These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
210 related articles for article (PubMed ID: 16639688)
41. Percutaneous ventricular assist device support during off-pump surgical coronary revascularization. Gregoric ID; Poglajen G; Span M; Frazier OH; Loyalka P; Kar B Ann Thorac Surg; 2008 Aug; 86(2):637-9. PubMed ID: 18640347 [TBL] [Abstract][Full Text] [Related]
42. [Nursing care of the patient with cardiac shock undergoing intra-aortic balloon pumping]. Inatomi K; Oda Y; Kudo H; Ohata Y; Harada F Kango Gijutsu; 1984 May; 30(7):912-8. PubMed ID: 6563142 [No Abstract] [Full Text] [Related]
43. [Counterpulsation using an intra-aortic balloon following cardiac surgery]. Bédard P; Akyurekli Y; Keon WJ Union Med Can; 1974 Oct; 103(10):1759-62. PubMed ID: 4446124 [No Abstract] [Full Text] [Related]
44. Mechanical circulatory support for acute cardiac failure in children: the options available. Collison SP; Dagar KS Indian Heart J; 2006; 58(4):345-9. PubMed ID: 19039153 [No Abstract] [Full Text] [Related]
45. [Left ventricular assist devices in the catheterisation laboratory]. Boughalem K; Teiger E Ann Cardiol Angeiol (Paris); 2007 Dec; 56(6):257-62. PubMed ID: 17988644 [TBL] [Abstract][Full Text] [Related]
46. [Effect and limitation of mechanical circulatory assistance for acute right ventricular infarction, with special reference to the pulmonary artery balloon pumping]. Shiono M Nihon Kyobu Geka Gakkai Zasshi; 1983 Oct; 31(10):1527-36. PubMed ID: 6655308 [No Abstract] [Full Text] [Related]
47. Use of the percutaneous left ventricular assist device in patients with severe refractory cardiogenic shock as a bridge to long-term left ventricular assist device implantation. Idelchik GM; Simpson L; Civitello AB; Loyalka P; Gregoric ID; Delgado R; Kar B J Heart Lung Transplant; 2008 Jan; 27(1):106-11. PubMed ID: 18187095 [TBL] [Abstract][Full Text] [Related]
48. [Cardiogenic shock caused by pulmonary gas embolism with cardiac arrest. Resuscitation]. Oprişoni V; Ene V; Hudiţeanu D Chirurgia (1951); 1974 Jan; 23(1):83-9. PubMed ID: 4819819 [No Abstract] [Full Text] [Related]
49. Implantation of CardioWest total artificial heart for irreversible acute myocardial infarction shock. Morshuis M; Reiss N; Arusoglu L; Tenderich G; Körfer R; El-Banayosy A Heart Surg Forum; 2007; 10(4):E251-6. PubMed ID: 17525048 [TBL] [Abstract][Full Text] [Related]
51. Use of extracorporeal membrane oxygenation for mechanical circulatory support in a patient with 5-fluorouracil induced acute heart failure. Rateesh S; Shekar K; Naidoo R; Mittal D; Bhaskar B Circ Heart Fail; 2015 Mar; 8(2):381-3. PubMed ID: 25783948 [No Abstract] [Full Text] [Related]
52. Aggressive management of acute myocardial infarction: successful outcome in an older patient with cardiogenic shock. Tsao YT; Wu CJ; Lin SL; Liu CP; Tak T Singapore Med J; 2007 Apr; 48(4):350-3. PubMed ID: 17384884 [TBL] [Abstract][Full Text] [Related]
53. Extracorporeal membrane oxygenation with a poly-methylpentene oxygenator (Quadrox D). The experience of a single Italian centre in adult patients with refractory cardiogenic shock. Formica F; Avalli L; Martino A; Maggioni E; Muratore M; Ferro O; Pesenti A; Paolini G ASAIO J; 2008; 54(1):89-94. PubMed ID: 18204321 [TBL] [Abstract][Full Text] [Related]
54. Usefulness of intra-aortic balloon pump counterpulsation in patients with cardiogenic shock from acute myocardial infarction. Cheng JM; Valk SD; den Uil CA; van der Ent M; Lagrand WK; van de Sande M; van Domburg RT; Simoons ML Am J Cardiol; 2009 Aug; 104(3):327-32. PubMed ID: 19616662 [TBL] [Abstract][Full Text] [Related]
55. Acute myocardial infarction complicated by cardiogenic shock: role of mechanical circulatory support. Aggarwal S; Slaughter MS Expert Rev Cardiovasc Ther; 2008 Oct; 6(9):1223-35. PubMed ID: 18939910 [TBL] [Abstract][Full Text] [Related]
56. Percutaneous intra-aortic balloon: use in Iowa. Phillips SJ; Brown TM; Gordon DF; Iannone L; Kongtahworn C; Beshany SE; Zeff RH J Iowa Med Soc; 1980 Dec; 70(12):503-6. PubMed ID: 7441029 [No Abstract] [Full Text] [Related]
57. Right ventricular infarction during a lung lobectomy in a patient with chronic obstructive pulmonary disease: report of a case. Chen F; Itoi S; Yoshimura T; Ueno T; Nakai M; Chihara K Surg Today; 2003; 33(10):758-60. PubMed ID: 14513324 [TBL] [Abstract][Full Text] [Related]
58. [Perioperative management of life-threatening intra-abdominal bleeding with intra-aortic balloon occlusion catheter]. Tsutsumi N; Masuda Y; Imaizumi H; Chaki R; Nakamura M; Kazama K; Satoh M; Namiki A Masui; 2001 Jan; 50(1):46-9. PubMed ID: 11211750 [TBL] [Abstract][Full Text] [Related]
59. Morbidity in video-assisted thoracoscopic lobectomy for clinical stage I non-small cell lung cancer: is VATS lobectomy really safe? Kawachi R; Tsukada H; Nakazato Y; Takei H; Koshi-ishi Y; Goya T Thorac Cardiovasc Surg; 2009 Apr; 57(3):156-9. PubMed ID: 19330753 [TBL] [Abstract][Full Text] [Related]
60. Outcomes and long-term quality-of-life of patients supported by extracorporeal membrane oxygenation for refractory cardiogenic shock. Combes A; Leprince P; Luyt CE; Bonnet N; Trouillet JL; Léger P; Pavie A; Chastre J Crit Care Med; 2008 May; 36(5):1404-11. PubMed ID: 18434909 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]