BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 16643231)

  • 1. Practical sources of error in measuring pulmonary artery occlusion pressure: a study in participants of a special intensivist training program of The Scandinavian Society of Anaesthesiology and Intensive Care Medicine (SSAI).
    Parviainen I; Jakob SM; Suistomaa M; Takala J;
    Acta Anaesthesiol Scand; 2006 May; 50(5):600-3. PubMed ID: 16643231
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study.
    Corley A; Barnett AG; Mullany D; Fraser JF
    Int J Nurs Stud; 2009 Oct; 46(10):1291-7. PubMed ID: 19423107
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Guideline development and education to insure accurate and consistent pulmonary artery wedge pressure measurement by nurses in intensive care units.
    Wiener B; Chacko S; Cron SG; Cohen MZ
    Dimens Crit Care Nurs; 2007; 26(6):263-8. PubMed ID: 18090148
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Measurement of pulmonary artery occlusion (wedge) pressure using the Swan-Ganz catheter: various pitfalls].
    Jolliet P; Chevrolet JC
    Schweiz Med Wochenschr; 1992 Sep; 122(38):1394-401. PubMed ID: 1411397
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Failure of a brief educational program to improve interpretation of pulmonary artery occlusion pressure tracings.
    Zarich S; Pust-Marcone J; Amoateng-Adjepong Y; Manthous CA
    Intensive Care Med; 2000 Jun; 26(6):698-703. PubMed ID: 10945386
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Errors in the measurement and interpretation of pulmonary artery pressure values evaluated by the Swan-Ganz method].
    Wattrisse G; Lecoutre D; Groux-Pante C; Dufossez F
    Cah Anesthesiol; 1993; 41(1):11-7. PubMed ID: 8490743
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of a radiofrequency-based wireless pressure sensor to swan-ganz catheter and echocardiography for ambulatory assessment of pulmonary artery pressure in heart failure.
    Verdejo HE; Castro PF; Concepción R; Ferrada MA; Alfaro MA; Alcaíno ME; Deck CC; Bourge RC
    J Am Coll Cardiol; 2007 Dec; 50(25):2375-82. PubMed ID: 18154961
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pulmonary artery pressure measurement: state of the art.
    Bridges EJ; Woods SL
    Heart Lung; 1993; 22(2):99-111. PubMed ID: 8449767
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wedging the pulmonary artery catheter: changes in left atrial and pulmonary artery pressures and risk for perforation.
    Settergren G; Angdin M; Anderson RE; Liska J; Lundberg J; Törnberg DC; Weitzberg E
    J Cardiothorac Vasc Anesth; 2006 Jun; 20(3):311-4. PubMed ID: 16750728
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements.
    Cannesson M; Attof Y; Rosamel P; Joseph P; Bastien O; Lehot JJ
    Eur J Anaesthesiol; 2007 Oct; 24(10):832-9. PubMed ID: 17666154
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Invasive intravascular hemodynamic monitoring: technical issues.
    Magder S
    Crit Care Clin; 2007 Jul; 23(3):401-14. PubMed ID: 17900478
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Telemetric catheter-based pressure sensor for hemodynamic monitoring: experimental experience.
    Mahnken AH; Urban U; Fassbender H; Schnakenberg U; Schoth F; Schmitz-Rode T
    Cardiovasc Intervent Radiol; 2009 Jul; 32(4):714-9. PubMed ID: 19340482
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Continuous cardiac index monitoring: A prospective observational study of agreement between a pulmonary artery catheter and a calibrated minimally invasive technique.
    McCoy JV; Hollenberg SM; Dellinger RP; Arnold RC; Ruoss L; Lotano V; Peters P; Parrillo JE; Trzeciak S
    Resuscitation; 2009 Aug; 80(8):893-7. PubMed ID: 19520480
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis.
    Biais M; Nouette-Gaulain K; Cottenceau V; Vallet A; Cochard JF; Revel P; Sztark F
    Anesth Analg; 2008 May; 106(5):1480-6, table of contents. PubMed ID: 18420863
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pulmonary artery pressure monitoring.
    Gardner PE
    AACN Clin Issues Crit Care Nurs; 1993 Feb; 4(1):98-119. PubMed ID: 8452747
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of correlation between vascular pedicle width and intravascular volume status in Thai critically ill patients.
    Wichansawakul S; Vilaichone W; Tongyoo S; Permpikul C; Wonglaksanapimol S; Daengnim K; Suwanboonrit G
    J Med Assoc Thai; 2011 Feb; 94 Suppl 1():S181-7. PubMed ID: 21721445
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intensive care telemedicine: evaluating a model for proactive remote monitoring and intervention in the critical care setting.
    Groves RH; Holcomb BW; Smith ML
    Stud Health Technol Inform; 2008; 131():131-46. PubMed ID: 18305328
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery.
    Breukers RM; Sepehrkhouy S; Spiegelenberg SR; Groeneveld AB
    J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):632-5. PubMed ID: 17905265
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The pulmonary artery catheter: in medio virtus.
    Vincent JL; Pinsky MR; Sprung CL; Levy M; Marini JJ; Payen D; Rhodes A; Takala J
    Crit Care Med; 2008 Nov; 36(11):3093-6. PubMed ID: 18824901
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulmonary artery wedge pressure--when it's valid, when it's not.
    Enger EL
    Crit Care Nurs Clin North Am; 1989 Sep; 1(3):603-18. PubMed ID: 2684245
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.