaging parameters on the accuracy of apparent diffusion coefficient and optimization strategies.
    Celik A
    Diagn Interv Radiol; 2016; 22(1):101-7. PubMed ID: 26573977
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bilateral diffusion-weighted MR imaging of breast tumors with submillimeter resolution using readout-segmented echo-planar imaging at 7 T.
    Bogner W; Pinker K; Zaric O; Baltzer P; Minarikova L; Porter D; Bago-Horvath Z; Dubsky P; Helbich TH; Trattnig S; Gruber S
    Radiology; 2015 Jan; 274(1):74-84. PubMed ID: 25341078
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Apparent diffusion coefficient-dependent voxelwise computed diffusion-weighted imaging: An approach for improving SNR and reducing T2 shine-through effects.
    Gatidis S; Schmidt H; Martirosian P; Nikolaou K; Schwenzer NF
    J Magn Reson Imaging; 2016 Apr; 43(4):824-32. PubMed ID: 26348708
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.